Total Power Part No. Dimensions
Single Outputs: 50-200W VI-LC 8.6" x 2.5" x 0.99"
(218,4 x 63,5 x 25,2mm)
100-400W VI-MC 8.6" x 4.9" x 0.99"
(218,4 x 124,5 x 25,2mm)
300-600W VI-NC 8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
Dual Outputs: 100-400W VI-PC 8.6" x 4.9" x 0.99"
(218,4 x 124,5 x 25,2mm)
150-600W VI-QC 8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
Triple Outputs: 150-600W VI-RC 8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
Product Highlights
ComPAC delivers up to 600W from
one, two, or three outputs in a package
just 0.99” (25,2mm) in height with the
field proven performance, high
efficiency and high reliability inherent
in Vicor’s component level power
converters. ComPAC meets British
Telecom and European norms for input
surge withstand and meets conducted
emissions of EN55022 Class B.
ComPAC is offered with input voltage
ranges optimized for industrial and
telecommunication applications and
provides extended input overvoltage
capability, input reverse polarity
protection, undervoltage lockout, and
master disable.
Features
Inputs 24, 48, and 300Vdc
Any output: 1 to 95Vdc
Input surge withstand:
British Telecom BTR 2511,
EN-61000-4-5
Meets British Telecom BTR 2511,
EN55022 Class B conducted emissions
UL, CSA, TÜV (IEC 950)
CE marked
80-90% efficiency
Up to 10W/cubic inch
Reverse polarity protected
Master disable
Overvoltage shutdown
DC-DC Switchers
50 to 600W
1-3 Outputs
Input Voltage
Nominal Range
1 = 24V 21 - 32V (1)
W = 24V 18 - 36V (1)
3 = 48V 42 - 60V (2)
N = 48V 36 - 76V (2)
6 = 300V 200 - 400V (2)
Output Voltage
Z 2V M 10V K 40V
Y 3.3V 1 12V 4 48V
0 5V P 13.8V H 52V
X 5.2V 2 15V F 72V
W 5.5V N 18.5V D 85V
V 5.8V 3 24V B 95V
T 6.5V L 28V
R 7.5V J 36V
Output Power/Current
Vout 5V Vout < 5V
W = 100W 20A
V = 150W 30A
U = 200W 40A
S = 300W 60A
Q = 400W 80A
Output Power/Current
Vout 5V Vout < 5V
S = 300W 60A
P = 450W 90A
M = 600W 120A
Product Grade
E = -10°C to +85°C
C = -25°C to +85°C
I = -40°C to +85°C
M = -55°C to +85°C
Output Power/Current
Vout 5V Vout < 5V
Y = 50W 10A
X = 75W 15A
W = 100W 20A
V = 150W 30A
U = 200W 40A
ComPAC Configuration Chart
Use the configuration chart at the right to define your
Vicor part number(s).
ComPAC
Max 5V <5V
output for Outputs Outputs
(1) 150W 30A
(2) 200W 40A
Conduction Cooled Models Available
Add "-CC" to the end of the part number.
(Consult factory for details.)
Long Term Safe Operating Area Curves (1% duty cycle max. Zs=0.5Ω; for short duration transient capability refer to page 3.)
0.1 1 10ms 100 1000
800V
Normal Operating Area
I.S.W.
Full Load
300V Input
S.D.
R.E.
500V
400V
200V
500ms
276V
Normal Operating Area
I.S.W.
Full Load
0.1 1 10ms 100 1000
48V Wide Range Input
R.E.
76V
125V
36V S.D.
S.D. 100V
500ms
0.1 1 10ms 100 1000
100V
Normal Operating Area
I.S.W.
Full Load
100V
Standard Wide Range
24V Inputs
R.E.
32V
21V
36V
18V
S.D.
160V
0.1 1 10ms 100 1000
Normal Operating Area
I.S.W.
Full Load
48V Input
R.E.
S.D.
60V
100V
42V
I.S.W.: Input surge withstand, no degradation of per formance. R.E.: Ratings Exceeded S.D.: Shutdown
ComPAC 10/02 1 of 4
ComPAC Specifications
(Typical at 25°C, nominal line and 75% load, unless otherwise specified)
E-GRADE C-, I-, M-GRADE
PARAMETER MIN TYP MAX MIN TYP MAX BROWNOUT* TRANSIENT** UNITS NOTES
Input Characteristics
24V 21 24 32 21 24 32 18 36 Vdc See Fusing Information below
24V Wide 18 24 36 18 24 36 n/a n/a Vdc See Fusing Information below
48V 42 48 60 42 48 60 36 72 Vdc See Fusing Information below
48V Wide 36 48 76 36 48 76 n/a n/a Vdc See Fusing Information below
300V 200 300 400 200 300 400 170 425 Vdc See Fusing Information below
No load power dissipation31.35 2 1.35 2 Watts
Master disable input current34 4 mA Sink or source into disable
(Absolute max., 20 mA) optocoupler
Quiescent Input current
logic disable37 10 7 10 mA Current drawn from source
when disabled
Reverse polarity protection No damage to unit with
external fuse
Output Characteristics (applies to each output individually)
Setpoint accuracy 1% 2% 0.5% 1% VNOM
Load/line regulation 0.5% 0.05% 0.2% VNOM LL to HL, 10% to full load
Load/line regulation 1% 0.2% 0.5% VNOM LL to HL, no load to full load
Output temperature drift 0.02 0.01 0.02 %/°C Over rated temperature
Long term drift 0.02 0.02 %/1k hours
Output ripple
2V, 3.3V 150mV 60mV 100mV Vp-p 20 MHz bandwidth
5V 5% 2% 3% Vp-p 20 MHz bandwidth
10-48V 3% 0.75% 1.5% Vp-p 20 MHz bandwidth
Output voltage trimming150% 110% 50% 110%
Total remote sense
compensation10.5 0.5 Volts 0.25V max. neg. leg
OVP set point 125% 115% 125% 135% VNOM Recycle power
Current limit 105% 135% 105% 125% INOM Automatic restart
Short circuit current220% 140% 20% 130% INOM
Thermal Characteristics
Efficiency 78-88% 80-90% @5V and higher
Shutdown temp. case 90 95 105 90 95 105 °C Cool and recycle power to restart
Operating temp. case 85 85 °C See Thermal Curves
Isolation Characteristics
Isolation
Input to output 4,242 4,242 Vdc
Output to case 707 707 Vdc
Input to case 2,121 2,121 Vdc
Mechanical Specifications
Weight319.2 (544) 19.2 (544) Ounces (Grams)
Fusing Information
Input voltage 24V 48V 300V
LC series (200W) 10A 7A 2A
MC, PC series (400W) 20A 15A 4A
NC, QC, RC series (600W) 35A 25A 6A
Safety Agency Approvals
UL, CSA, TÜV, VDE, IEC 950, CE Marked
Environmental Characteristics/Product Grade Designators (Temperatures apply to product case.)
E-Grade C-Grade I-Grade M-Grade
Storage temperature -20°C to +100°C -40°C to +100°C -55°C to +100°C -65°C to +100°C
Operating temperature -10°C to +85°C -25°C to +85°C -40°C to +85°C -55°C to +85°C
EMI/EMC Characteristics (Performed on selected samples representative of the ComPac product family.)
Input surge withstand (Up to 200 mS, Zs= .5, no interruption of performance, see: Long Term Safe Operating Area Cur ves, pg.2)
IEC 61000-4-5 level 2
Conducted Emissions British Telecom BTR 2511, Issue 2
EN 55022, class B
ESD IEC 61000-4-2 level 4
*Brownout 75% of rated load.
**Transient voltage for one second.
110V, 12V and 15V outputs, trim range ± 10%. Consult factor y for wider trim range.
2Output voltages of 5V or less incorporate foldback current limiting, outputs greater than 5V incorporate straight line current limiting.
3For MC, PC ser ies, multiply by 2; for NC, QC, RC series, multiply by 3.
ComPAC 10/02 2 of 4
Thermal Curves, 5V Output (Standard heatsink)
Thermal Curves, 10V to 48V Output (Standard heatsink)
0
25
50
75
100
125
150
175
200
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
0
50
100
150
200
250
300
350
400
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
0
75
150
225
300
375
450
525
600
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
0
25
50
75
100
125
150
175
200
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
0
50
100
150
200
250
300
350
400
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
0
75
150
225
300
375
450
525
600
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
FREE AIR 50 LFM 100 LFM 250 LFM 500 LFM 750 LFM 1000 LFM
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C) Ambient Temperature (Deg. C) Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
LC Series MC, PC Series NC, QC, RC Series
LC Series MC, PC Series NC, QC, RC Series
Ambient Temperature (Deg. C)
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
FREE AIR 50 LFM 100 LFM 250 LFM 500 LFM 750 LFM 1000 LFM
Thermal Curves, 5V Output (H1 heatsink)
Thermal Curves, 10 to 48V Output (H1 heatsink)
0
75
150
225
300
375
450
525
600
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
0
25
50
75
100
125
150
175
200
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
0
50
100
150
200
250
300
350
400
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
0
75
150
225
300
375
450
525
600
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
0
25
50
75
100
125
150
175
200
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
0
50
100
150
200
250
300
350
400
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (Deg. C)
Output Power (Watts)
Ambient Temperature (Deg. C) Ambient Temperature (Deg. C) Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
Ambient Temperature (Deg. C)
LC Series MC, PC Series NC, QC, RC Series
LC Series MC, PC Series NC, QC, RC Series
FREE AIR 50 LFM 100 LFM 250 LFM 500 LFM 750 LFM 1000 LFM
FREE AIR 50 LFM 100 LFM 250 LFM 500 LFM 750 LFM 1000 LFM
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
Output Power (Watts)
ComPAC 10/02 3 of 4
Mechanical Drawings
OPTIONAL HEATSINK (H1)
STANDARD UNITS
1.12
(28,4)
1.37
(34,80)
0.99
(25,15) 0.5
(12,57)
0.41
(10,4)
9.25±.120
(235,0 ±3,05)
8.63±.025
(219,2±,64)
INPUTS
1 Ground
2 -Input
3 +Input
4 Disable-
5 Disable+
OUTPUTS
A +Output
B +Sense
C Trim
D -Sense
E -Output
0.5
(12,57)
Measure case temperature on this surface.
0.41 (10,41)
2.11 (53,59)
1.53 (38,86)
1.14 (28,96)
0.75 (19,05)
12
ø0.150 ± 0.005 THRU 4 PLACES
(ø3,81 ± 0,13)
0
1
23
4
5
2.156
(54,76)
0.18
(4,6) 2.76
(70,1)
6.00
(152,4)
0.91
23,1)
2.54
(64,5)
0.20
(5,1)
0.19
(4,8)
0.20
(5,1) E
D
C
B
A
0.25 TYP
#8-32 STUD
2 PLACES
OUTPUT 1
(
0.41 (10,41)
4.53 (115,06)
3.95 (100,33)
3.56 (90,42)
3.17 (80,52)
2.83 (71,88)
2.11 (53,59)
1.53 (38,86)
1.14 (28,96)
0.75 (19,05)
12
ø0.150 ± 0.005 THRU 5 PLACES
(ø3,81 ± 0,13) #10-32 STUD
2 PLACES
1
2
3
4
5
3.58
(90,9)
3.04
(77,2)
4.96
(126,0) 4.562
(115,87)
0.18
(4,6) 6.00
(152,4) 2.76
(70,1)
2.281
(57,94)
0.20
(5,1)
0.19
(4,8)
#8-32 STUD
4 PLACES
A
E
D
C
B
A
E
D
C
B
4.
0
0.25 TYP
A
E
D
C
B
OUTPUT 1 OUTPUT 2
OUTPUT 1
All Models
LC Series
MC, PC Series
NC, QC, RC Series
Standard Heatsink
Optional Heatsink (H1)
ComPAC 10/02 4 of 4