© Semiconductor Components Industries, LLC, 2012
August, 2012 Rev. 12
1Publication Order Number:
MKP1V120/D
MKP1V120 Series
Sidac High Voltage
Bidirectional Triggers
Bidirectional devices designed for direct interface with the ac power
line. Upon reaching the breakover voltage in each direction, the device
switches from a blocking state to a low voltage onstate. Conduction
will continue like a Triac until the main terminal current drops below
the holding current. The plastic axial lead package provides high pulse
current capability at low cost. Glass passivation insures reliable
operation.
Features
High Pressure Sodium Vapor Lighting
Strobes and Flashers
Ignitors
High Voltage Regulators
Pulse Generators
Used to Trigger Gates of SCR’s and Triacs
Indicates UL Registered File #E210057
These are PbFree Devices*
MAXIMUM RATINGS (TJ = 25°C unless otherwise noted)
Rating Symbol Value Unit
Peak Repetitive OffState Voltage
(Sine Wave, 50 to 60 Hz, TJ = 40 to 125°C)
MKP1V120, MKP1V130, MKP1V160
MKP1V240
VDRM,
VRRM
"90
"180
V
On-State Current RMS (TL = 80°C,
Lead Length = 3/8, All Conduction Angles)
IT(RMS) "0.9 A
Peak Nonrepetitive Surge Current
(60 Hz One Cycle Sine Wave, TJ = 125°C)
ITSM "4.0 A
Operating Junction Temperature Range TJ40 to +125 °C
Storage Temperature Range Tstg 40 to +150 °C
THERMAL CHARACTERISTICS
Characteristic Symbol Max Unit
Thermal Resistance, JunctiontoLead
Lead Length = 3/8
RqJL 40 °C/W
Lead Solder Temperature
(Lead Length w 1/16 from Case, 10 s Max)
TL260 °C
Stresses exceeding Maximum Ratings may damage the device. Maximum
Ratings are stress ratings only. Functional operation above the Recommended
Operating Conditions is not implied. Extended exposure to stresses above the
Recommended Operating Conditions may affect device reliability.
*For additional information on our PbFree strategy and soldering details, please
download the ON Semiconductor Soldering and Mounting Techniques
Reference Manual, SOLDERRM/D.
SIDACS
0.9 AMPERES RMS
120 240 VOLTS
MT1 MT2
()
http://onsemi.com
AXIAL LEAD
CASE 59
STYLE 2
MARKING DIAGRAM
A = Assembly Location
MKP1Vxx0 = Device Number
x= 12, 13, 16 or 24
YY = Year
WW = Work Week
G=PbFree Package
A
MKP
1Vxx0
YYWW G
G
(Note: Microdot may be in either location)
See detailed ordering and shipping information on page 2 of
this data sheet.
ORDERING INFORMATION
MKP1V120 Series
http://onsemi.com
2
ELECTRICAL CHARACTERISTICS (TC = 25°C unless otherwise noted; Electricals apply in both directions)
Characteristic Symbol Min Typ Max Unit
OFF CHARACTERISTICS
Repetitive Peak OffState Current TJ = 25°C
(50 to 60 Hz Sine Wave)
VDRM = 90 V, MKP1V120, MKP1V130 and MKP1V160
VDRM = 180 V, MKP1V240
IDRM 5.0 mA
ON CHARACTERISTICS
Breakover Voltage
IBO =35 mA MKP1V120
35 mA MKP1V130
200 mA MKP1V160
35 mA MKP1V240
VBO
110
120
150
220
130
140
170
250
V
Peak OnState Voltage
(ITM = 1 A Peak, Pulse Width 300 ms, Duty Cycle 2%)
VTM 1.3 1.5 V
Dynamic Holding Current
(Sine Wave, 50 to 60 Hz, RL = 100 Ohm)
IH 100 mA
Switching Resistance
(Sine Wave, 50 to 60 Hz)
RS0.1 kW
DYNAMIC CHARACTERISTICS
Critical RateofRise of OnState Current,
Critical Damped Waveform Circuit
(IPK = 130 Amps, Pulse Width = 10 msec)
di/dt 120 A/ms
ORDERING INFORMATION
Device Package*Shipping
MKP1V120RLG
DO41, Axial Lead
5000 / Tape & Reel
MKP1V130RLG 5000 / Tape & Reel
MKP1V160G 1000 Units / Bulk
MKP1V160RLG 5000 / Tape & Reel
MKP1V240G 1000 Units / Bulk
MKP1V240RLG 5000 / Tape & Reel
*This package is inherently PbFree.
For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
MKP1V120 Series
http://onsemi.com
3
+ Current
+ Voltage
VTM
IH
Symbol Parameter
IDRM Off State Leakage Current
VDRM Off State Repetitive Blocking Voltage
VBO Breakover Voltage
IBO Breakover Current
IHHolding Current
VTM On State Voltage
ITM Peak on State Current
Voltage Current Characteristic of SIDAC
VDRM
IDRM
ITM Slope = RS
V(BO)
RS+
(V(BO) –V
S)
(IS–I
(BO))
I(BO)
IS
VS
(Bidirectional Device)
0.80
IT(RMS), ON-STATE CURRENT (AMPS)
140
120
40
TA, MAXIMUM AMBIENT TEMPERATURE (°C)
0.4
2.0 3.00
VT, INSTANTANEOUS ON-STATE VOLTAGE (VOLTS)
0.3
0.5
0.2
0.1
1.0
T
4.0
0.2 0.6
I
100
0.7
1.0
130
, MAXIMUM ALLOWABLE LEAD TEMPERATURE ( C)
L
1000
1.0
0.6
0.2
40
I
20 60
0.4
0.8
, ON-STATE CURRENT (AMPS)
T(RMS)
0.2 0.60
IT(RMS), ON-STATE CURRENT (AMPS)
0.50
0.75
0.25
0.4 0.8
P
1.00
1.25
TJ = 25°C
Conduction Angle = 180°C
1.61.2
1.0 1.4 2.01.8
110
90
80
60
70
50
°
80 120 140
5.0
3.0
5.0
2.0
7.0
10
, INSTANTANEOUS ON-STATE CURRENT (AMPS)
T
1.0
, POWER DISSIPATION (WATTS)
RMS
TJ = 25°C125°C
TJ = 125°C
Sine Wave
Conduction Angle = 180°C
Assembled in PCB
Lead Length = 3/8
TJ = 125°C
Sine Wave
Conduction Angle = 180°C
TL
3/83/8
Figure 1. Maximum Lead Temperature Figure 2. Maximum Ambient Temperature
Figure 3. Typical OnState Voltage Figure 4. Typical Power Dissipation
MKP1V120 Series
http://onsemi.com
4
THERMAL CHARACTERISTICS
Figure 5. Thermal Response
t, TIME (ms)
100.1
0.07
0.03
0.02
0.01
5.00.2 0.5 1.0 2.0
0.05
0.1
0.2
r(t), TRANSIENT THERMAL RESISTANCE (NORMALIZED)
0.3
0.5
0.7
1.0
20 50 100 200 500 1.0 k 2.0 k 5.0 k 10 k
The temperature of the lead should be
measured using a thermocouple placed on the
lead as close as possible to the tie point. The
thermal mass connected to the tie point is
normally large enough so that it will not
significantly respond to heat surges generated
in the diode as a result of pulsed operation
once steady-state conditions are achieved.
Using the measured value of TL, the junction
temperature may be determined by:
TJ = TL + DTJL
ZqJL(t) = RqJL r(t)
DTJL = Ppk RqJL[r(t)]
where:
DTJL = the increase in junction temperature above the
lead temperature
r(t) = normalized value of transient thermal resistance at
time, t from this figure. For example,
r(tp) = normalized value of transient resistance at time tp.
TIME
tp
Figure 6. Typical Breakover Voltage Figure 7. Typical Holding Current
Figure 8. Pulse Rating Curve
TJ, JUNCTION TEMPERATURE (°C)
-60
0.8
0.4
1000.1
tw, PULSE WIDTH (ms)
100
10
1.0
I
-40 -20 100 140
0.6
1.0
1.2
10
TJ, JUNCTION TEMPERATURE (°C)
100-60
0.9
0.8
V
40-40 -20 0 20
1.0
1.4
, BREAKOVER VOLTAGE (NORMALIZED)
BO
1.0
IPK, PEAK CURRENT (AMPS)
8060 120 140
, HOLDING CURRENT (NORMALIZED)
H
120
80
0604020
10%
tw
IPK
MKP1V120 Series
http://onsemi.com
5
PACKAGE DIMENSIONS
B
D
K
K
F
F
ADIM MIN MAX MIN MAX
MILLIMETERSINCHES
A4.10 5.200.161 0.205
B2.00 2.700.079 0.106
D0.71 0.860.028 0.034
F−−− 1.27−−− 0.050
K25.40 −−−1.000 −−−
NOTES:
1. DIMENSIONING AND TOLERANCING PER ANSI
Y14.5M, 1982.
2. CONTROLLING DIMENSION: INCH.
3. ALL RULES AND NOTES ASSOCIATED WITH
JEDEC DO41 OUTLINE SHALL APPLY
4. POLARITY DENOTED BY CATHODE BAND.
5. LEAD DIAMETER NOT CONTROLLED WITHIN F
DIMENSION.
AXIAL LEAD
CASE 5910
ISSUE U
STYLE 2:
NO POLARITY
POLARITY INDICATOR
OPTIONAL AS NEEDED
(SEE STYLES)
ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks,
copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/PatentMarking.pdf. SCILLC
reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any
particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without
limitation special, consequential or incidental damages.Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications
and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customers technical experts. SCILLC
does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for
surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where
personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and
its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly,
any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture
of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
N. American Technical Support: 8002829855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81358171050
MKP1V120/D
LITERATURE FULFILLMENT:
Literature Distribution Center for ON Semiconductor
P.O. Box 5163, Denver, Colorado 80217 USA
Phone: 3036752175 or 8003443860 Toll Free USA/Canada
Fax: 3036752176 or 8003443867 Toll Free USA/Canada
Email: orderlit@onsemi.com
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
For additional information, please contact your local
Sales Representative