https://www.phoenixcontact.com/us/products/1419645 Flush-type connector-SACC-DSI-M12MS-5CON-M16/0,5-1419645 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Sensor/actuator flush-type plug, 5-pos., M12 SPEEDCON, A-coded, rear/screw mounting with M16 thread, with 0.5 m TPE litz wire, 5 x 0.34 mm Your advantages Pre-assembled with litz wires for immediate use Customer-specific assemblies and litz wire lengths available Sealed on the litz wire side for optimum leak-tightness All standard pin assignments and codings for signal, data, and power transmission with a uniform design-in design For high transmission safety: shield connection to the housing with optional EMC nut SPEEDCON fast locking system reduces cabling times Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356533492 Weight per Piece (excluding packing) 20.000 g Custom tariff number 85444290 Country of origin Germany Technical data Dimensions Length of cable 0.5 m Ambient conditions Ambient temperature (operation) -25 C ... 85 C (Plug / socket) 03/22/2021Page1/8 https://www.phoenixcontact.com/us/products/1419645 Flush-type connector-SACC-DSI-M12MS-5CON-M16/0,5-1419645 Technical data Ambient conditions -25 C ... 85 C (Plug / socket) Degree of protection IP67 (When plugged in) IP65 (When plugged in) General Note The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. Rated current at 40C 4A Rated voltage 60 V Rated surge voltage 1.5 kV Number of positions 5 Insulation resistance 100 M Coding A - standard Standards/regulations M12 connector IEC61076-2-101 Signal type/category Universal Status display No Overvoltage category II Degree of pollution 3 Connection method Individual wires Insertion/withdrawal cycles > 100 Torque 3 Nm ... 4 Nm (Installation-side) Mounting type Rear mounting M16 x 1.5 With flat nut Thread type M16 x 1.5 Material Flammability rating according to UL 94 V0 Contact material CuZn Contact surface material Au Contact carrier material PA 6.6 Material, knurls Zinc die-cast, nickel-plated Sealing material FKM Cable Cable type TPE litz wire Conductor cross section 0.34 mm AWG signal line 22 Conductor structure signal line 7x 0.25 mm 03/22/2021Page2/8 https://www.phoenixcontact.com/us/products/1419645 Flush-type connector-SACC-DSI-M12MS-5CON-M16/0,5-1419645 Technical data Cable Core diameter including insulation 1.2 mm 0.07mm Thickness, insulation 0.21 mm (Core insulation) Wire colors Black, brown,blue, white, gray Material conductor insulation TPE Conductor material Tin-plated Cu litz wires Standards/specifications M12 connector IEC61076-2-101 Insulation resistance 20 M*km Conductor resistance 57.6 m/m Nominal voltage, cable 300 V Test voltage, cable 2000 VAC Ambient temperature (operation) -40 C ... 85 C (cable, fixed installation) -25 C ... 85 C (cable, flexible installation) Standards and Regulations Standards/specifications M12 connector IEC61076-2-101 Flammability rating according to UL 94 V0 Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. * WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. * WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. * The products are suitable for applications in plant, controller, and electrical device engineering. * When operating the connectors in outdoor applications, they must be separately protected against environmental influences. * Assembled products may not be manipulated or improperly opened. * Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products). * When using the product in direct connection with third-party manufacturers, the user is responsible. * For operating voltages > 50V AC, conductive connector housings must be grounded * Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards. * Observe the corresponding technical data. You will find information: o On the product 03/22/2021Page3/8 https://www.phoenixcontact.com/us/products/1419645 Flush-type connector-SACC-DSI-M12MS-5CON-M16/0,5-1419645 Technical data Standards and Regulations o On the packing label o In the supplied documentation o Online at phoenixcontact.com/products under the product * Only use tools recommended by PhoenixContact * Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products * Ensure that the protective or functional ground has been properly connected. * VDE 0100/1.97 411.1.3.2 and DIN EN 60 204/11.98 14.1.3 are applicable when combining several circuits in a cable and/or connector * The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12). Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Schematic diagram 23 3 5 11 10 Pin assignment M12 male connector, 5-pos., Acoded, male side 17 2 18 1 2 M12x1 500 M16x1,5 4 Dimensional drawing 4,5 M12 flush-type plug 03/22/2021Page4/8 https://www.phoenixcontact.com/us/products/1419645 Flush-type connector-SACC-DSI-M12MS-5CON-M16/0,5-1419645 Diagram I [A] Circuit diagram 1 BN 2 WH 4 BK 3 BU 5 GY 9 8 7 6 5 4 3 2 1 0 1 1 0 2 = 5x0,34mm 10 20 30 40 50 60 70 80 90 100 110 120 130 [C] Contact assignment of the M12 plug I = current strength, T = ambient temperature Dimensional drawing Housing cutout for M16 fastening thread, mounting panel with thread Dimensional drawing Housing cutout for M16 fastening thread, mounting panel with feed-through hole (alternatively with area as anti-rotation protection for panel thicknesses > 2 mm up to max. 4.5 mm) Classifications eCl@ss eCl@ss 10.0.1 27440102 eCl@ss 11.0 27440102 eCl@ss 4.0 27140800 eCl@ss 4.1 27140800 eCl@ss 5.0 27143400 03/22/2021Page5/8 https://www.phoenixcontact.com/us/products/1419645 Flush-type connector-SACC-DSI-M12MS-5CON-M16/0,5-1419645 Classifications eCl@ss eCl@ss 5.1 27143400 eCl@ss 6.0 27279200 eCl@ss 7.0 27440103 eCl@ss 9.0 27440102 ETIM ETIM 2.0 EC001297 ETIM 3.0 EC002061 ETIM 4.0 EC002061 ETIM 6.0 EC002061 UNSPSC UNSPSC 6.01 31251501 UNSPSC 7.0901 31251501 UNSPSC 11 31251501 UNSPSC 12.01 31251501 UNSPSC 13.2 39121413 UNSPSC 18.0 39121413 UNSPSC 19.0 39121413 UNSPSC 20.0 39121413 UNSPSC 21.0 39121413 Approvals Approvals Approvals UL Recognized / EAC / cULus Recognized Ex Approvals Approval details 03/22/2021Page6/8 https://www.phoenixcontact.com/us/products/1419645 Flush-type connector-SACC-DSI-M12MS-5CON-M16/0,5-1419645 Approvals UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm Nominal voltage UN 60 V Nominal current IN 4A mm/AWG/kcmil 22 FILE E 118976 EAC B.01687 cULus Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm E221474-20140616 Nominal voltage UN 60 V Nominal current IN 4A mm/AWG/kcmil 22-20 Accessories Accessories Protective cap Sealing cap-PROT-M12 FS-1560251 M12 sealing cap for unoccupied M12 plugs of the sensor/actuator cable, flush-type plugs and I/O devices in the field Sealing cap-PROT-M12 FS-M-1430488 M12 metal sealing cap for unoccupied M12 plugs of the sensor/actuator cable, flush-type plugs and I/O devices in the field 03/22/2021Page7/8 https://www.phoenixcontact.com/us/products/1419645 Flush-type connector-SACC-DSI-M12MS-5CON-M16/0,5-1419645 Accessories Seal Flat gasket-SACC-M16-SEAL CLM-1430394 M16 flat gasket, for rear mounting of M12 flush-type connectors with M16 fastening thread Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 03/22/2021Page8/8