Interactive Catalog Replaces Catalog Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive Catalog. The Interactive Catalog is a power search tool that makes it easier to find product information. It includes more installation, application, and technical information than ever before. Sensing and Control Honeywell Inc. 11 West Spring Street Freeport, Illinois 61032 Click this icon to try the new Interactive Catalog. Pressure Sensors Absolute, Differential, Gage, Vacuum Gage/Amplified 140PC Series FEATURES 1 PCB terminals on opposite side from the ports 1 Fully signal conditioned 140PC SERIES PERFORMANCE CHARACTERISTICS at 8.0 0.01 VDC Excitation, 25C Typ. Max. Units Excitation 7.00 8.00 16.0 VDC Supply Current --- 8.00 20.0 mA Current Sourcing Output --- --- 10 mA Null Offset (141/142PC) 0.95 1.00 1.05 V Null Offset (143PC) * 3.45 3.50 3.55 V Null Offset 142PC15A @ 2 psia 142PC30A @ 2 psia 1.62 1.28 1.67 1.33 1.72 1.38 V V Output at Full Pressure 5.90 6.00 6.10 V Span (141/142PC) 4.95 5.00 5.05 V Span (143PC) * --- 5.00 --- V Span 142PC15A (2 to 15 psia) 142PC30A (2 to 30 psia) 4.28 4.62 4.33 4.67 4.48 4.72 V V Ratiometricity Error 7 to 8 V or 8 to 9 V 9 to 12 V ----- 0.50 2.00 ----- % Span Stability over One Year --- 0.50 --- % Span Response Time --- --- 1.00 msec Common Mode Pressure * * --- --- 40 psi Weight --- 28 --- grams Short Circuit Protection Output may be shorted indefinitely to ground Output Ripple None, DC device Ground Reference Supply and output are common Amplified Min. *Positive and negative pressure measurement. **Higher common mode pressures possible if sensor is not used over entire operating temperature range. Span is defined as the algebraic difference between end points. Please note: actual output is 1 V to 6 V (at 8.00 0.01 VDC). Span is then 5V. ENVIRONMENTAL SPECIFICATIONS Operating Temperature -40 to +85C (-40 to +185F) Storage Temperature -55 to +125C (-67 to +257F) Compensated Temperature -18 to +63C (0 to +145F) Shock MIL-STD-202, Method 213 (50 g, half sine, 6 msec) Vibration MIL-STD-202, Method 204 (10 to 2000 Hz at 10 g) Media P2 port Wetted materials; polyester housing, epoxy adhesive, silicon, borosilicate glass, and silicon-toglass bond* P1 port Dry gases only *Liquid media containing some highly ionic solutions could potentially neutralize the chip-to-glass tube bond. Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 37 Pressure Sensors Absolute, Differential, Gage, Vacuum Gage/Amplified 140PC Series 140PC SERIES ORDER GUIDE, VACUUM GAGE TYPE Shift Null, Sensitivity, Combined** 25 to 5 25 to 45C Linearity, B.F.S.L. P2 > P1 P2 < P1 Repeatability & Hysteresis %Span Typ. 25 to -18 25 to +63C 25 to -40 25 to 85C Max. Max. Max. Sensitivity V/psi Overpressure psi Max. Max. Max. --- 1.50 --- --- 5.000 20 --- 0.75 0.30 0--5 0.50 --- 1.00 2.00 1.000 20 --- 0.75 0.25 0--15 0.50 --- 1.00 2.00 0.333 45 --- 0.40 0.15 Catalog Listing Pressure Range psi Typ. 141PC01G 0--1 141PC05G 141PC15G %Span 140PC SERIES ORDER GUIDE, GAGE TYPE Shift Null, Sensitivity, Combined** 25 to 5 25 to 45C Linearity, B.S.F.L. Max. Max. Repeatability & Hysteresis %Span Typ. 20 0.75 --- 0.30 25 to -18 25 to +63C 25 to -40 25 to 85C Max. Max. Max. Sensitivity V/psi Overpressure psi Max. --- 1.50 --- --- 5.000 Catalog Listing Pressure Range psi Typ. 142PC01G 0-1 P2 > P1 P2 < P1 %Span 142PC02G 0-2 --- 1.50 --- --- 2.500 20 0.75 --- 0.30 142PC05G 0-5 0.50 --- 1.00 2.00 1.000 20 1.50 --- 0.25 142PC15G 0-15 0.50 --- 1.00 2.00 0.333 45 0.75 --- 0.15 142PC30G 0-30 0.50 --- 1.00 2.00 0.167 60 0.75 --- 0.15 143PC03G 2.5 --- --- 1.00 1.50 1.000 20 0.75 --- 0.25 143PC05G 5 --- --- 1.00 1.50 0.500 30 0.75 --- 0.15 143PC15G 15 --- --- 1.00 1.50 0.177 50 0.75 --- 0.15 140PC SERIES ORDER GUIDE, DIFFERENTIAL TYPE Shift Null, Sensitivity, Combined** 25 to 5 25 to 45C Linearity, B.F.S.L. P2 > P1 P2 < P1 Repeatability & Hysteresis %Span Typ. 25 to -18 25 to +63C 25 to -40 25 to 85C Max. Max. Max. Sensitivity V/psi Overpressure psi Max. --- 1.50 --- --- 5.000 0-2 --- 1.50 --- --- 142PC05D 0-5 0.50 --- 1.00 142PC15D 0-15 0.50 --- 1.00 142PC30D 0-30 0.50 --- 1.00 143PC03D 2.5 --- --- 1.00 1.50 1.000 20 0.75 0.40 0.25 143PC05D 5 --- --- 1.00 1.50 0.500 30 0.75 0.40 0.15 143PC15D 15 --- --- 1.00 1.50 0.177 50 0.75 0.40 0.15 Catalog Listing Pressure Range psi Typ. 142PC01D 0-1 142PC02D %Span Max. Max. 20 0.75 0.40 0.30 2.500 20 0.75 0.40 0.30 2.00 1.000 20 1.50 0.75 0.25 2.00 0.333 45 0.75 0.40 0.15 2.00 0.167 60 0.75 0.40 0.15 140PC SERIES ORDER GUIDE, ABSOLUTE TYPE* Shift Null, Sensitivity, Combined** Linearity, B.F.S.L. 25 to -18 25 to +63C 25 to -40 25 to 85C Max. Max. Max. Sensitivity V/psi Overpressure psi Max. Max. Max. Repeatability & Hysteresis %Span Typ. 0.50 --- 1.00 2.00 0.333 45 --- 0.40 0.15 0.50 --- 1.00 2.00 0.167 60 --- 0.40 0.15 25 to 5 25 to 45C Catalog Listing Pressure Range psia Typ. 142PC15A 0-15 142PC30A 0-30 P2 > P1 P2 < P1 %Span *Tested at 2 psia reference **% Span specification applies to each shift independently. (Null, sensitivity, or combined). 38 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Pressure Sensors Absolute, Differential, Gage, Vacuum Gage/Amplified ELECTRICAL CONNECTION Voltage Excitation NULL AND SENSITIVITY TEMPERATURE SHIFT Amplified pressure sensors are 100% tested to insure that the maximum null and sensitivity temperature shift does not exceed the specification. The diagram below illustrates how null and sensitivity shift relates to temperature. Note that the maximum shift occurs at temperature extremes. Therefore, if a sensor is not ex- 140PC Series posed to the entire temperature range, the maximum null and sensitivity shift will actually be less than the value specified. This diagram indicates the temperature shift pertaining to a few listings. Maximum null and sensitivity shift varies from listing to listing. Amplified NOTES 1. Terminals are labeled on the sensor. 2. Input and output share a common ground. 3. RL must be greater than or equal to 3000 ohms. INTERNAL CIRCUITRY RATIOMETRICITY SCALING OF 140PC SERIES SENSORS WITH 8V EXCITATION Ratiometricity refers to the output voltage being directly proportional to the supply voltage. 140PC sensors in this catalog are calibrated at 8 VDC supply voltage to provide a 1-6 volt (5V Span) output swing. For example, if supply increases by 50% to 12 VDC, the output voltage increases by 50% to 1.5-9 volts (7.5 V Span). 142PC15A Absolute 142PC30A Absolute VO J 1 V at 0 psia & 6 V at 30 psia 142PC15G Gage VO J 1 V at 0 psig & 6 V at 15 psig 141PC15G Vacuum Gage VO J 1 V at 0 psig & 6 V at -15 psig 143PC05D Differential VO J 1 V at -5 psig & 6 V at 5 psig 143PC15D Differential VO J 1 V at -15 psig & 6 V at 15 psig NOTE The output is not perfectly ratiometric. See specifications for the degree of error. VO J 1 V at 0 psia & 6 V at 15 psia NOTE: 141PC sensors are scaled for vacuum pressure on P2. 142PC sensors are scaled for greater pressure on the P2 side of the chip. Input pressures on absolute units are applied to the P1 port. Other scalings available upon request. Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 39 Pressure Sensors Absolute, Differential, Gage, Vacuum Gage/Amplified 140PC Series MOUNTING DIMENSIONS (For reference only) Dimensions shown apply to Differential and Absolute versions. Gage units are identical, except the P1 port is absent. 140PC CONSTRUCTION 40 Honeywell 1 MICRO SWITCH Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada