Power Distribution Blocks 600 Volts AC/DC Power Blocks Specifications: *Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire * CU Connector, High Conductive Copper, Tin Plated, Rated for Copper Wire Only * Multiple wire rating - refer to datasheets for details * UL Recognized File No. XCFR2.E62806 * CSA Certified File No. LR19766 * - Up to 1000 Volts AC/DC * Flexible Stranded Wire Compliant * RoHS Compliant 1423570 1414400 Replace "X" with # of poles (0 = Adder) MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. LINE SIDE Wire Range AWG/kcmil LOAD SIDE Openings Connector Per Pole Configuration Wire Range AWG/kcmil Openings Connector Per Pole Configuration 141X403 1/2/3/4 60 Plastic AL #2 - #14 AWG 1 #10 - #16 AWG 2 141X400 1/2/3/4 115 Plastic AL #2 - #14 AWG 1 #10 - #18 AWG 4 0/1/2/3 175 Plastic AL 2/0 - #14 AWG 1 #4 - #14 AWG 4 1/2/3 175 Phenolic AL 2/0 - #14 AWG 1 #4 - #14 AWG 4 0/1/2/3 175 Plastic AL 2/0 - #14 AWG 1 #4 - #14 AWG 6 140X402 2/3 175 Phenolic AL 2/0 - #14 AWG 1 #4 - #14 AWG 4 140X401 2/3 175 Phenolic AL 2/0 - #14 AWG 1 #4 - #14 AWG 6 0/1/2/3 175 Plastic CU 2/0 - #14 AWG 1 #4 - #14 AWG 4 142X970 1/2/3 175 Phenolic CU 2/0 - #14 AWG 1 #4 - #14 AWG 4 140X404 2/3 310 Phenolic AL 350 kcmil - #6 AWG 1 #4 - #14 AWG 6 1/2/3 310 Plastic AL 350 kcmil - #6 AWG 1 2/0 - #14 AWG 2 2/3 310 Phenolic AL 350 kcmil - #6 AWG 1 2/0 - #14 AWG 2 132X570 CH 142X570 132X580 132X970 133X554 140X410 CH CH CH CH = Block is also available with hinge cover attached - include "CH" at end of part number when ordering (not available on Adder blocks) - See page 58 for available covers 44 See pages 55-57 for dimensional information Datasheets available at marathonsp.com Power Distribution Blocks 600 Volts AC/DC Specifications: Power Blocks *Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire * CU Connector, High Conductive Copper, Tin Plated, Rated for Copper Wire Only * Multiple wire rating - refer to datasheets for details * UL Recognized File No. XCFR2.E62806 * CSA Certified File No. LR19766 * - Up to 1000 Volts AC/DC * Flexible Stranded Wire Compliant * RoHS Compliant 1443560 1433553 Replace "X" with # of poles MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. LINE SIDE Wire Range AWG/kcmil Openings Connector Per Pole Configuration LOAD SIDE Wire Range AWG/kcmil Openings Connector Per Pole Configuration 143X554 1/2/3 310 Phenolic AL 350 kcmil - #6 AWG 1 2/0 - #14 AWG 2 144X401 1/2/3 335 Phenolic AL 400 kcmil - #6 AWG 1 #2 - #14 AWG 6 143X552 1/2/3 335 Phenolic AL 400 kcmil - #6 AWG 1 #2 - #14 AWG 4 143X553 1/2/3 335 Phenolic AL 400 kcmil - #6 AWG 1 #2 - #14 AWG 6 144X560 1/2/3 335 Phenolic AL 400 kcmil - #6 AWG 1 #2 - #14 AWG 8 1/2/3 335 Plastic AL 400 kcmil - #6 AWG 1 #2 - #14 AWG 4 1/2/3 350 Phenolic AL 2/0 - #14 AWG 2 #4 - #14 AWG 6 1/2/3 350 Plastic AL 2/0 - #14 AWG 2 #4 - #14 AWG 6 1/2/3 350 Phenolic CU 2/0 - #14 AWG 2 #4 - #14 AWG 6 1/2/3 350 Plastic CU 2/0 - #14 AWG 2 #4 - #14 AWG 6 1/2/3 380 Phenolic CU 500 kcmil - #4 AWG 1 #2 - #14 AWG 6 133X552 CH 143X555 133X555 CH 143X955 133X955 143X953 CH CH = Block is also available with hinge cover attached - include "CH" at end of part number when ordering (not available on Adder blocks) - See page 58 for available covers Datasheets available at marathonsp.com 45 See pages 55-57 for dimensional information Power Distribution Blocks (cont.) 600 Volts AC/DC Power Blocks Specifications: *Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire * CU Connector, High Conductive Copper, Tin Plated, Rated for Copper Wire Only * Multiple wire rating - refer to datasheets for details * UL Recognized File No. XCFR2.E62806 * CSA Certified File No. LR19766 * - Up to 1000 Volts AC/DC * Flexible Stranded Wire Compliant * RoHS Compliant 1333588 CH 1333595 CH Replace "X" with # of poles LINE SIDE MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. Wire Range AWG/kcmil LOAD SIDE Openings Connector Per Pole Configuration Wire Range AWG/kcmil Openings Connector Per Pole Configuration 1/2/3 380 Plastic CU 500 kcmil - #4 AWG 1 #2 - #14 AWG 6 144X551 1/2/3 380 Phenolic AL 500 kcmil - #4 AWG 1 #2 - #14 AWG 6 145X579 1/2/3 380 Phenolic AL 500 kcmil - #4 AWG 1 2/0 - #14 AWG 6 1/2/3 380 Plastic AL 500 kcmil - #4 AWG 1 #2 - #14 AWG 350 kcmil - #6 AWG 3 1 143X587 1/2/3 380 Phenolic AL 500 kcmil - #4 AWG 1 #2 - #14 AWG 350 kcmil - #6 AWG 3 1 145X594 1/2/3 380 Phenolic AL 500 kcmil - #4 AWG 1 #2 - #14 AWG 8 145X552 1/2/3 380 Phenolic AL 500 kcmil - #4 AWG 1 #2 - #14 AWG 12 133X953 133X587 CH CH 133X588 CH 1/2/3 420 Plastic AL 600 kcmil - #2 AWG 1 #2 - #14 AWG 1/0 - #14 AWG 6 3 133X595 CH 1/2/3 420 Plastic AL 600 kcmil - #2 AWG 1 4 - #14 AWG 12 133X585 CH 1/2/3 420 Plastic AL 600 kcmil - #2 AWG 1 2 - #14 AWG 8 133X575 CH 1/2/3 420 Plastic AL 600 kcmil - #2 AWG 1 2/0 - #14 AWG 4 133X565 CH 1/2/3 420 Plastic AL 600 kcmil - #2 AWG 1 250 kcmil - #6 AWG 2 CH = Block is also available with hinge cover attached - include "CH" at end of part number when ordering - See page 58 for available covers 46 See pages 55-57 for dimensional information Datasheets available at marathonsp.com Power Distribution Blocks (cont.) 600 Volts AC/DC Specifications: Power Blocks *Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire * CU Connector, High Conductive Copper, Tin Plated, Rated for Copper Wire Only * Multiple wire rating - refer to datasheets for details * UL Recognized File No. XCFR2.E62806 * CSA Certified File No. LR19766 * - Up to 1000 Volts AC/DC * Flexible Stranded Wire Compliant * RoHS Compliant 1333596 CH 1333598 CH Replace "X" with # of poles LINE SIDE MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. Wire Range AWG/kcmil Connector Openings Per Pole Configuration LOAD SIDE Wire Range AWG/kcmil Openings Connector Per Pole Configuration 133X596 CH 1/2/3 510 Plastic AL 250 kcmil - 1/0 AWG 2 #4 - #14 AWG 12 133X597 CH 1/2/3 510 Plastic AL 250 kcmil - 1/0 AWG 2 #2 - #14 AWG 8 133X598 CH 1/2/3 510 Plastic AL 250 kcmil - 1/0 AWG 2 2/0 - #14 AWG 4 145X587 1/2/3 690 Phenolic AL 500 kcmil - #4 AWG 350 kcmil - #4 AWG 1 1 2/0 - #14 AWG 4 145X592 1/2/3 760 Phenolic AL 500 kcmil - #4 AWG 2 #4 - #14 AWG 12 145X586 1/2/3 760 Phenolic AL 500 kcmil - #6 AWG 2 2/0 - #14 AWG 8 145X992 1/2/3 760 Phenolic CU 500 kcmil - #4 AWG 2 #2 - #14 AWG 12 145X986 1/2/3 760 Phenolic CU 500 kcmil - #4 AWG 2 2/0 - #14 AWG 8 145X408 1/2/3 760 Phenolic AL 500 kcmil - #6 AWG 2 #2 - #14 AWG 12 145X411 1/2/3 840 Phenolic AL 600 kcmil - #2 AWG 2 3/0 - #6 AWG #4 - #14 AWG 4 4 1453401* 1 2280 Phenolic AL 500 kcmil - #4 AWG 6 2/0 - #14 AWG 18 CH = Block is also available with hinge cover attached - include "CH" at end of part number when ordering - See page 58 for available covers *Special one-pole block. Apply Power Block Dimensions for 145 Series block on page 57 (3 pole). Datasheets available at marathonsp.com 47 See pages 55-57 for dimensional information Power Terminal Block Dimensions 132 SERIES .89 22.5 1.00 25.5 1.82 46.3 2.42 61.5 .20 5 2.55 64.8 3.00 76.2 SLOT .49 X .22 THRU [12.3 X 5.5] TYP. Adder 132 CH SERIES .81 20.7 TYP. 1 Pole 2 Pole 3 Pole 2.55 64.8 1.82 46.3 1.00 25.5 2.25 57.2 (MTG. SLOTS) 1 Pole 1.96 49.7 4.00 101.6 2.57 65.2 3.00 76.2 .81 20.7 (MTG SLOTS) TYP. 133 SERIES .85 21.6 1.63 41.3 .31 7.9 1.63 41.3 (MTG SLOTS) 2 Pole SLOT .49 X .22 THRU [12.3 X 5.5] TYP. 3 Pole 3.66 92.9 5.36 136.1 SLOT .21 X .71 THRU CB .44 X .94 X .29 DP TYP. 3.38 85.7 .97 24.6 TYP. 1 Pole 133 CH SERIES 1.70 43.2 TYP. 2 Pole 3.40 86.4 3.33 84.6 3 Pole .31 7.9 4.00 101.6 SLOT .21 X .71 THRU CB .44 X .94 X .29 DP TYP. 3.38 85.7 (MTG. SLOTS) 1.70 43.2 (MTG SLOTS) TYP. .97 24.6 TYP. For electronic drawings or 2D/3D CAD data, submit request at www.marathonsp.com/drawings.html 5.36 136.1 3.66 92.9 1.96 49.7 1 Pole Datasheets available at marathonsp.com 2 Pole 55 3.40 86.4 (MTG SLOTS) 3 Pole 3.49 88.6 Power Blocks 2.25 57.2 Power Terminal Block Dimensions 4.13 104.8 140 SERIES 5.38 136.5 2.06 52.3 2.90 73.7 Power Blocks 1.00 25.4 3.38 85.7 4.63 117.5 3.52 89.3 4.77 121 2 Pole 141 SERIES (2)SLOTS .27 X .38 [6.7 X 9.5] (4)SLOTS .22 X .38 [5.5 X 9.5] 3 Pole O .20 THRU TYP. 5.1 .38 9.7 TYP. 1.91 48.5 1.27 32.2 .18 4.6 1.93 49.1 2.29 58.1 1.46 37 2.10 53.2 2.74 69.5 2 Pole 3 Pole 4 Pole .84 21.2 1 Pole 1.53 38.7 142 SERIES 1.13 28.6 1.94 49.2 1.78 45.2 2.75 69.9 2.88 73 2.25 57.2 .56 14.3 .81 20.6 1 Pole 2 Pole 1.62 41.2 .23 5.7 3 Pole For electronic drawings or 2D/3D CAD data, submit request at www.marathonsp.com/drawings.html 56 Datasheets available at marathonsp.com Power Terminal Block Dimensions 143 SERIES 1.94 49.2 3.47 88.1 5.00 127 2.61 66.2 4.00 101.7 .97 24.6 TYP. 1 Pole 1.53 38.9 TYP. 3.06 77.8 2 Pole 3 Pole .23 5.8 O .203 [5.2] THRU CB O .406 [10.3] TYP. 144 SERIES 2.28 57.9 4.16 105.7 6.03 153.2 2.91 73.9 4.13 104.8 TYP. 4.75 120.6 1.14 29 TYP. 1 Pole 145 SERIES 3.17 80.5 1.88 47.6 TYP. 3.75 95.3 2 Pole O .203 [5.2] THRU CB O .406 [10.3] TYP. .33 8.4 3 Pole 5.88 149.2 8.54 216.9 3.13 79.4 4.75 120.7 TYP. 5.50 139.7 1.59 40.3 TYP. 1 Pole 2.69 68.3 TYP. 5.38 136.5 2 Pole 3 Pole For electronic drawings or 2D/3D CAD data, submit request at www.marathonsp.com/drawings.html Datasheets available at marathonsp.com 57 O .265 [6.7] THRU CB O .50 [10.3] TYP. .31 7.7 Power Blocks 3.38 85.9