Company background
EnerSys® .................................................................................................................... 3
Services and applications ......................................................................................... 3
Features and benefits ............................................................................................... 5
Technical information
Capacity as a function of temperature ..................................................................... 7
State of charge .......................................................................................................... 7
Storage time as a function of temperature ............................................................... 7
Charging recommendations ...................................................................................... 7
CYCLON® Battery Single Cells
CYCLON® product family .......................................................................................... 8
CYCLON® battery alternate configurations .............................................................. 9
CYCLON® battery standard descriptions ................................................................. 9
CYCLON® battery Single Cell performance specifications .................................... 10
CYCLON® battery Single Cell standard assemblies .............................................. 11
CYCLON® battery BC Single Cell performance specifications .............................. 12
CYCLON® battery Single Cell mechanical specifications ...................................... 13
CYCLON® battery BC Single Cell mechanical specifications ................................ 13
CYCLON® Battery Monobloc
4V/6V Monobloc performance specifications ........................................................ 14
4V/6V Monobloc standard assemblies ................................................................... 15
4V/6V Monobloc mechanical specifications ........................................................... 16
Quick reference list
Standard product listing .......................................................................................... 17
CYCLON
®
BATTERY SELECTION GUIDE
2
Powered by more than 100 years
of expertise, EnerSys® is the
world’s largest industrial battery
manufacturer, operating 21
facilities worldwide. Along with
manufacturing and distributing a
wide range of reserve power and
motive power batteries, chargers,
power equipment, and battery
accessories, EnerSys provides
unmatched aftermarket and
customer support to its customers
in over 100 countries worldwide.
Wherever the world
needs stored energy,
EnerSys® is there.
EnerSys® Value-Added Services
In addition to our manufacturing capability,
EnerSys® is proud to provide its customers with
the following services:
Customised manufacturing design
Battery recycling
Online technical information
Charging support
Product testing
On-site technical seminars
Battery samples
Application engineering
Technical documentation
Charger evaluation to determine
compatibility with CYCLON® batteries
Applications
Batteries from the EnerSys “pure lead” family are
used in a wide variety of standby and portable/
cyclic applications including those in:
Telecommunications
Electronics
Uninterruptible power supplies
Defence installations
Aviation (may require appropriate
agency certification/approval for installation in
aircraft)
Computer back-up
Electric vehicles
Medical equipment
Solar power
Rail
Lawn and garden equipment
Extreme temperature environments
(-65°C to +80°C) for single cells
The EnerSys® plant in Warrensburg, Missouri covers
32,000 square feet and is situated on 33 acres.
3
CYCLON battery Single Cells and Monoblocs
should be handled with care. Batteries are shipped
without individual cell terminal protection and there
is a risk of short circuit if not handled correctly.
4Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
Resealable safety valve
A 50-PSI vent lets gases escape, then automatically reseals, so there’s no
risk of excessive gas accumulation within the battery, or “dry out” failure
from repeated recharges.
Pure lead plates
Made from 99.99% pure lead, CYCLON® battery plates are extremely thin,
so they offer more surface area than conventional batteries –
and far more power.
AGM plate separator
High-purity acid is absorbed right into the Absorbed Glass Mat (AGM)
plate separators, so the CYCLON battery provides leak-proof operation
in any position.
Steel can enclosure
The CYCLON battery’s metal outer jacket offers extreme shock, vibration,
temperature, and flammability protection.
Powerful design
One-piece plastic cover
Direct through-the-wall
intercell connections
One-piece plastic case
Features and Benefits
Sealed pure-lead cells were invented by the Gates Corporation
in 1973. The purity of the materials used is key to supporting
the CYCLON® battery's performance benefits. A longer service
life, meaning fewer replacements and the cost associated with
it, combined with higher reliability and fewer system failures,
result in a lower long-term cost of ownership to the end user
or equipment owner.
What are the advantages of EnerSys® technology?
1. Power density - Per unit weight, the power provided by
pure lead products offers the greatest high-rate power
density for your energy budget. CYCLON® battery's
greater volumetric power allows engineers to consider
more energy-supporting features or design smaller,
lighter packages.
At high-rate and pulse discharges, EnerSys® CYCLON®
batteries offer the best performance value when
compared with competitive product in applications
at less than 100 minutes of discharge.
2. Cycle life - Compared to competitive lead products
(offering up to 200 full cycles), pure lead batteries provide
50% to 200% greater full cycle capability. CYCLON®
batteries will deliver up to 300 cycles (100% DOD, C/5).
And, because CYCLON® batteries incorporate a high
vent-pressure design, EnerSys products experience
no “dry out” failure mode from repeated recharges.
3. Float life - Conventional sealed-lead batteries vary
greatly in specified standby life: from three to six years at
20°C, C/20. CYCLON® battery Single Cells, however, offer a
ten-year design life at 25°C, C/5, to 80% of rated capacity.
At 20°C, CYCLON® battery Single Cells offer a fifteen-year
design life.
4. High stable voltage delivery - The high stable voltage
delivery of a pure lead battery results from its low internal
resistance. The flat discharge voltage profile of our batteries,
similar to nickel cadmium, combined with our products'
low internal resistance, means our batteries are able to
discharge and recharge their power more quickly and
efficiently and offer greater application flexibility. The pure
lead construction also gives more watts-per-unit weight at
high discharge rates.
5. Safety - Since CYCLON® battery Single Cells and
Monoblocs emit minimal to no gassing under normal
charging conditions they are safe for installation in
offices, aircraft cabins, hospitals or any other environment
occupied by human beings. Underwriters Laboratories (UL)
recognises all CYCLON® cells and batteries as components.
6. Widest temperature range - Due to the products' strong
construction and high vent pressures, these cells will
maintain their performance and physical parameters in
extreme conditions. At high temperatures, the chemical
reaction in a battery that causes aging is accelerated.
Pure lead technology resists that chemical reaction more
effectively than alloyed lead, thus allowing a battery to
have a longer service life. At high temperatures, when
conventional lead batteries experience internal moisture
loss from venting and case side wall distention, the
CYCLON® Single Cell battery, with its steel can (jacket)
and 50psi vent, does not experience these life-
robbing conditions. CYCLON® batteries have twice the
delivered capacity of conventional sealed-lead batteries
at temperatures below -20°C, offering unparalleled
low-temperature performance.
Our batteries have thinner plates, and therefore greater
plate surface area than conventional sealed-lead, thick
plate batteries. As a result our batteries can reach a high
state of charge in fast-charging applications in one-fourth
the time of conventional, sealed-lead, thick-plate batteries.
This is 50% to 100% overall better performance for your
energy dollar.
7. Rugged construction - Due to their strong external
packaging and internal pure lead composition, EnerSys®
products can withstand not only extreme temperatures but
also harsh usage.
CYCLON® battery Single Cells are available housed in cases
constructed of UL 94V-0 flame retardant rated material.
The CYCLON® battery Single Cell itself is in a metal jacket
giving added flammability protection. CYCLON® batteries
are shock and vibration resistant, designed to offer higher
tolerance levels to meet demanding applications, including
those in commercial and outdoor applications. The
company's focus on battery-case integrity and high vent
pressure, coupled with pure lead's low grid-corrosion rate,
means CYCLON® battery cells and Monoblocs provide the
longest service life possible.
5
Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
CYCLON® Battery Single Cell/Monobloc comparison chart
Single Cells 3 atm Metal outer case & -65°C to +80°C 2 volt cells
venting pressure spiral construction
Monobloc 0.5 atm Plastic outer case & -40°C to +40°C 4 & 6 volt units
venting pressure spiral construction
Design Construction Operating range Voltages
Each plastic Monobloc consists of Single Cell elements,
internally connected to provide a 4 or 6 volt unit.
Monoblocs or Single Cells can be connected in series
or parallel to achieve the required voltage or capacity.
Monoblocs and Single Cells are supplied with spade
terminals making electrical connections quick and easy.
Additionally, EnerSys® products offer the highest vent
pressure in the market. As a result, our batteries are
more resistant to venting and dryout from continuous
overcharge in standby applications.
8. Fastest recharge - EnerSys® pure lead chemistry
allows our batteries and cells to offer the highest
recharge efficiency of any sealed-lead battery on
the market. With pure lead, you can achieve a 95%
state of recharge in less than one hour - without loss
of capacity or electrolyte using conventional
constant-voltage charging techniques.
Flexible charging options are possible with CYCLON®
battery Single Cells and Monoblocs, as no current limit is
required when using a constant voltage charger.
9. Orientation/placement/transport - Due to the products'
mechanical design, CYCLON® batteries can be mounted
and operated in any position, an attractive feature for less
accessible areas.
CYCLON® battery Single Cells offer UL 94V-0 flame-
retardant packaging, thus allowing the mounting of
systems in sensitive areas and human environments. Plus,
the unique and flexible 2-volt CYCLON® battery Single
Cell allows you to design your system using an almost
infinite number of packaging/design configurations.
CYCLON® single cells and monoblocs are classified
as “non spillable batteries” and are excepted from
comprehensive hazardous packaging requirements.
When shipped from the point of manufacture the product
complies with the relevant requirements of IATA and 49
CFR 173.159(d), specifically CYCLON® product has been
tested and found to comply with IATA Packing instruction
806 and Special Provision A67. As such CYCLON®
product does not have an assigned UN number and is not
required to be shipped under a proper shipping name.
The pure lead advantage
6Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
CYCLON® battery Single Cells and Monoblocs have been
tested and determined to be in compliance with the
vibration and pressure differential tests contained in 49
CFR § 173.159(d).
Because CYCLON® battery Single Cells and Monoblocs
are classified as “Nonspillable” and meet the conditions
above, [from § 173.159(d)] they do not have an assigned
UN number nor do they require additional DOT hazard
labeling.
The regulation change effective September 1995, was to
clarify and distinguish to shippers and transporters, all
batteries that have been tested and determined to be in
compliance with the DOT Hazardous Material Regulations,
the International Civil Aeronautics Organisation (ICAO), and
the International Air Transport Association (IATA) Packaging
Instruction 806 and Special Provision A67, and therefore
excepted from all other requirements of these regulations
and classified as a “nonspillable battery”.
10. Shelf life - Pure lead batteries have an extremely low
self-discharge rate, thus providing extended storage
capability while maintaining high state-of-charge levels for
dependable operation.
CYCLON® battery Single Cells and Monoblocs have a shelf
life more than two times that of conventional lead batteries.
To assure maximum reliability, EnerSys recommends that
all stored cells/batteries be recharged (boost charged) once
every 24 months or when the open circuit voltage drops
to 2.00 volts per cell, whichever occurs earlier. Inventory
should be checked more frequently if storage temperature
regularly exceeds 25°C.
When shipping CYCLON® product, all cells must be
protected against short circuit and the outer packaging
should be plainly and durably marked as “Non Spillable
or Non Spillable Battery”. This applies when product is
repackaged at other locations. It is recommended that
short circuit protection is continued to be applied when
storing and handling CYCLON® product.
Capacity as a function of temperature for CYCLON® Battery Single Cells &
Monoblocs (use graph up to 40°C for Monoblocs)
State of charge for CYCLON® Battery Single Cells & Monoblocs
Figure 5-2: CYCLON® Battery Storage Time Vs. Temperature
Charging recommendations:
Broadly speaking, a battery may be
recharged using either a constant voltage
(CV) charger or a constant current (CC)
charger, or a modification of either or
both of these.
The exact regime chosen generally
depends upon the time and economic
constraints imposed by the system.
Constant current charging is widely used
in cyclic applications where a recharge
must be accomplished in a relatively
short time period. Constant voltage
charging, where a single voltage level
is applied across the battery terminals,
is the most suitable method to recharge
CYCLON® batteries. Depending on the
CV charger's current limit, it is possible
to recharge these batteries from a 100%
discharged condition to better than 95%
state of charge in less than one hour,
using only the cyclic charge voltage.
Constant voltage charging
Constant voltage (CV) charging
should be within the following ranges:
Fast Chargers, Per cell:
2.40 to 2.45 volts @ 25°C
12 volts:
14.40 to 14.70 volts @ 25°C
(for a maximum of 16-20 hours)
In cyclic applications, where the battery
is being significantly discharged at a
frequency greater than once per week,
the charge voltage should be a nominal
value of 2.40 Volts per cell (VPC), but can
range between 2.35 VPC and 2.45 VPC
to maximise cycle life.
Float Chargers, Per cell:
2.27 to 2.35 volts @ 25°C
12 volts:
13.62 to 14.10 volts @ 25°C
Nominal float voltage is 2.27 VPC
at 25°C, but float voltage can range
between 2.25 VPC (@25°C) and 2.35
VPC (@25°C) depending on the details
of the application. Voltages nearer 2.35
VPC would be used in applications
which are float in nature, but could have
frequent discharges of significant Depth
of Discharge (DOD).
To avoid thermal runaway in warmer
temperatures, and to improve charge
acceptance in colder temperatures, the
charger voltage should be compensated
by approximately 3 millivolts per cell per
degree Centigrade variance from 25°C.
This is a negative coefficient, with the
voltage being lowered as the temperature
increases, and vice versa.
7
Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
There is no need to limit the inrush current to the battery
during constant voltage charging. The low internal resistance
of EnerSys® CYCLON® battery Single Cells and Monoblocs
allows for large inrush current without damage.
Since not all of the charge returned is accepted to replenish
the electro-chemical potential, a good rule of thumb to use
is that the charge returned should be 105% to 110% of the
capacity delivered on the previous discharge.
Most current waveforms are not pure DC nor are they pure
sine waves. Therefore, consult the EnerSys® Application
Support Department for assistance when evaluating the
charger current waveforms for your specific application.
A three-step 6-8 hour charge profile optimised for CYCLON®
cells and batteries is available on request from the Technical
Support Department of EnerSys®.
8Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
Internal res. Nominal
of fully charged short circuit
Products Capacity Part Monobloc current for Length Width Height Weight Tabs
Number mΩ @ 25°C charged cell mm mm mm g mm
D cell 2.5Ah 0810-0004 5.0 400A 34.3 61.2 68.1 178.0 4.75x0.64
DT cell 4.5Ah 0860-0004 5.0 400A 34.3 96.0 102.9 274.4 4.75x0.64
X cell 5.0Ah 0800-0004 3.5 570A 2.87 3.21 12.77 362.0 6.35x0.64
E cell 8.0Ah 0850-0004 3.0 665A 44.5 100.1 108.7 489.9 6.35x0.64
J cell 12.0Ah 0840-0004 2.5 800A 51.8 123.2 135.6 839.2 92x0.81
BC cell 25Ah 0820-0004 1.5 1335A 65.3 158.8 173.2 1669.2 M6 (-) and
M8 (+) terminals
DIMENSIONS
Internal res. Nominal
of fully charged short circuit
Products Capacity Part Monobloc current for Length Width Height Weight Tabs
Number mΩ @ 25°C charged cell mm mm mm kg mm
D cell 2.5Ah 0819-0010 10.0 400A 79.5 46.0 69.9 .80 4.75x0.64
X cell 5.0Ah 0809-0010 7.0 570A 96.5 53.8 76.7 1.62 6.35x0.64
E cell 8.0Ah 0859-0010 6.0 665A 96.8 54.1 101.6 2.11 6.35x0.64
DIMENSIONS
CYCLON® Battery Product Family (All capacities at 10 hr. rate 25°C to 1.67Vpc)
CYCLON® Battery 2V Single Cell:
CYCLON® Battery 4V Monoblocs:
Internal res. Nominal
of fully charged short circuit
Products Capacity Part Monobloc current for Length Width Height Weight Tabs
Number mΩ @ 25°C charged cell mm mm mm kg mm
D cell 2.5Ah 0819-0012 15.0 400A 113.8 46.0 69.9 .52 4.75x0.64
X cell 5.0Ah 0809-0012 10.0 570A 139.2 53.8 76.7 .98 6.35x0.64
E cell 8.0Ah 0859-0012 8.0 665A 139.2 54.1 101.6 1.43 6.35x0.64
DIMENSIONS
CYCLON® Battery 6V Monoblocs:
CYCLON® battery standard descriptions
CYCLON® battery cells are ideal for small ampere-hour
applications up to 25Ah. The sealed-lead construction
uses a starved-electrolyte system and a patented
grid-alloy providing numerous advantages.
Standard batteries are offered based on combinations of
the previously described CYCLON® battery cells and are
available in 6 and 12 volt configurations with capacities
ranging from 2.5Ah to 25Ah.
Battery Packages
Rigid plastic cases or shrink wrap packaging are available.
Rigid Plastic
Cases are available for most designs in either flame-retardant
ABS material, meeting UL 94V-0 flammability rating, or
Styrene (available only in 2X3 D and X battery configurations).
Some cases have mounting holes. Rigid plastic cases
are recommended for applications in which the battery
must withstand vibration, movement or extreme weather
conditions.
Shrink Wrap
Shrink wrap packaging is less expensive and smaller in
size and weight. A plastic extrusion insulates the battery
top and keeps the cells in line. A heavy duty shrink sleeve
holds the cells firmly in place. Shrink wrap packaging is
recommended for applications in which the battery remains
stationary.
Battery Terminations for Single Cell and Monoblocs
Tab/Stud
Tab Adapters (D, DT, X, and E)
Available to convert 4.75mm tabs to 6.35mm tabs, 0.81mm
thick, and vice-versa.
BC Quick Disconnect Terminals
AMP series 250 Faston terminals are available for BC
batteries.
Connection Terminations
A wide variety of terminations are offered. For recommendations
or to specify; contact your EnerSys® Territory Manager or
battery assembler.
Fusible Links
Specify your requirement.
CYCLON® Battery Single Cell
Alternative battery configurations
Standard battery configurations are rectangular in
overall shape. A sample of other possible configurations
are illustrated below. These can be held together with
tape (offering the lowest cost and minimum electrical
and mechanical protection) or by shrink wrapping. The
CYCLON® battery Single Cell can be custom configured
in virtually an infinite number of designs.
Rectangular Rhomboid
Nested Trapezoid
Tubular Flat Pack
D 4.75mm x 0.64mm
DT 4.75mm x 0.64mm
X 6.35mm x 0.64mm
E 6.35mm x 0.64mm
J 7.92mm x 0.81mm
BC 6mm post (negative)
8mm post (positive)
Cell size Dimensions
9
Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
Lead Wires
Stranded copper wire with insulation meeting UL1015
specifications (Red +, Black -). Standard leads extend 9
inches outside the battery pack. Ends are stripped and
dipped in wax, which must be removed before use.
Standard wire gauges are:
D batteries 18AWG, UL1015
DT batteries 16AWG, UL1015
X batteries 16AWG, UL1015
E batteries 14AWG, UL1015
J batteries 14AWG, UL1015
BC batteries 12AWG, UL1015
Varying lead lengths and gauges are also available;
please specify to your EnerSys® Territory Manager or
battery assembler.
Intercell Connections
Standard
D, DT, X and E batteries—welded tin-plated steel
connector
J batteries—soldered, stranded wire
BC batteries—solid copper
For vibration-prone applications
D, DT, X, E and J batteries—soldered, stranded wire
BC batteries—braided copper straps
Products 5 min 10 min 15 min 30 min 60 min 90 min 5 hr 8 hr 10 hr 20 hr
D cell (2.5Ah) 14.8 8.1 5.9 3.4 1.9 1.4 .48 .32 .26 .13
DT cell (4.5Ah) 25.2 15.0 11.2 6.6 3.7 2.6 .85 .55 .45 .24
X cell (5.0Ah) 27.3 17.8 13.2 7.0 3.9 2.8 .96 .61 .50 .26
E cell (8.0Ah) 41.7 26.4 19.0 11.0 6.2 4.4 1.6 1.0 .81 .42
J cell (12.0Ah) 51.7 38.1 29.4 18.0 9.2 6.5 2.3 1.5 1.20 .66
DURATION
Constant current discharge/amps to 1.67Vpc @ 25°C
Products 5 min 10 min 15 min 30 min 60 min 90 min 5 hr 8 hr 10 hr 20 hr
D cell (2.5Ah) 26.4 16.1 11.6 6.7 3.8 2.7 .94 .61 .50 .25
DT cell (4.5Ah) 45.0 28.1 21.0 12.5 7.1 5.1 1.7 1.1 .90 .46
X cell (5.0Ah) 45.4 31.9 23.9 13.9 7.8 5.6 1.9 1.2 1.0 .51
E cell (8.0Ah) 77.8 51.0 35.5 21.1 12.4 8.9 3.1 2.0 1.6 .85
J cell (12.0Ah) 90.4 68.4 53.4 31.6 18.3 13.2 4.7 3.0 2.3 1.3
DURATION
Constant power discharge/watts per cell to 1.67Vpc @ 25°C
Products Cyclic Float Storage & Charge C/5 Cycle life Float life at
discharge 100% DOD 25°C (20°C)
D, DT, X, E & J cell CV 2.40 - 2.45 CV 2.27-2.35 -65°C to +80°C -40°C to -80°C 300 10 years
CC* CC* (15 years)
CHARGING PER CELL TEMPERATURE RANGE LIFE EXPECTANCY
Charging/Temperature/Life:
Maximum recommended storage time before recharge - 24 months @ 25°C or 2.0Vpc, whichever is earlier
Atmospheric pressure range - Vacuum to 8 atmospheres
*Users planning to use CC should consult the EnerSys® Application Support Department.
UL Recognised Component. Meets UL 1989
Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container
Sealed-lead rechargeable battery must be recycled or disposed of properly. Contact your local EnerSys® Customer Service Department for details.
CYCLON® Battery Single Cell performance specifications
10 Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
UL - Underwriters Laboratories
AWG - American Wire Gauge
CYCLON® Battery Single Cell standard assemblies
CYCLON® Battery 6 Volt 1x3 Shrink Wrap
CYCLON® Battery 6 Volt 1x3 ABS Case
CYCLON® Battery 12 Volt 2x3 ABS and Styrene Cases
CYCLON® Battery 12 Volt 2x3 Shrink Wrap
CYCLON® Battery 12 Volt 1x6 ABS Case
0810-0102 2.5Ah D Dbl. Slot 102.9 37.6 67.6 .56 No
0810-0103 2.5Ah D 102.9 37.6 67.6 .57 Yes
0860-0102 4.5Ah DT Dbl. Slot 102.9 37.6 102.4 .94 No
0860-0103 4.5Ah DT 102.9 37.6 102.4 .95 Yes
0800-0102 5.0Ah X Dbl. Slot 133.4 47.5 79.2 1.13 No
0800-0103 5.0Ah X 133.4 47.5 79.2 1.14 Yes
0850-0102 8.0Ah E Dbl. Slot 133.4 47.5 106.4 1.58 No
0850-0103 8.0Ah E 133.4 47.5 106.4 1.60 Yes
0810-0011 2.5Ah D Dbl. Slot 107.4 39.4 69.9 .60 No
0810-0077 2.5Ah D Sing. Slot 107.4 39.4 69.9 .62 Yes
0800-0011 5.0Ah X Dbl. Slot 138.2 49.8 80.3 1.23 No
0800-0071 5.0Ah X Sing. Slot 138.2 49.8 80.3 1.24 Yes
0810-0008 2.5Ah D Dbl. Slot 107.4 73.2 69.1 1.22 No
0810-0067* 2.5Ah D (Styrene) 107.4 75.4 69.3 1.19 Yes
0800-0008 5.0Ah X Dbl. Slot 138.2 94.0 79.8 2.42 No
0800-0047* 5.0Ah X (Styrene) 138.2 94.0 81.0 2.37 Yes
0810-0114 2.5Ah D Dbl. Slot 102.9 71.6 67.8 1.13 No
0810-0115 2.5Ah D 102.9 71.6 67.8 1.14 Yes
0860-0114 4.5Ah DT Dbl. Slot 102.9 71.6 102.4 1.76 No
0860-0115 4.5Ah DT 102.9 71.6 102.4 1.77 Yes
0800-0114 5.0Ah X Dbl. Slot 133.4 93.5 79.5 2.24 No
0800-0115 5.0Ah X 133.4 93.5 79.5 2.26 Yes
0850-0114 8.0Ah E Dbl. Slot 133.4 93.5 106.4 3.05 No
0850-0115 8.0Ah E 133.4 93.5 106.4 3.07 Yes
0810-0016 2.5Ah D Dbl. Slot 209.6 39.4 69.6 1.24 No
0810-0075 2.5Ah D Sing. Slot 209.6 39.4 69.6 1.25 Yes
0800-0016 5.0Ah X Dbl. Slot 270.8 49.8 80.0 2.36 No
0800-0072 5.0Ah X Sing. Slot 270.8 49.8 80.0 2.38 Yes
0810-0108 2.5Ah D Dbl. Slot 205.2 37.6 67.6 1.13 No
0810-0109 2.5Ah D 205.2 37.6 67.6 1.14 Yes
0860-0108 4.5Ah DT Dbl. Slot 205.2 37.6 102.4 1.76 No
0860-0109 4.5Ah DT 205.2 37.6 102.4 1.77 Yes
0800-0108 5.0Ah X Dbl. Slot 266.2 47.5 79.2 2.27 No
0800-0109 5.0Ah X 266.2 47.5 79.2 2.28 Yes
0850-0108 8.0Ah E Dbl. Slot 266.2 47.5 106.4 3.05 No
0850-0109 8.0Ah E 266.2 47.5 106.4 3.07 Yes
CYCLON® Battery 12 Volt 1x6 Shrink Wrap
Product Length Width Height Weight Leads
Number Description mm mm mm kg
Product Length Width Height Weight Leads
Number Description mm mm mm kg
Product Length Width Height Weight Leads
Number Description mm mm mm kg
Product Length Width Height Weight Leads
Number Description mm mm mm kg
Product Length Width Height Weight Leads
Number Description mm mm mm kg
Product Length Width Height Weight Leads
Number Description mm mm mm kg
All dimensions, excluding weight, are maximum
*Due to special assembly, consult your local EnerSys® Customer Service Department for availability.
11
Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
Products 5 min 10 min 15 min 30 min 60 min 90 min 5 hr 8 hr 10 hr 20 hr
BC cell (2.5Ah) 118.3 72.8 54.3 32.2 19.3 14.0 4.85 3.14 2.55 1.33
DURATION
Constant current discharge/amps to 1.67Vpc @ 25°C
Products 5 min 10 min 15 min 30 min 60 min 90 min 5 hr 8 hr 10 hr 20 hr
BC cell (2.5Ah) 197.3 142.4 105.5 63.5 36.8 25.6 9.20 6.04 4.95 2.60
DURATION
Constant current discharge/watts per cell to 1.67Vpc @ 25°C
Products Cyclic Float Storage & Charge C/5 Cycle life Float life at
discharge 100% DOD 25°C (20°C)
BC cell (2.5Ah) CV 2.40 - 2.45 CV 2.27-2.35 -65°C to +80°C -40°C to +80°C 300 10 years
CC* CC* (15 years)
CHARGING PER CELL TEMPERATURE RANGE LIFE EXPECTANCY
Charging/Temperature/Life:
Maximum recommended storage time before recharge - 24 months @ 25°C or 2.0Vpc, whichever is earlier
Atmospheric pressure range - Vacuum to 8 atmospheres
Mounting - Terminal torque must not exceed 3.95 Nm
*Users planning to use CC should consult the EnerSys® Application Support Department
UL Recognised Component. Meets UL 1989
Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container
Sealed-lead rechargeable battery must be recycled or disposed of properly. Contact your local EnerSys® Customer Service Department for details.
CYCLON® Battery 12 Volt 2x3 25.0Ah Case
0820-2018
BC Double Slot, 204.5 138.4 184.2 10.4 Yes
Copper Straps
0820-0020 BC Double Slot, 204.5 138.4 184.2 10.4 No
Copper Straps
Product Length Width Height Weight Leads
Number Description mm mm mm kg
All dimensions, excluding weight, are maximum
CYCLON® Battery BC Single Cell performance specifications
12 Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
Products A B C D E F G H I J Weight
mm mm mm mm mm mm mm mm mm gm
D cell 6.9 13.0 4.75 22° 6.9 0.64 61.2 1.3 3.3 34.3 178.0
DT cell 6.9 13.0 4.75 22° 6.9 0.64 96.0 1.3 3.3 34.3 274.4
X cell 7.4 15.5 6.35 22° 8.6 0.64 72.9 1.5 3.6 44.5 362.0
E cell 7.4 15.5 6.35 22° 8.6 0.64 100.1 1.5 3.6 44.5 489.9
J cell 8.1 18.8 7.92 22° 12.4 0.81 123.2 1.3 3.8 51.8 839.2
DIMENSIONS
CYCLON® Battery Single Cell mechanical specifications (E, G, H & J - Maximum)
Products A B C D E F G H I Weight
mm mm mm mm mm mm mm mm kg
BC cell 16.5 33.0 22 14.5 5.6 158.8 1.5 3.3 65.3 1.67
DIMENSIONS
CYCLON® Battery BC Single Cell mechanical specifications (F, G & I - Maximum)
13
Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
For CYCLON® Battery Single Cell constant current (CC) discharge and constant power (CP) discharge information, please refer to the CYCLON® Application Manual -
Appendix A, Figure A-1 and Figure A-2, respectively.
Products 5 min 10 min 15 min 30 min 60 min 90 min 5 hr 8 hr 10 hr 20 hr
D cell (2.5Ah) 14.3 8.1 5.9 3.4 1.9 1.4 .48 .32 .26 .13
X cell (5.0Ah) 28.9 18.1 13.5 7.1 4.0 2.8 1.0 .61 .52 .26
E cell (8.0Ah) 41.7 26.4 19.0 11.0 6.2 4.4 1.6 1.0 .81 .42
DURATION
4V & 6V Constant current discharge/amps to 1.67Vpc @ 25°C
Products 5 min 10 min 15 min 30 min 60 min 90 min 5 hr 8 hr 10 hr 20 hr
D cell (2.5Ah) 25.3 15.9 11.7 6.8 3.8 2.7 .93 .60 .49 .25
X cell (5.0Ah) 48.8 32.3 24.2 13.8 7.8 5.6 2.0 1.2 1.0 .52
E cell (8.0Ah) 77.8 51.0 35.5 21.1 12.4 8.9 3.1 2.0 1.7 .85
DURATION
4V & 6V Constant power discharge/watts per cell to 1.67Vpc @ 25°C
Products Cyclic Float Storage, discharge Safety C/5 Cycle life Float life at
& charge pressure 100% DOD 25°C (20°C)
relief valve
4V D, X, & E CV 4.80 - 4.90 CV 4.54-4.70 -40°C to +40°C 8 psi 300 Up to 8 yrs
Monobloc CC* CC* (Up to 8 yrs)
6V D, X, & E CV 7.20 - 7.35 CV 6.81-7.05 -40°C to +40°C 8 psi 300 Up to 8 yrs
Monobloc CC* CC* (Up to 8 yrs)
CHARGING PER CELL TEMPERATURE RANGE LIFE EXPECTANCY
Maximum recommended storage time before recharge - 24 months @ 25°C or 2.0Vpc, whichever is earlier
Atmospheric pressure range - Vacuum to 2 atmospheres
Mounting - Each Monobloc is equipped with mounting holes in the cover. The tightening torque for mounting the Monobloc is 2.83 Nm. When using 4 mounting bolts, small spacers
(washers) 1 to 3 mm thick should be placed between the battery and the mounting surface to prevent bowing or stressing the battery case.
*Users planning to use CC should consult the EnerSys® Application Support Department.
UL Recognised Component. Meets UL 1989
Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container Sealed-lead rechargeable battery must be recycled or
disposed of properly. Contact your local EnerSys® Customer Service Department for details.”
Charging/Temperature/Life
CYCLON® Battery 4V/6V Monobloc performance specifications
14 Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
15
Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
CYCLON® Battery 4V/6V Monobloc standard assemblies
CYCLON® Battery 4 Volt Monoblocs
0819-0010 4V, 2.5Ah Monobloc 79.5 46.0 69.9 .36
0809-0010 4V, 5.0Ah Monobloc 96.5 53.8 76.7 .74
0859-0010 4V, 8.0Ah Monobloc 96.8 54.1 101.6 .96
Product Length Width Height Weight
Number Description mm mm mm kg
CYCLON® Battery 6 Volt Monoblocs
0819-0012 6V, 2.5Ah Monobloc 113.8 46.0 69.9 .52
0809-0012 6V, 5.0Ah Monobloc 139.2 53.8 76.7 .98
0859-0012 6V, 8.0Ah Monobloc 139.2 54.1 101.6 1.43
Product Length Width Height Weight
Number Description mm mm mm kg
CYCLON® Battery 12 Volt 2x3 Monoblocs
0819-0020 12V, 2.5Ah, 2x3 113.8 89.4 70.4 1.04
0809-0020 12V, 5.0Ah, 2x3 139.2 106.2 77.2 1.96
0859-0020 12V, 8.0Ah, 2x3 139.2 106.2 102.1 2.86
Product Length Width Height Weight
Number Description mm mm mm kg
CYCLON® Battery 12 Volt 1x6 Monoblocs
0819-0016 12V, 2.5Ah, 1x6 224.5 46.0 70.4 1.04
0809-0016 12V, 5.0Ah, 1x6 276.4 53.8 77.2 1.96
0859-0016 12V, 8.0Ah, 1x6 276.4 54.1 102.1 2.86
Product Length Width Height Weight
Number Description mm mm mm kg
All dimensions, excluding weight, are maximums
D Monobloc 69.9 79.5 46.0 15.5 31.2 .36 4.75x0.64
X Monobloc 76.7 96.5 53.8 18.5 36.8 .74 6.35x0.64
E Monobloc 101.6 96.8 54.1 18.5 36.8 .96 6.35x0.64
DIMENSIONS
CYCLON® Battery 4V Monobloc mechanical specifications (A, B & C - maximum)
Products A B C D E Weight Tabs
mm mm mm mm mm kg mm
D Monobloc 69.9 113.8 46.0 15.5 31.2 33.8 17.0 .52 .187x.025 4.75x0.64
X Monobloc 76.7 139.2 53.8 18.5 36.8 43.4 21.8 .98 .250x.025 6.35x0.64
E Monobloc 101.6 139.2 54.1 18.5 36.8 43.4 21.8 1.43 .25x.025 6.35x0.64
DIMENSIONS
CYCLON® Battery 6V Monobloc mechanical specifications (A, B & C - maximum)
Products A B C D E F G Weight Tabs
mm mm mm mm mm kg mm kg mm
D Monobloc
X & E Monobloc
16 Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
For CYCLON® Battery 4V/6V Monobloc constant current (CC) discharge and constant power (CP) discharge information, please refer to the CYCLON® Application Manual -
Appendix A, Figure A-3 and Figure A-4, respectively.
17
Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
ENERSYS® STANDARD PRODUCT LIST
SINGLE CELL (sc)
PART PERFORMANCE MECHANICAL
NUMBER DESCRIPTION VOLTAGE 10 Hr RATE SPECIFICATIONS SPECIFICATIONS
0810-0004 D Single Cell (Dsc) 2V 2.5Ah Page 10 Page 13
0860-0004 DT Single Cell (DTsc) 2V 4.5Ah Page 10 Page 13
0800-0004 X Single Cell (Xsc) 2V 5.0Ah Page 10 Page 13
0850-0004 E Single Cell (Esc) 2V 8.0Ah Page 10 Page 13
0840-0004 J Single Cell (Jsc) 2V 12.0Ah Page 10 Page 13
0820-0004 BC Single Cell (BCsc) 2V 25.0Ah Page 12 Page 13
SINGLE CELL STANDARD BATTERY DESIGNS
PART PERFORMANCE MECHANICAL
NUMBER DESCRIPTION VOLTAGE 10 Hr RATE SPECIFICATIONS SPECIFICATIONS
0810-0102 1x3 Dsc, double slot, shrink wrap 6V 2.5Ah Page 10 Page 11
0810-0103 1x3 Dsc, shrink wrap, leads 6V 2.5Ah Page 10 Page 11
0810-0011 1x3 Dsc, double slot, ABS case 6V 2.5Ah Page 10 Page 11
0810-0077 1x3 Dsc, single slot, ABS case, leads 6V 2.5Ah Page 10 Page 11
0860-0102 1x3 DTsc, double slot, shrink wrap 6V 4.5Ah Page 10 Page 11
0860-0103 1x3 DTsc, shrink wrap, leads 6V 4.5Ah Page 10 Page 11
0800-0102 1x3 Xsc, double slot, shrink wrap 6V 5.0Ah Page 10 Page 11
0800-0103 1x3 Xsc, shrink wrap, leads 6V 5.0Ah Page 10 Page 11
0800-0011 1x3 Xsc, double slot, ABS case 6V 5.0Ah Page 10 Page 11
0800-0071 1x3 Xsc, single slot, ABS case, leads 6V 5.0Ah Page 10 Page 11
0850-0102 1x3 Esc, double slot, shrink wrap 6V 8.0Ah Page 10 Page 11
0850-0103 1x3 Esc, shrink wrap, leads 6V 8.0Ah Page 10 Page 11
0810-0108 1x6 Dsc, double slot, shrink wrap 12V 2.5Ah Page 10 Page 11
0810-0109 1x6 Dsc, shrink wrap, leads 12V 2.5Ah Page 10 Page 11
0810-0016 1x6 Dsc, double slot, ABS case 12V 2.5Ah Page 10 Page 11
0810-0075 1x6 Dsc, single slot, ABS case, leads 12V 2.5Ah Page 10 Page 11
0810-0114 2x3 Dsc, double slot, shrink wrap 12V 2.5Ah Page 10 Page 11
0810-0115 2x3 Dsc, shrink wrap, leads 12V 2.5Ah Page 10 Page 11
0810-0008 2x3 Dsc, double slot, ABS case 12V 2.5Ah Page 10 Page 11
0810-0067* 2x3 Dsc, Styrene case, leads 12V 2.5Ah Page 10 Page 11
0860-0108 1x6 DTsc, double slot, shrink wrap 12V 4.5Ah Page 10 Page 11
0860-0109 1x6 DTsc, shrink wrap, leads 12V 4.5Ah Page 10 Page 11
0860-0114 2x3 DTsc, double slot, shrink wrap 12V 4.5Ah Page 10 Page 11
0860-0115 2x3 DTsc, shrink wrap, leads 12V 4.5Ah Page 10 Page 11
0800-0108 1x6 Xsc, double slot, shrink wrap 12V 5.0Ah Page 10 Page 11
0800-0109 1x6 Xsc, shrink wrap, leads 12V 5.0Ah Page 10 Page 11
0800-0016 1x6 Xsc, double slot, ABS case 12V 5.0Ah Page 10 Page 11
0800-0072 1x6 Xsc, single slot, ABS case, leads 12V 5.0Ah Page 10 Page 11
0800-0114 2x3 Xsc, double slot, shrink wrap 12V 5.0Ah Page 10 Page 11
0800-0115 2x3 Xsc, shrink wrap, leads 12V 5.0Ah Page 10 Page 11
18 Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
0800-0008 2x3 Xsc, double slot, ABS case 12V 5.0Ah Page 10 Page 11
0800-0047* 2x3 Xsc, Styrene case, leads 12V 5.0Ah Page 10 Page 11
0850-0108 1x6 Esc, double slot, shrink wrap 12V 8.0Ah Page 10 Page 11
0850-0109 1x6 Esc, shrink wrap, leads 12V 8.0Ah Page 10 Page 11
0850-0114 2x3 Esc, double slot, shrink wrap 12V 8.0Ah Page 10 Page 11
0850-0115 2x3 Esc, shrink wrap, leads 12V 8.0Ah Page 10 Page 11
0820-0030 2x3 BCsc, double slot, copper strap 12V 25.0Ah Page 12 Page 12
MONOBLOC (mb)
PART DESCRIPTION VOLTAGE 10 Hr RATE PERFORMANCE MECHANICAL
NUMBER SPECIFICATIONS SPECIFICATIONS
0819-0010 D Monobloc (Dmb) 4V 2.5Ah Page 14 Page 16
0809-0010 X Monobloc (Xmb) 4V 5.0Ah Page 14 Page 16
0859-0010 E Monobloc (Emb) 4V 8.0Ah Page 14 Page 16
0819-0012 D Monobloc (Dmb) 6V 2.5Ah Page 14 Page 16
0809-0012 X Monobloc (Xmb) 6V 5.0Ah Page 14 Page 16
0859-0012 E Monobloc (Emb) 6V 8.0Ah Page 14 Page 16
MONOBLOC STANDARD BATTERY DESIGNS
PART DESCRIPTION VOLTAGE 10 Hr RATE PERFORMANCE MECHANICAL
NUMBER SPECIFICATIONS SPECIFICATIONS
0819-0016 1x6 Dmb 12V 2.5Ah Page 14 Page 15
0819-0030 2x3 Dmb 12V 2.5Ah Page 14 Page 15
0809-0016 1x6 Xmb 12V 5.0Ah Page 14 Page 15
0809-0030 2x3 Xmb 12V 5.0Ah Page 14 Page 15
0859-0016 1x6 Emb 12V 8.0Ah Page 14 Page 15
0859-0030 2x3 Emb 12V 8.0Ah Page 14 Page 15
CAPACITY RATINGS BASED ON END OF DISCHARGE VOLTAGE OF 1.67 VOLTS/CELL AT 25°C
*Due to special assembly, consult your local EnerSys® Customer Service Department for availability
PART DESCRIPTION VOLTAGE 10 Hr RATE PERFORMANCE MECHANICAL
NUMBER SPECIFICATIONS SPECIFICATIONS
SINGLE CELL STANDARD BATTERY DESIGNS (continued)
19
Publication No: EN-CYC-SG-004 - June 2014
www.enersys-emea.com
www.enersys-emea.com
Distributed by:
© 2014 EnerSys. All rights reserved.
Trademarks and logos are the property of
EnerSys and its affiliates unless otherwise noted.
Publication No. EN-CYC-SG-004 June 2014 - Subject to revision without prior notice. E.&O.E.
EnerSys
World Headquarters
2366 Bernville Road
Reading, PA 19605
USA
Tel: +1 610 208 1991
+1 800 538 3627
Fax: +1 610 372 8613
EnerSys EMEA
EH Europe GmbH
Löwenstrasse 32
8001 Zürich
Switzerland
EnerSys Asia
152 Beach Road
Gateway East Building
Level 11
189721 Singapore
Tel: +65 6508 1780