SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load
80ms/230VAC 16ms/115VAC at full load
88 ~ 264VAC 124 ~ 370VDC
47 ~ 63Hz
71% 74%
CH1:28.98 ~ 37.26V
1.6A/115VAC 1A/230VAC
COLD START 20A/115VAC 40A/230VAC
<1mA / 240VAC
105 ~ 150% rated output power
CH1:14.49 ~ 18.63V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
UL60950-1, TUV EN60950-1 approved
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
-10 ~ +60℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
241.3K hrs min. MIL-HDBK-217F (25℃)
159*97*38mm (L*W*H)
0.57Kg; 24pcs/13.7Kg/0.75CUFT
DC ALARM SIGNAL(OPTIONAL)
FUNCTION
Battery low under charge voltage 82.5%±2% CN1 PIN1
Normal 0.8V max. Abnormal 5V±0.5V
AC fail CN1 PIN2
ADD-55A
13.8V
2.5A
0 ~ 3.5A
52.58W
100mVp-p
CH1: 12 ~ 14.5V
±1.0% ±3.0%
±1.0% ±0.5%
±1.0% ±0.5%
5V
CH2
26.5V
CH3
3A 0.16A
0 ~ 4A --------
150mVp-p --------
--------
--------
--------
ADD-55B
27.6V
CH1
1.3A
0 ~ 2A
55.12W
150mVp-p
CH1: 24 ~ 29V
±1.0% ±3.0%
±0.5%
±0.5%
±1.0%
±1.0%
5V
CH2
13.4V
CH3
3A 0.23A
0 ~ 4A --------
100mVp-p --------
--------
--------
--------
55W Dual Output with Battery Charger(USP Function)
‧
‧
‧
‧
‧
‧
‧
■
ADD-55 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 4)
℃
CH1OUTPUT NUMBER
Protection type : AC Charging Mode : Hiccup mode, recovers automatically after fault condition is removed
UPS Mode : Protected by internal fuse
EMC IMMUNITY
EMC EMISSION
File Name:ADD-55-SPEC 2017-07-14