Single-Channel 1-Wire Master DS2482-100 General Description Benefits and Features The DS2482-100 is an I2C-to-1-Wire(R) bridge device * Allows Easy Interface Between a I2C Microport and a that interfaces directly to standard (100kHz max) or fast (400kHz max) I2C masters to perform bidirectional protocol conversion between the I 2 C master and any downstream 1-Wire slave devices. Relative to any attached 1-Wire slave device, the DS2482-100 is a 1-Wire master. Internal, factory-trimmed timers relieve the system host processor from generating time-critical 1-Wire waveforms, supporting both standard and overdrive 1-Wire communication speeds. To optimize 1-Wire waveform generation, the DS2482-100 performs slew-rate control on rising and falling 1-Wire edges and provides additional programmable features to match drive characteristics to the 1-Wire slave environment. Programmable, strong pullup features support 1-Wire power delivery to 1-Wire devices such as EEPROMs and sensors. The DS2482-100 combines these features with an output to control an external MOSFET for enhanced strong pullup application. The I 2 C slave address assignment is controlled by two binary address inputs, resolving potential conflicts with other I2C slave devices in the system. 1-Wire Slave * I2C Host Interface Supports 100kHz and 400kHz I2C Communication Speeds * 1-Wire Master IO with Selectable Active or Passive 1-Wire Pullup * Provides Reset/Presence, 8-Bit, Single-Bit, and 3-Bit 1-Wire IO Sequences * Standard and Overdrive 1-Wire Communication Speeds * Two Address Inputs for I2C Address Assignment Applications Printers Medical Instruments Industrial Sensors Cell Phones, PDAs * Minimizes Line Noise Reducing System EMI * Slew-Controlled 1-Wire Edges * Supports EEPROMs, Temperature Sensors, or Other 1-Wire Slaves That Have Momentary High Source Current Modes * Strong 1-Wire Pullup Provided by an Internal LowImpedance Signal Path * PCTLZ Output to Optionally Control an External MOSFET for Stronger Pullup Requirements * Operating Range: 2.9V to 5.5V, -40C to +85C * 8-Pin (150 mils) SO and 9-Bump WLP Packages Pin Configurations and Ordering Information appear at end of data sheet. Typical Operating Circuit VCC CURRENT-LIMITING RESISTOR REFER TO APPLICATION NOTE 4206 OPTIONAL CIRCUITRY RP* (I2C PORT) C SDA SCL PCTLZ DS2482-100 AD0 AD1 1-Wire LINE IO 1-Wire DEVICE *RP = I2C PULLUP RESISTOR (SEE THE APPLICATIONS INFORMATION SECTION FOR RP SIZING). 1-Wire is a registered trademark of Maxim Integrated Products, Inc. 19-4930; Rev 10; 1/15 1-Wire DEVICE 1-Wire DEVICE Single-Channel 1-Wire Master DS2482-100 Absolute Maximum Ratings Voltage Range on Any Pin Relative to Ground.........-0.5V to +6V Maximum Current into Any Pin .........................................20mA Operating Temperature Range ...........................-40C to +85C Junction Temperature ......................................................+150C Storage Temperature Range .............................-55C to +125C Lead Temperature (SO only; soldering, 10s)...................+300C Soldering Temperature (reflow) SO, WLP.......................................................................+260C Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Electrical Characteristics (VCC = 2.9V to 5.5V, TA = -40C to +85C.) PARAMETER SYMBOL Supply Voltage VCC Operating Current ICC 1-Wire Input High (Notes 2, 3) VIH1 1-Wire Input Low (Notes 2, 3) VIL1 1-Wire Weak Pullup Resistor RWPU 1-Wire Output Low VOL1 Active Pullup On Time (Notes 4, 5) Strong Pullup Voltage Drop tAPUOT VSTRPU CONDITIONS MIN TYP MAX 3.3V 2.9 3.3 3.7 5V 4.5 5.0 5.5 (Note 1) 1.9 5V 3.4 0.9 5V 1.2 (Note 4) PDSRC Pullup Slew Rate (Note 6) PUSRC Power-On Reset Trip Point VPOR V mA V 3.3V 1000 At 4mA load V 1675 0.4 V Standard 2.3 2.5 2.7 Overdrive 0.4 0.5 0.6 VCC 3.2V, 1.5mA load 0.3 VCC 5.2V, 3mA load 0.5 Standard (3.3V 10%) Pulldown Slew Rate (Note 6) 0.75 3.3V UNITS 1 4.2 Overdrive (3.3V 10%) 5 22.1 Standard (5.0V 10%) 2 6.5 Overdrive (5.0V 10%) 10 40 Standard (3.3V 10%) 0.8 4 Overdrive (3.3V 10%) 2.7 20 Standard (5.0V 10%) 1.3 6 Overdrive (5.0V 10%) 3.4 s V V/s V/s 31 2.2 V 1-Wire TIMING (Note 5) (See Figures 4, 5, and 6) Write-One/Read Low Time tW1L Read Sample Time tMSR 1-Wire Time Slot t SLOT www.maximintegrated.com Standard 7.6 8 8.4 Overdrive 0.9 1 1.1 Standard 13.3 14 15 Overdrive 1.4 1.5 1.8 Standard 65.8 69.3 72.8 Overdrive 9.9 10.5 11.0 s s s Maxim Integrated | 2 Single-Channel 1-Wire Master DS2482-100 Electrical Characteristics (continued) (VCC = 2.9V to 5.5V, TA = -40C to +85C.) PARAMETER SYMBOL CONDITIONS Standard (3.3V to 0V) Fall Time High-to-Low (Notes 6, 7) Write-Zero Low Time tF1 tW0L Write-Zero Recovery Time tREC0 Reset Low Time tRSTL Presence-Detect Sample Time tMSP Sampling for Short and Interrupt tSI Reset High Time tRSTH MIN TYP MAX 0.54 3.0 Overdrive (3.3V to 0V) 0.10 0.59 Standard (5.0V to 0V) 0.55 2.2 Overdrive (5.0V to 0V) 0.09 0.44 Standard 60 64 68 Overdrive 7.1 7.5 7.9 Standard 5.0 5.3 5.6 Overdrive 2.8 3.0 3.2 Standard 570 600 630 Overdrive 68.4 72 75.6 Standard 66.5 70 73.5 Overdrive 7.1 7.5 7.9 Standard 7.6 8 8.4 Overdrive 0.7 0.75 0.8 Standard 554.8 584 613.2 Overdrive 70.3 74 77.7 UNITS s s s s s s s CONTROL PIN (PCTLZ) Output Low Voltage VOLP VCC = 2.9V, 1.2mA load current Output High Voltage VOHP 0.4mA load current 0.4 VCC 0.5V V V I2C PINS (SCL, SDA, AD0, AD1) (Note 8) (See Figure 9) VCC = 2.9V to 3.7V -0.5 0.25 x VCC VCC = 4.5V to 5.5V -0.5 0.22 x VCC VIH 0.7 x VCC VCC + 0.5V Hysteresis of Schmitt Trigger Inputs VHYS 0.05 x VCC Low-Level Output Voltage at 3mA Sink Current VOL Output Fall Time from VIH(MIN) to VIL(MAX) with a Bus Capacitance from 10pF to 400pF t OF Pulse Width of Spikes That Are Suppressed by the Input Filter t SP Input Current Each Input/Output Pin with an Input Voltage Between 0.1 x VCC(MAX) and 0.9 x VCC(MAX) II Low-Level Input Voltage High-Level Input Voltage www.maximintegrated.com VIL 60 SDA and SCL pins only (Notes 9, 10) -10 V V V 0.4 V 250 ns 50 ns +10 A Maxim Integrated | 3 Single-Channel 1-Wire Master DS2482-100 Electrical Characteristics (continued) (VCC = 2.9V to 5.5V, TA = -40C to +85C.) PARAMETER Input Capacitance SCL Clock Frequency Hold Time (Repeated) START Condition (After this period, the first clock pulse is generated.) SYMBOL CI CONDITIONS MIN (Note 9) f SCL 0 tHD:STA 0.6 TYP MAX UNITS 10 pF 400 kHz s Low Period of the SCL Clock tLOW 1.3 s High Period of the SCL Clock tHIGH 0.6 s Setup Time for a Repeated START Condition t SU:STA 0.6 s Data Hold Time tHD:DAT (Notes 11, 12) Data Setup Time t SU:DAT (Note 13) 250 ns Setup Time for STOP Condition t SU:STO 0.6 s Bus Free Time Between a STOP and START Condition tBUF 1.3 s Capacitive Load for Each Bus Line CB (Note 14) 400 pF t OSCWUP (Note 15) 100 s Oscillator Warmup Time Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: Note 8: Note 9: Note 10: Note 11: Note 12: Note 13: Note 14: Note 15: 0.9 s Operating current with 1-Wire write-byte sequence followed by continuously reading the Status Register at 400kHz in overdrive. With standard speed, the total capacitive load of the 1-Wire bus should not exceed 1nF. Otherwise, the passive pullup on threshold VIL1 may not be reached in the available time. With overdrive speed, the capacitive load on the 1-Wire bus must not exceed 300pF. Active pullup guaranteed to turn on between VIL1(MAX) and VIH1(MIN). Active or resistive pullup choice is configurable. Except for tF1, all 1-Wire timing specifications and tAPUOT are derived from the same timing circuit. Therefore, if one of these parameters is found to be off the typical value, it is safe to assume that all these parameters deviate from their typical value in the same direction and by the same degree. These values apply at full load, i.e., 1nF at standard speed and 0.3nF at overdrive speed. For reduced load, the pulldown slew rate is slightly faster. Fall time high-to-low (tF1) is derived from PDSRC, referenced from 0.9 x VCC to 0.1 x VCC. All I2C timing values are referred to VIH(MIN) and VIL(MAX) levels. Applies to SDA, SCL, AD0 and AD1. The input/output pins of the DS2482-100 do not obstruct the SDA and SCL lines if VCC is switched off. The DS2482-100 provides a hold time of at least 300ns for the SDA signal (referred to the VIH(MIN) of the SCL signal) to bridge the undefined region of the falling edge of SCL. The maximum tHD:DAT need only be met if the device does not stretch the low period (tLOW) of the SCL signal. A fast-mode I2C bus device can be used in a standard-mode I2C bus system, but the requirement tSU:DAT 250ns must then be met. This is automatically the case if the device does not stretch the low period of the SCL signal. If such a device does stretch the low period of the SCL signal, it must output the next data bit to the SDA line tR(MAX) + tSU:DAT = 1000 + 250 = 1250ns (according to the standard-mode I2C bus specification) before the SCL line is released. CB--Total capacitance of one bus line in pF. If mixed with high-speed-mode devices, faster fall times according to I2CBus Specification Version 2.1 are allowed. I2C communication should not take place for the max tOSCWUP time following a power-on reset. www.maximintegrated.com Maxim Integrated | 4 Single-Channel 1-Wire Master DS2482-100 Pin Description PIN SO WLP 1 B3 NAME VCC FUNCTION Power-Supply Input 2 C3 IO 3 C2 GND Input/Output Driver for 1-Wire Line Ground Reference 4 B1 SCL I2C Serial Clock Input. Must be connected to VCC through a pullup resistor. 5 B2 SDA I2C Serial Data Input/Output. Must be connected to VCC through a pullup resistor. 6 A1 PCTLZ 7 A2 AD1 8 A3 AD0 Active-Low Control Output for an External p-Channel MOSFET. Provides extra power to the 1-Wire line, e.g., for use with 1-Wire devices that require a higher current temporarily to operate. I2C Address Inputs. Must be connected to VCC or GND. These inputs determine the I2C slave address of the device (see Figure 8). CONFIGURATION REGISTER SDA SCL I2C INTERFACE CONTROLLER T-TIME OSC INPUT/OUTPUT CONTROLLER AD0 AD1 LINE XCVR IO PCTLZ STATUS REGISTER READ DATA REGISTER DS2482-100 Figure 1. Block Diagram Detailed Description The DS2482-100 is a self-timed 1-Wire master that supports advanced 1-Wire waveform features including standard and overdrive speeds, active pullup, and strong pullup for power delivery. The active pullup affects rising edges on the 1-Wire side. The strong pullup function uses the same pullup transistor as the active pullup, but with a different control algorithm. In addition, the strong pullup activates the PCTLZ pin, controlling optional external circuitry to deliver additional power beyond the capabilities of the on-chip pullup transistor. Once supplied with command and data, the input/output controller of the DS2482-100 performs www.maximintegrated.com time-critical 1-Wire communication functions such as reset/presence-detect cycle, read-byte, write-byte, single-bit R/W, and triplet for ROM Search, without requiring interaction with the host processor. The host obtains feedback (completion of a 1-Wire function, presence pulse, 1-Wire short, search direction taken) through the Status Register and data through the Read Data Register. The DS2482-100 communicates with a host processor through its I 2C bus interface in standard mode or in fast mode. The logic state of two address pins determines the I2C slave address of the DS2482-100, allowing up to four devices operating on the same bus segment without requiring a hub. See Figure 1 for a block diagram. Maxim Integrated | 5 Single-Channel 1-Wire Master DS2482-100 Active Pullup (APU) Device Registers The DS2482-100 has three registers that the I2C host can read: Configuration, Status, and Read Data. These registers are addressed by a read pointer. The position of the read pointer, i.e., the register that the host reads in a subsequent read access, is defined by the instruction the DS2482-100 executed last. To enable certain 1-Wire features, the host has read and write access to the Configuration Register. Configuration Register The DS2482-100 supports three 1-Wire features that are enabled or selected through the Configuration Register. These features are: * Active Pullup (APU) * Strong Pullup (SPU) * 1-Wire Speed (1WS) These features can be selected in any combination. While APU and 1WS maintain their state, SPU returns to its inactive state as soon as the strong pullup has ended. After a device reset (power-up cycle or initiated by the Device Reset command), the Configuration Register reads 00h. When writing to the Configuration Register, the new data is accepted only if the upper nibble (bits 7 to 4) is the one's complement of the lower nibble (bits 3 to 0). When read, the upper nibble is always 0h. The APU bit controls whether an active pullup (controlled slew-rate transistor) or a passive pullup (RWPU resistor) is used to drive a 1-Wire line from low to high. When APU = 0, active pullup is disabled (resistor mode). Active pullup should always be selected unless there is only a single slave on the 1-Wire line. The active pullup does not apply to the rising edge of a presence pulse or a recovery after a short on the 1-Wire line. The circuit that controls rising edges (Figure 2) operates as follows: At t1, the pulldown (from DS2482-100 or 1-Wire slave) ends. From this point on, the 1-Wire bus is pulled high through R WPU internal to the DS2482-100. VCC and the capacitive load of the 1-Wire line determine the slope. In case that active pullup is disabled (APU = 0), the resistive pullup continues, as represented by the solid line. With active pullup enabled (APU = 1), and when at t2 the voltage has reached a level between VIL1(MAX) and VIH1(MIN), the DS2482-100 actively pulls the 1-Wire line high, applying a controlled slew rate as represented by the dashed line. The active pullup continues until tAPUOT is expired at t3. From that time on the resistive pullup continues. See the Strong Pullup (SPU) section for a way to keep the pullup transistor conducting beyond t3. Configuration Register Bit Assignment BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 1WS SPU 1 APU 1WS SPU 0 APU VCC APU = 1 APU = 0 VIH1(MIN) VIL1(MAX) 0V tAPUOT 1-Wire BUS IS DISCHARGED t1 t2 t3 Figure 2. Rising Edge Pullup www.maximintegrated.com Maxim Integrated | 6 Single-Channel 1-Wire Master DS2482-100 long as the strong pullup is active, the PCTLZ output is low. When the strong pullup ends, the SPU bit is automatically reset to 0. Using the strong pullup feature does not change the state of the APU bit in the Configuration Register. Note: Strong pullup also affects the 1-Wire Reset command. If enabled, it can cause incorrect reading of the presence pulse and may cause a violation of the device's absolute maximum rating. Strong Pullup (SPU) The SPU bit is used to activate the strong pullup function prior to a 1-Wire Write Byte or 1-Wire Single Bit command. Strong pullup is commonly used with 1-Wire EEPROM devices when copying scratchpad data to the main memory or when performing an SHA-1 computation and with parasitically powered temperature sensors or A/D converters. The respective device data sheets specify the location in the communications protocol after which the strong pullup should be applied. The SPU bit must be set immediately prior to issuing the command that puts the 1-Wire device into the state where it needs the extra power. The strong pullup uses the same internal pullup transistor as the active pullup feature. For cases where the internal strong pullup has insufficient strength, the PCTLZ pin can be used to control an external p-channel MOSFET to supply additional power beyond the drive capability of the DS2482-100 to the 1-Wire line. See the V STRPU parameter in the Electrical Characteristics to determine if the internal strong pullup is sufficient given the current load on the device. If SPU is 1, the DS2482-100 treats the rising edge of the time slot in which the strong pullup starts as if the active pullup was activated. However, in contrast to the active pullup, the strong pullup, i.e., the internal pullup transistor, remains conducting, as shown in Figure 3, until one of three events occurs: the DS2482-100 receives a command that generates 1-Wire communication (the typical case); the SPU bit in the Configuration Register is written to 0; or the DS2482-100 receives the Device Reset command. As 1-Wire Speed (1WS) The 1WS bit determines the timing of any 1-Wire communication generated by the DS2482-100. All 1-Wire slave devices support standard speed (1WS = 0), where the transfer of a single bit (tSLOT in Figure 3) is completed within 65s. Many 1-Wire devices can also communicate at a higher data rate, called overdrive speed. To change from standard to overdrive speed, a 1-Wire device needs to receive an Overdrive-Skip ROM or Overdrive-Match ROM command, as explained in the 1-Wire device data sheets. The change in speed occurs immediately after the 1-Wire device has received the speed-changing command code. The DS2482-100 must take part in this speed change to stay synchronized. This is accomplished by writing to the Configuration Register with the 1WS bit as 1 immediately after the 1-Wire Byte command that changes the speed of a 1-Wire device. Writing to the Configuration Register with the 1WS bit as 0, followed by a 1-Wire Reset command, changes the DS2482-100 and any 1-Wire devices on the active 1-Wire line back to standard speed. LAST BIT OF 1-Wire WRITE BYTE OR 1-Wire SINGLE BIT FUNCTION VCC WRITE-ONE CASE WRITE-ZERO CASE NEXT TIME SLOT OR 1-Wire RESET 0V tSLOT PCTLZ DS2482-100 RESISTIVE PULLUP DS2482-100 PULLDOWN DS2482-100 STRONG PULLUP Figure 3. Low-Impedance Pullup Timing www.maximintegrated.com Maxim Integrated | 7 Single-Channel 1-Wire Master DS2482-100 Status Register Bit Assignment BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DIR TSB SBR RST LL SD PPD 1WB Status Register Logic Level (LL) The read-only Status Register is the general means for the DS2482-100 to report bit-type data from the 1-Wire side, 1-Wire busy status, and its own reset status to the host processor. All 1-Wire communication commands and the Device Reset command position the read pointer at the Status Register for the host processor to read with minimal protocol overhead. Status information is updated during the execution of certain commands only. Details are given in the description of the various status bits that follow. The LL bit reports the logic state of the active 1-Wire line without initiating any 1-Wire communication. The 1-Wire line is sampled for this purpose every time the Status Register is read. The sampling and updating of the LL bit takes place when the host processor has addressed the DS2482-100 in read mode (during the acknowledge cycle), provided that the read pointer is positioned at the Status Register. 1-Wire Busy (1WB) The 1WB bit reports to the host processor whether the 1-Wire line is busy. During 1-Wire communication 1WB is 1; once the command is completed, 1WB returns to its default 0. Details on when 1WB changes state and for how long it remains at 1 are found in the Function Commands section. Device Reset (RST) If the RST bit is 1, the DS2482-100 has performed an internal reset cycle, either caused by a power-on reset or from executing the Device Reset command. The RST bit is cleared automatically when the DS2482-100 executes a Write Configuration command to restore the selection of the desired 1-Wire features. Single Bit Result (SBR) The PPD bit is updated with every 1-Wire Reset command. If the DS2482-100 detects a presence pulse from a 1-Wire device at tMSP during the presence-detect cycle, the PPD bit is set to 1. This bit returns to its default 0 if there is no presence pulse or if the 1-Wire line is shorted during a subsequent 1-Wire Reset command. The SBR bit reports the logic state of the active 1-Wire line sampled at tMSR of a 1-Wire Single Bit command or the first bit of a 1-Wire Triplet command. The power-on default of SBR is 0. If the 1-Wire Single Bit command sends a 0 bit, SBR should be 0. With a 1-Wire Triplet command, SBR could be 0 as well as 1, depending on the response of the 1-Wire devices connected. The same result applies to a 1-Wire Single Bit command that sends a 1 bit. Short Detected (SD) Triplet Second Bit (TSB) The SD bit is updated with every 1-Wire Reset command. If the DS2482-100 detects a logic 0 on the 1-Wire line at tSI during the presence-detect cycle, the SD bit is set to 1. This bit returns to its default 0 with a subsequent 1-Wire Reset command provided that the short has been removed. If SD is 1, PPD is 0. The DS2482-100 cannot distinguish between a short and a DS1994 or DS2404 signaling a 1-Wire interrupt. For this reason, if a DS2404 or DS1994 is used in the application, the interrupt function must be disabled. The interrupt signaling is explained in the respective 1-Wire device data sheets. The TSB bit reports the logic state of the active 1-Wire line sampled at t MSR of the second bit of a 1-Wire Triplet command. The power-on default of TSB is 0. This bit is updated only with a 1-Wire Triplet command and has no function with other commands. Presence-Pulse Detect (PPD) www.maximintegrated.com Branch Direction Taken (DIR) Whenever a 1-Wire Triplet command is executed, this bit reports to the host processor the search direction that was chosen by the third bit of the triplet. The power-on default of DIR is 0. This bit is updated only with a 1-Wire Triplet command and has no function with other commands. For additional information, see the description of the 1-Wire Triplet command and Application Note 187: 1-Wire Search Algorithm. Maxim Integrated | 8 Single-Channel 1-Wire Master DS2482-100 Function Commands The DS2482-100 understands eight function commands that fall into four categories: device control, I2C communication, 1-Wire setup, and 1-Wire communication. The feedback path to the host is controlled by a read pointer, which is set automatically by each function command for the host to efficiently access relevant information. The host processor sends these commands and applicable parameters as strings of one or two bytes using the I 2C interface. The I 2C protocol requires that each byte be acknowledged by the receiving party to confirm acceptance or not be acknowledged to indicate an error condition (invalid code or parameter) or to end the communication. See the I2C Interface section for details of the I2C protocol including acknowledge. The function commands are as follows: 1) Device Reset 5) 1-Wire Single Bit 2) Set Read Pointer 6) 1-Wire Write Byte 3) Write Configuration 4) 1-Wire Reset 7) 1-Wire Read Byte 8) 1-Wire Triplet Table 1. Valid Pointer Codes REGISTER SELECTION CODE Status Register F0h Read Data Register E1h Configuration Register C3h Device Reset Command Code F0h Command Parameter None Description Performs a global reset of device state machine logic. Terminates any ongoing 1-Wire communication. Typical Use Device initialization after power-up; reinitialization (reset) as desired. Restriction None (can be executed at any time). Error Response None Command Duration Maximum 525ns. Counted from falling SCL edge of the command code acknowledge bit. 1-Wire Activity Ends maximum 262.5ns after the falling SCL edge of the command code acknowledge bit. Read Pointer Position Status Register (for busy polling). Status Bits Affected RST set to 1; 1WB, PPD, SD, SBR, TSB, DIR set to 0. Configuration Bits Affected 1WS, APU, SPU set to 0. Set Read Pointer Command Code E1h Command Parameter Pointer Code (see Table 1) Description Sets the read pointer to the specified register. Overwrites the read pointer position of any 1-Wire communication command in progress. Typical Use To prepare reading the result from a 1-Wire Read Byte command; random read access of registers. Restriction None (can be executed at any time). Error Response If the pointer code is not valid, the pointer code is not acknowledged and the command is ignored. Command Duration None. The read pointer is updated on the rising SCL edge of the pointer code acknowledge bit. 1-Wire Activity Not affected. Read Pointer Position As specified by the pointer code. Status Bits Affected None Configuration Bits Affected None www.maximintegrated.com Maxim Integrated | 9 Single-Channel 1-Wire Master DS2482-100 Write Configuration Command Code D2h Command Parameter Configuration Byte Description Writes a new configuration byte. The new settings take effect immediately. Note: When writing to the Configuration Register, the new data is accepted only if the upper nibble (bits 7 to 4) is the one's complement of the lower nibble (bits 3 to 0). When read, the upper nibble is always 0h. Typical Use Defining the features for subsequent 1-Wire communication. Restriction 1-Wire activity must have ended before the DS2482-100 can process this command. Error Response Command code and parameter are not acknowledged if 1WB = 1 at the time the command code is received and the command is ignored. Command Duration None. The Configuration Register is updated on the rising SCL edge of the configuration-byte acknowledge bit. 1-Wire Activity None Read Pointer Position Configuration Register (to verify write). Status Bits Affected RST set to 0. Configuration Bits Affected 1WS, SPU, APU updated. 1-Wire Reset Command Code B4h Command Parameter None Description Generates a 1-Wire reset/presence-detect cycle (Figure 4) at the 1-Wire line. The state of the 1-Wire line is sampled at t SI and tMSP and the result is reported to the host processor through the Status Register, bits PPD and SD. Typical Use To initiate or end any 1-Wire communication sequence. Restriction 1-Wire activity must have ended before the DS2482-100 can process this command. Strong pullup (see the SPU bit) should not be used in conjunction with the 1-Wire Reset command. If SPU is enabled, the PPD bit may not be valid and may cause a violation of the device's absolute maximum rating. Error Response Command code is not acknowledged if 1WB = 1 at the time the command code is received and the command is ignored. Command Duration tRSTL + tRSTH + maximum 262.5ns, counted from the falling SCL edge of the command code acknowledge bit. 1-Wire Activity Begins maximum 262.5ns after the falling SCL edge of the command code acknowledge bit. Read Pointer Position Status Register (for busy polling). Status Bits Affected 1WB (set to 1 for tRSTL + tRSTH), PPD is updated at tRSTL + tMSP, SD is updated at tRSTL + t SI . Configuration Bits Affected 1WS, APU, SPU apply. www.maximintegrated.com Maxim Integrated | 10 Single-Channel 1-Wire Master DS2482-100 1-Wire Single Bit Command Code 87h Command Parameter Bit Byte Description Generates a single 1-Wire time slot with a bit value "V" as specified by the bit byte at the 1-Wire line (see Table 2). A V value of 0b generates a write-zero time slot (Figure 5); a V value of 1b generates a write-one time slot, which also functions as a read-data time slot (Figure 6). In either case, the logic level at the 1-Wire line is tested at tMSR and SBR is updated. Typical Use To perform single-bit writes or reads at the 1-Wire line when single bit communication is necessary (the exception). Restriction 1-Wire activity must have ended before the DS2482-100 can process this command. Error Response Command code and bit byte are not acknowledged if 1WB = 1 at the time the command code is received and the command is ignored. Command Duration t SLOT + maximum 262.5ns, counted from the falling SCL edge of the first bit (MSB) of the bit byte. 1-Wire Activity Begins maximum 262.5ns after the falling SCL edge of the MSB of the bit byte. Read Pointer Position Status Register (for busy polling and data reading). Status Bits Affected 1WB (set to 1 for t SLOT), SBR is updated at tMSR , DIR (may change its state). 1WS, APU, SPU apply. Configuration Bits Affected Table 2. Bit Allocation in the Bit Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 V x x x x x x x x = Don't care. RESET PULSE PRESENCE/SHORT DETECT tMSP tSI VCC PRESENCE PULSE APU CONTROLLED EDGE VIH1 VIL1 RESISTIVE PULLUP 0V tF1 tRSTL PULLUP tRSTH DS2482-100 PULLDOWN 1-Wire SLAVE PULLDOWN Figure 4. 1-Wire Reset/Presence-Detect Cycle www.maximintegrated.com Maxim Integrated | 11 Single-Channel 1-Wire Master DS2482-100 tWOL tMSR VCC VIH1 VIL1 0V tF1 tREC0 tSLOT PULLUP (SEE FIGURE 2) DS2482-100 PULLDOWN Figure 5. Write-Zero Time Slot tMSR tW1L VCC VIH1 VIL1 0V tF1 tSLOT PULLUP (SEE FIGURE 2) DS2482-100 PULLDOWN 1-Wire SLAVE PULLDOWN NOTE: DEPENDING ON ITS INTERNAL STATE, A 1-Wire SLAVE DEVICE TRANSMITS DATA TO ITS MASTER (e.g. THE DS2482-100). WHEN RESPONDING WITH A 0, A 1-Wire SLAVE STARTS PULLING THE LINE LOW DURING tW1L. ITS INTERNAL TIMING GENERATOR DETERMINES WHEN THIS PULLDOWN ENDS AND THE VOLTAGE STARTS RISING AGAIN. WHEN RESPONDING WITH A 1, A 1-Wire SLAVE DOES NOT HOLD THE LINE LOW AT ALL, AND THE VOLTAGE STARTS RISING AS SOON AS tW1L IS OVER. 1-Wire DEVICE DATA SHEETS USE THE TERM tRL INSTEAD OF tW1L TO DESCRIBE A READ-DATA TIME SLOT. TECHNICALLY, tRL AND tW1L HAVE IDENTICAL SPECIFICATIONS AND CANNOT BE DISTINGUISHED FROM EACH OTHER. Figure 6. Write-One and Read-Data Time Slot www.maximintegrated.com Maxim Integrated | 12 Single-Channel 1-Wire Master DS2482-100 1-Wire Write Byte Command Code A5h Command Parameter Data Byte Description Writes a single data byte to the 1-Wire line. Typical Use To write commands or data to the 1-Wire line. Equivalent to executing eight 1-Wire Single Bit commands, but faster due to less I2C traffic. Restriction 1-Wire activity must have ended before the DS2482-100 can process this command. Error Response Command code and data byte are not acknowledged if 1WB = 1 at the time the command code is received and the command is ignored. Command Duration 8 x t SLOT + maximum 262.5ns, counted from falling edge of the last bit (LSB) of the data byte. 1-Wire Activity Begins maximum 262.5ns after falling SCL edge of the LSB of the data byte (i.e., before the data byte acknowledge). Note: The bit order on the I2C bus and the 1-Wire line is different (1-Wire: LSB first; I2C: MSB first). Therefore, 1-Wire activity cannot begin before the DS2482-100 has received the full data byte. Read Pointer Position Status Register (for busy polling). Status Bits Affected 1WB (set to 1 for 8 x t SLOT). 1WS, SPU, APU apply. Configuration Bits Affected 1-Wire Read Byte Command Code 96h Command Parameter None Description Generates eight read-data time slots on the 1-Wire line and stores result in the Read Data Register. Typical Use To read data from the 1-Wire line. Equivalent to executing eight 1-Wire Single Bit commands with V = 1 (write-one time slot), but faster due to less I2C traffic. Restriction 1-Wire activity must have ended before the DS2482-100 can process this command. Error Response Command code is not acknowledged if 1WB = 1 at the time the command code is received and the command is ignored. Command Duration 8 x t SLOT + maximum 262.5ns, counted from the falling SCL edge of the command code acknowledge bit. 1-Wire Activity Begins maximum 262.5ns after the falling SCL edge of the command code acknowledge bit. Read Pointer Position Status Register (for busy polling). Note: To read the data byte received from the 1-Wire line, issue the Set Read Pointer command and select the Read Data Register. Then access the DS2482-100 in read mode. Status Bits Affected 1WB (set to 1 for 8 x t SLOT). Configuration Bits Affected 1WS, APU apply. www.maximintegrated.com Maxim Integrated | 13 Single-Channel 1-Wire Master DS2482-100 1-Wire Triplet Command Code 78h Command Parameter Direction Byte Description Generates three time slots: two read time slots and one write time slot at the 1-Wire line. The type of write time slot depends on the result of the read time slots and the direction byte. The direction byte determines the type of write time slot if both read time slots are 0 (a typical case). In this case, the DS2482-100 generates a write-one time slot if V = 1 and a write-zero time slot if V = 0. See Table 3. If the read time slots are 0 and 1, they are followed by a write-zero time slot. If the read time slots are 1 and 0, they are followed by a write-one time slot. If the read time slots are both 1 (error case), the subsequent write time slot is a write-one. Typical Use To perform a 1-Wire Search ROM sequence; a full sequence requires this command to be executed 64 times to identify and address one device. Restriction 1-Wire activity must have ended before the DS2482-100 can process this command. Error Response Command code and direction byte is not acknowledged if 1WB = 1 at the time the command code is received and the command is ignored. Command Duration 3 x t SLOT + maximum 262.5ns, counted from the falling SCL edge of the first bit (MSB) of the direction byte. 1-Wire Activity Begins maximum 262.5ns after the falling SCL edge of the MSB of the direction byte. Read Pointer Position Status Register (for busy polling). Status Bits Affected 1WB (set to 1 for 3 x t SLOT), SBR is updated at the first tMSR, TSB and DIR are updated at the second tMSR (i.e., at t SLOT + tMSR). Configuration Bits Affected 1WS, APU apply. Table 3. Bit Allocation in the Direction Byte BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 V x x x x x x x x = Don't care. www.maximintegrated.com Maxim Integrated | 14 Single-Channel 1-Wire Master DS2482-100 MSB FIRST MSB LSB MSB LSB SDA SLAVE ADDRESS SCL 1-7 IDLE START CONDITION R/W 8 ACK 9 DATA 1-7 ACK 8 DATA 9 ACK/ NACK 1-7 8 9 REPEATED IF MORE BYTES ARE TRANSFERRED STOP CONDITION REPEATED START Figure 7. I2C Protocol Overview I2C Interface General Characteristics The I2C bus uses a data line (SDA) plus a clock signal (SCL) for communication. Both SDA and SCL are bidirectional lines, connected to a positive supply voltage through a pullup resistor. When there is no communication, both lines are high. The output stages of devices connected to the bus must have an open drain or open collector to perform the wired-AND function. Data on the I 2 C bus can be transferred at rates of up to 100kbps in standard mode and up to 400kbps in fast mode. The DS2482-100 works in both modes. A device that sends data on the bus is defined as a transmitter, and a device receiving data is defined as a receiver. The device that controls the communication is called a master. The devices that are controlled by the master are slaves. To be individually accessed, each device must have a slave address that does not conflict with other devices on the bus. Data transfers can be initiated only when the bus is not busy. The master generates the serial clock (SCL), controls the bus access, generates the START and STOP conditions, and determines the number of data bytes transferred between START and STOP (Figure 7). Data is transferred in bytes with the most significant bit being www.maximintegrated.com transmitted first. After each byte follows an acknowledge bit to allow synchronization between master and slave. Slave Address The slave address to which the DS2482-100 responds is shown in Figure 8. The logic state at the address pins AD0 and AD1 determines the value of the address bits A0 and A1. The address pins allow the device to respond to one of four possible slave addresses. The slave address is part of the slave address/control byte. The last bit of the slave address/control byte (R/W) defines the data direction. When set to 0, subsequent data flows from master to slave (write access); when set to 1, data flows from slave to master (read access). 7-BIT SLAVE ADDRESS A6 A5 A4 A3 A2 A1 A0 0 0 1 1 0 AD1 AD0 MSB AD1, AD0 PIN STATES R/W DETERMINES READ OR WRITE Figure 8. DS2482-100 Slave Address Maxim Integrated | 15 Single-Channel 1-Wire Master DS2482-100 SDA tBUF tF tSP tHD:STA tLOW SCL tHIGH tHD:STA tHD:DAT STOP tSU:STA tR SPIKE SUPPRESSION tSU:STO tSU:DAT START REPEATED START NOTE: TIMING IS REFERENCED TO VIL(MAX) AND VIH(MIN). Figure 9. I2C Timing Diagram I2C Definitions The following terminology is commonly used to describe I2C data transfers. The timing references are defined in Figure 9. Bus Idle or Not Busy: Both SDA and SCL are inactive and in their logic-high states. START Condition: To initiate communication with a slave, the master must generate a START condition. A START condition is defined as a change in state of SDA from high to low while SCL remains high. STOP Condition: To end communication with a slave, the master must generate a STOP condition. A STOP condition is defined as a change in state of SDA from low to high while SCL remains high. Repeated START Condition: Repeated STARTs are commonly used for read accesses to select a specific data source or address to read from. The master can use a repeated START condition at the end of a data transfer to immediately initiate a new data transfer following the current one. A repeated START condition is generated the same way as a normal START condition, but without leaving the bus idle after a STOP condition. Data Valid: With the exception of the START and STOP condition, transitions of SDA can occur only during the low state of SCL. The data on SDA must remain valid and unchanged during the entire high pulse of SCL plus the required setup and hold time (tHD:DAT after the falling edge of SCL and tSU:DAT www.maximintegrated.com before the rising edge of SCL; see Figure 9). There is one clock pulse per bit of data. Data is shifted into the receiving device during the rising edge of SCL. When finished with writing, the master must release the SDA line for a sufficient amount of setup time (minimum tSU:DAT + tR in Figure 9) before the next rising edge of SCL to start reading. The slave shifts out each data bit on SDA at the falling edge of the previous SCL pulse and the data bit is valid at the rising edge of the current SCL pulse. The master generates all SCL clock pulses, including those needed to read from a slave. Acknowledge: Typically a receiving device, when addressed, is obliged to generate an acknowledge after the receipt of each byte. The master must generate a clock pulse that is associated with this acknowledge bit. A device that acknowledges must pull SDA low during the acknowledge clock pulse in such a way that SDA is stable low during the high period of the acknowledge-related clock pulse plus the required setup and hold time (tHD:DAT after the falling edge of SCL and tSU:DAT before the rising edge of SCL). Not Acknowledged by Slave: A slave device may be unable to receive or transmit data, for example, because it is busy performing some real-time function. In this case, the slave device does not acknowledge its slave address and leaves the SDA line high. A slave device that is ready to communicate acknowledges at least its slave address. However, Maxim Integrated | 16 Single-Channel 1-Wire Master DS2482-100 some time later the slave may refuse to accept data, possibly because of an invalid command code or parameter. In this case, the slave device does not acknowledge any of the bytes that it refuses and leaves SDA high. In either case, after a slave has failed to acknowledge, the master first should generate a repeated START condition or a STOP condition followed by a START condition to begin a new data transfer. Not Acknowledged by Master: At some time when receiving data, the master must signal an end of data to the slave device. To achieve this, the master does not acknowledge the last byte that it has received from the slave. In response, the slave releases SDA, allowing the master to generate the STOP condition. Writing to the DS2482-100 To write to the DS2482-100, the master must access the device in write mode, i.e., the slave address must be sent with the direction bit set to 0. The next byte to be sent is a command code, which, depending on the command, may be followed by a command parameter. The DS2482-100 acknowledges valid command codes and expected/valid command parameters. Additional bytes or invalid command parameters are never acknowledged. Reading from the DS2482-100 To read from the DS2482-100, the master must access the device in read mode, i.e., the slave address must be sent with the direction bit set to 1. The read pointer determines the register that the master reads from. The master can continue reading the same register over and over again, without having to readdress the device, e.g., to watch the 1WB changing from 1 to 0. To read from a different register, the master must issue the Set Read Pointer command and then access the DS2482100 again in read mode. www.maximintegrated.com I2C Communication Example See Tables 4 and 5 for the I2C communication legend and data direction codes. Table 4. I2C Communication--Legend SYMBOL S DESCRIPTION START Condition AD, 0 Select DS2482-100 for Write Access AD, 1 Select DS2482-100 for Read Access Sr Repeated START Condition P STOP Condition A Acknowledged A\ (Idle) DRST SRP WCFG Not Acknowledged Bus Not Busy Transfer of One Byte Command "Device Reset", F0h Command "Set Read Pointer", E1h Command "Write Configuration", D2h 1WRS Command "1-Wire Reset", B4h 1WSB Command "1-Wire Single Bit", 87h 1WWB Command "1-Wire Write Byte", A5h 1WRB Command "1-Wire Read Byte", 96h 1WT Command "1-Wire Triplet", 78h Table 5. Data Direction Codes Master-to-Slave Slave-to-Master Maxim Integrated | 17 Single-Channel 1-Wire Master DS2482-100 I2C Communication Examples (continued) Device Reset (After Power-Up) S AD,0 A DRST A Sr AD,1 A A\ P Activities that are underlined denote an optional read access to verify the success of the command. Set Read Pointer (To Read from Another Register) Case A: Valid Read Pointer Code S AD,0 A SRP A C3h A P C3h is the valid read pointer code for the Configuration Register. Case B: Invalid Read Pointer Code S AD,0 A SRP A E5h A\ P E5h is an invalid read pointer code. Write Configuration (Before Starting 1-Wire Activity) Case A: 1-Wire Idle (1WB = 0) S AD,0 A WCFG A A Sr AD,1 A A\ P Activities that are underlined denote an optional read access to verify the success of the command. Case B: 1-Wire Busy (1WB = 1) S AD,0 A WCFG A\ P The master should stop and restart as soon as the DS2482-100 does not acknowledge the command code. 1-Wire Reset (To Begin or End 1-Wire Communication) Case A: 1-Wire Idle (1WB = 0), No Busy Polling to Read the Result S AD,0 A 1WRS A P (Idle) S AD,1 A A\ P In the first cycle, the master sends the command. Then the master waits (Idle) for the 1-Wire reset to complete. In the second cycle, the DS2482-100 is accessed to read the result of the 1-Wire reset from the Status Register. Case B: 1-Wire Idle (1WB = 0), Busy Polling Until the 1-Wire Command is Completed, then Read the Result S AD,0 A 1WRS A Sr AD,1 A A A\ P REPEAT UNTIL THE 1WB BIT HAS CHANGED TO 0. Case C: 1-Wire Busy (1WB = 1) S AD,0 A 1WRS A\ P The master should stop and restart as soon as the DS2482-100 does not acknowledge the command code. www.maximintegrated.com Maxim Integrated | 18 Single-Channel 1-Wire Master DS2482-100 I2C Communication Examples (continued) 1-Wire Single Bit (To Generate a Single Time Slot on the 1-Wire Line) Case A: 1-Wire Idle (1WB = 0), No Busy Polling S AD,0 A 1WSB A A P (Idle) S AD,1 A A\ P The idle time is needed for the 1-Wire function to complete. Then access the device in read mode to get the result from the 1-Wire Single Bit command. Case B: 1-Wire Idle (1WB = 0), Busy Polling Until the 1-Wire Command is Completed S AD,0 A 1WSB A A Sr REPEAT UNTIL THE 1WB BIT HAS CHANGED TO 0. AD,1 A A A\ P When 1WB has changed from 1 to 0, the Status Register holds the valid result of the 1-Wire Single Bit command. Case C: 1-Wire Busy (1WB = 1) S AD,0 A 1WSB A\ P The master should stop and restart as soon as the DS2482-100 does not acknowledge the command code. 1-Wire Write Byte (To Send a Command Code to the 1-Wire Line) Case A: 1-Wire Idle (1WB = 0), No Busy Polling S AD,0 A 1WWB A 33h A P (Idle) 33h is the valid 1-Wire ROM function command for Read ROM. The idle time is needed for the 1-Wire function to complete. There is no data read back from the 1-Wire line with this command. Case B: 1-Wire Idle (1WB = 0), Busy Polling Until the 1-Wire Command is Completed. S AD,0 A 1WWB A 33h A Sr REPEAT UNTIL THE 1WB BIT HAS CHANGED TO 0. AD,1 A A A\ P When 1WB has changed from 1 to 0, the 1-Wire Write Byte command is completed. Case C: 1-Wire Busy (1WB = 1) S AD,0 A 1WWB A\ P The master should stop and restart as soon as the DS2482-100 does not acknowledge the command code. www.maximintegrated.com Maxim Integrated | 19 Single-Channel 1-Wire Master DS2482-100 I2C Communication Examples (continued) 1-Wire Read Byte (To Read a Byte from the 1-Wire Line) Case A: 1-Wire Idle (1WB = 0), No Busy Polling, Set Read Pointer After Idle Time S AD,0 A 1WRB A P (Idle) S AD,0 A SRP A E1h A Sr AD,1 A A\ P The idle time is needed for the 1-Wire function to complete. Then set the read pointer to the Read Data Register (code E1h) and access the device again to read the data byte that was obtained from the 1-Wire line. Case B: 1-Wire Idle (1WB = 0), No Busy Polling, Set Read Pointer Before Idle Time S AD,0 A 1WRB A Sr AD,0 A SRP A E1h A (Idle) S AD,1 A A\ P P The read pointer is set to the Read Data Register (code E1h) while the 1-Wire Read Byte command is still in progress. Then, after the 1-Wire function is completed, the device is accessed to read the data byte that was obtained from the 1-Wire line. Case C: 1-Wire Idle (1WB = 0), Busy Polling Until the 1-Wire Command is Completed S AD,0 A Sr 1WRB AD,0 A A REPEAT UNTIL THE 1WB BIT HAS CHANGED TO 0. Sr AD,1 A A A\ SRP A E1h A Sr AD,1 A A\ P Poll the Status Register until the 1WB bit has changed from 1 to 0. Then set the read pointer to the Read Data Register (code E1h) and access the device again to read the data byte that was obtained from the 1-Wire line. Case D: 1-Wire Busy (1WB = 1) S AD,0 A 1WRB A\ P The master should stop and restart as soon as the DS2482-100 does not acknowledge the command code. www.maximintegrated.com Maxim Integrated | 20 Single-Channel 1-Wire Master DS2482-100 I2C Communication Examples (continued) 1-Wire Triplet (To Perform a Search ROM Function on the 1-Wire Line) Case A: 1-Wire Idle (1WB = 0), No Busy Polling S AD,0 A 1WT A A P (Idle) S AD,1 A A\ P The idle time is needed for the 1-Wire function to complete. Then access the device in read mode to get the result from the 1-Wire Triplet command. Case B: 1-Wire Idle (1WB = 0), Busy Polling Until the 1-Wire Command is Completed S AD,0 A 1WT A A Sr REPEAT UNTIL THE 1WB BIT HAS CHANGED TO 0. AD,1 A A A\ P When 1WB has changed from 1 to 0, the Status Register holds the valid result of the 1-Wire Triplet command. Case C: 1-Wire Busy (1WB = 1) S AD,0 A 1WT A\ P The master should stop and restart as soon as the DS2482-100 does not acknowledge the command code. Applications Information SDA and SCL Pullup Resistors SDA is an open-drain output on the DS2482-100 that requires a pullup resistor to realize high-logic levels. Because the DS2482-100 uses SCL only as input (no clock stretching), the master can drive SCL either through an open-drain/-collector output with a pullup resistor or a push-pull output. Pullup Resistor RP Sizing According to the I2C specification, a slave device must be able to sink at least 3mA at a VOL of 0.4V. This DC condition determines the minimum value of the pullup resistor as: RP(MIN) = (VCC - 0.4V)/3mA With an operating voltage of 5.5V, the minimum value for the pullup resistor is 1.7k. The "MINIMUM RP" line in Figure 11 shows how the minimum pullup resistor changes with the operating voltage. For I2C systems, the rise time and fall time are measured from 30% to 70% of the pullup voltage. The maximum bus capacitance, CB, is 400pF. The maximum rise www.maximintegrated.com time must not exceed 1000ns at standard speed and 300ns at fast speed. Assuming maximum rise time, the maximum resistor value at any given capacitance CB is calculated as: RPMAXS = 1000ns/[CB x ln(7/3)] (standard speed) RPMAXF = 300ns/[CB x ln(7/3)] (fast speed) For a bus capacitance of 400pF, the maximum pullup resistor values are 2.95k at standard speed and 885 at fast speed. A value between 1.7k and 2.95k meets all requirements at standard speed. Because an 885 pullup resistor, as would be required to meet the rise time specification at fast speed and 400pF bus capacitance, is lower than RP(MIN) at 5.5V, a different approach is necessary. The "MAX LOAD AT MIN RP FAST MODE" line in Figure 11 is generated by first calculating the minimum pullup resistor at any given operating voltage ("MINIMUM RP" line) and then calculating the respective bus capacitance that yields a 300ns rise time. Only for pullup voltages of 3V and lower can the maximum permissible bus capacitance of 400pF be maintained. A Maxim Integrated | 21 Single-Channel 1-Wire Master DS2482-100 reduced bus capacitance of 300pF is acceptable for pullup voltages of 4V and lower. For fast speed operation at any pullup voltage, the bus capacitance must not exceed 200pF. The corresponding pullup resistor value at the voltage is indicated by the "MINIMUM RP" line. VCC CURRENT-LIMITING RESISTOR REFER TO APPLICATION NOTE 4206 RP* SDA SCL (I2C PORT) C PCTLZ DS2482-100 AD0 AD1 1-Wire LINE IO 1-Wire DEVICE #1 (WITH SPECIAL POWER REQUIREMENTS) VCC SDA SCL PCTLZ DS2482-100 VCC AD0 AD1 1-Wire LINE IO 1-Wire DEVICE #2 *RP = I2C PULLUP RESISTOR (SEE THE APPLICATIONS INFORMATION SECTION FOR RP SIZING). 2000 500 1600 400 1200 300 MINIMUM RP 800 200 LOAD (pF) MINIMUM RP () Figure 10. Application Schematic MAX LOAD AT MIN RP FAST MODE 400 100 0 0 1 2 3 4 5 PULLUP VOLTAGE (V) Figure 11. I2C Fast Mode Pullup Resistor Selection Chart www.maximintegrated.com Maxim Integrated | 22 Single-Channel 1-Wire Master DS2482-100 Pin Configurations TOP VIEW (BUMP SIDE DOWN) TOP MARK DS2482-100 1 TOP VIEW 2 DS2482-100 3 1 + + A VCC 1 8 AD0 IO 2 7 AD1 GND 3 6 PCTLZ SCL 4 5 SDA 3 A PCTLZ AD1 AD0 2 4 8 2 1 B DS2482-100 2 + B SCL SDA VCC # # # x x C C GND SO (150 mils) y y w w r r IO WLP WLP Ordering Information PART TEMP RANGE PIN-PACKAGE DS2482S-100+ -40C to +85C 8 SO (150 mils) DS2482S-100+T&R -40C to +85C 8 SO (150 mils) DS2482X-100+T -40C to +85C 9 WLP (2.5k pieces) +Denotes a lead(Pb)-free/RoHS-compliant package. T/T&R = Tape and reel. Package Information For the latest package outline information and land patterns (footprints), go to www.maxim-integrated.com/packages. Note that a "+", "#", or "-" in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO. 8 SO (150 mils) S8+4 21-0041 90-0096 9 WLP W92A1+1 21-0067 Refer to Application Note 1891 www.maximintegrated.com Maxim Integrated | 23 Single-Channel 1-Wire Master DS2482-100 Revision History REVISION NUMBER REVISION DATE 1 080604 2 110204 PAGES CHANGED DESCRIPTION Initial release -- I2C trademark note deleted; upper I2C slave address bits changed from 01100b to 00110b. 3 040507 Added the lead(Pb)-free ordering information. 4 091007 Added the UCSP (WLP) package and Package Information section. 5 061208 1, 14 1 1, 21 Updated the Features bullets. 1 Updated the VIL1 and RWPU values in the Electrical Characteristics table. 2 Minor corrections to Figure 1; updated the Detailed Description section to clarify information about the active pullup and strong pullup. 5 Replaced the Strong Pullup (SPU) section description and replaced Figure 4. 7 Removed timing inaccuracies in Figure 8. 14 Created newer template-style data sheet. All Replaced Figure 8. 16 6 7/08 7 8/08 Deleted the 1-Wire line termination resistor and references to it in the Typical Operating Circuit and in Figure 11. 8 11/09 Corrected the recommendation for using active pullup (APU); removed the references to presence-pulse masking. 9 1/12 Updated the soldering information in the Absolute Maximum Ratings section; added a note to the Strong Pullup (SPU) section description; updated the 1-Wire Reset command description (sections Restriction and Configuration Bits Affected); added the land pattern to the Package Information section. 10 1/15 Updated Benefits and Features section 1, 23 1-7, 9-12, 15, 16, 21, 22, 24 2, 7, 10, 23 1 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated's website at www.maximintegrated.com. Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc. (c) 2015 Maxim Integrated Products, Inc. | 24 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Maxim Integrated: DS2482X-100+U