The FXP7000 Series of rack-mounted power systems provides AC front-end capability to automatic test equipment, telecom, data communications, and other distributed power designs. The hot-pluggable FXP supplies do not include an output isolation diode and may be paralleled up to 210 kW of total output power. These supplies provide excellent protection against input voltage transients. Three-Phase AC Input Suitable for 3U or 5U Height Mounting Single-Wire Current Share or Droop Current Share Remote Voltage Adjust and Current Monitoring Overtemperature, Overload and Overvoltage Protection LED Supply Status Indicators Current Share Control for up to 30 Units Standard & Customized Rack Adaptors Available Front Panel Selectable-Input-Range RoHS Compliant Access to interfaces for remote sensing, remote voltage adjust, current sharing, current monitoring, power supply status, standby voltage and inhibit, as well as power connections, is through a connector at the rear of the supply. The FXP has its fan, handles, voltage adjust, and indicator lights on the front panel and a single hot-plug connector on the rear. Airflow is from the front through the rear. Alarm, monitoring, and control signals are floating from the main output and can be referenced to the positive or negative output or sense line of the power supply. The output is floating with respect to the chassis and may be used as a positive or negative polarity supply. The FXP7000 Series meets international safety requirements and is CE Marked to the Low Voltage Directive. This series operates on three-phase European voltages as well as (up to) 480 VAC, delta or wye. North America +1.866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353.61.225.977 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00275_AB FXP7000 Series MODEL OUTPUT VOLTAGE INPUT VOLTAGE RANGE 3-PHASE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT LINE REGULATION LOAD REGULATION 1 INITIAL SETTING ACCURACY FXP7000-48-SG 48 V 180 to 264 VAC or 342 to 528 VAC 45.6 V to 50.4 V 145 A 0.15% 0.2% 47.90 V to 48.10 V PARAMETER Input Voltage - AC Input Current Inrush Surge Current 2 Input Frequency Hold-up Time Operating Frequency DESCRIPTION/CONDITIONS 3-phase delta low input range, nominal. 3-phase delta high input range, nominal. Continuous deviation from the above nominals. Per phase at full rated load. FXP7000 at 180 VAC: Internally limited. Vin = 264 VAC (one cycle). 25 C: Vin = 528 VAC (one cycle). 25 C: AC input. After last AC line peak at full power. 208 VAC: 400 VAC: Switching frequency, fixed. Power Factor Continuous duty rating. Efficiency Full rated load (208 VAC). Load, Maximum deviation with 0 to 100% load change: With Remote Sense connected: With Remote Sense not connected: Utilizing Droop Current Share: Line, Under all specified operating conditions. Measured at mating connector w/ 0.01F + 10F Tant. 20 MHz BW: 100 MHz BW: Output voltage overshoot/undershoot at turn-on. 88 0 Turn-On Delay Minimum loading required to maintain regulation. Max. recovery time, to within 1% of initial set point due to a 25% load change, 1A/s. Time: Deviation: Time required for initial output voltage stabilization after power-up. Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. Minimum Loads Transient Response 2 UNITS VAC VAC % Arms Apk Hz ms 100 Output Current Overshoot / Undershoot MAX 240 480 +10 30 38 38 63 kHz 0.90 DESCRIPTION/CONDITIONS An additional 1.0 Volt is provided to the output terminals to provide for load lead losses. Continuous duty rating. Ripple & Noise NOM 47 17 13 PARAMETER Output Voltage Adjustment Range Output Power Regulation 1 MIN 200 380 -10 W/VA MIN NOM MAX UNITS 45.6 48 50.4 7000 V Watts 145 A 91 % 0.2 0.75 2.0 0.2 1 2 0 % % p-p % A 800 3.2 3 s % s 100 ms With Remote Sense connected. The minimum time OFF between two turns ON of the unit needs to be > 30 seconds +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00275_AB FXP7000 Series PARAMETER 3, 4 AC Power Fail Warning DESCRIPTION/CONDITIONS MIN NOM MAX UNITS Input Range Select Status Warning provided prior to Vout dropping 5% after loss of AC input. Output voltage - diode isolated. Inclusive of line, load, and initial tolerances. Output current. Monitor output current over a compliance range of 0~10 V. Normal output: Total error current: Static sharing deviation as a percent of full-load rating for loads >10%. Active: Passive: Maximum signal resistance in high input voltage range selection. Loss of Phase Warning Warning provided prior to protective reduction in current limit. Output Inhibit 5 Voltage required to enable supply (0.5 mA sink). 1.0 V Output Interlock 5 Voltage required to enable supply (6 mA sink). 1.0 V Output Overload Protection Straight line current limit (above approx. 5 V Vout). 149 156 A Output Overload Warning 2.2 Output Voltage Fault Signal Signal level on overload. Occurs on overload when Vout is below approx. 5 V. May operate in burst-mode. Deviation from adjusted Vout that is considered as a fault. Output Voltage Margin Overtemperature / Fan Failure Warning Overvoltage Protection Output voltage swing available through Margin pin (analog). Time between fault warning and shutdown. Latching shutdown. Latch style overvoltage protection. Power Supply Present Signal Resistance to logic ground upon insertion of supply. Remote Sense Maximum load lead loss compensation (round trip). PARAMETER ESD Susceptibility DESCRIPTION / CONDITIONS Approved to the latest edition of the following standards: UL/CSA60950-1, IEC60950-1 and EN60950-1. CE marked for the Low Voltage Directive. FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4 Radiated Susceptibility Per EN61000-4-3, level 3. EFT/Burst Per EN61000-4-4, level 4. Per EN61000-4-5. Auxiliary Power Current Monitor Current Share Output Short Circuit Protection Agency Approvals Electromagnetic Interference Input Transient Protection Voltage Sag Immunity Leakage Current Per SEMI F47-0200 FXC/FXP7000 Per UL60950 and EN60950: 4 11.6 0.5 ms 12.0 12.4 V 500 mA 0.5 mA/A mA 0.10 0 5 10 % 0.10 500 Iavg: Line-to-Line: Line-to-Ground: 25 3 ms V 4 90 5 A % 4.8 100 5.0 5.2 % ms 55.2 57.6 60.0 V 1000 1.0 MIN NOM MAX A A 8 V UNITS Class kV 10 V/M 4 4 3 kV kV Pending FXP7000 at 240 VAC, 60 Hz: FXP7000 at 400 VAC, 50 Hz: FXP7000 at 480 VAC, 60 Hz: 5 7 10 mA 3 All logic outputs listed below feature a standard active pull-down output with 0.4V max at 40mA sink capability, and a 100k pull-up to 5V. In addition to those listed below, signals and front-panel LEDs are provided to indicate: overtemperature / fan fault, AC phase imbalance, output good, interlock open, and supply inhibited. The FXP also provides 4 LED's indicating output loading. 5 Both signals must be pulled to logic ground for the unit to operate. Enables are 100% redundant internally for applications where redundant inhibit is desirable. Contact factory for additional design details. 4 +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00275_AB FXP7000 Series PARAMETER Altitude DESCRIPTION/CONDITIONS Operating. Non-Operating. MIN At 100% load: At 50% load: Operating Temperature NOM MAX 10k 40k 40 70 85 0 Storage Temperature -40 UNITS ASL Ft. C C Temperature Coefficient 0C to 70C (after 15-minute warm-up). .02 %/C Relative Humidity Non-Condensing. Operating: half-sine 10 ms, 3 axis Non-operating: half-sine 10 ms, 3 axis Operating: swept sine 5-2000-5 Hz, 5-32 Hz, 0.02iDA, 32-2000 Hz Non-operating: random 10-2000 Hz 95 +20 +40 1 6.15 155 4.4 555 2.8 %RH Shock Vibration Airflow Airflow provided through the supply from front to rear. PARAMETER DESCRIPTION / CONDITIONS MIN Mechanical Dimensions 16.96" x 8.00" x 5.00" (430.8 mm x 203.2 mm x 127.0 mm) Weight 13 kg (29 lb) NOM MAX Gpk Gpk Grms cfm m3/min Ifm m/s UNITS Figure 1 - Rear and Front Views for FX76000 FRONT VIEW 5. 000" (127m m ) REAR VIEW LOCK HA NDLE RE LEA SE INP UT VOLT AGE RANGE S E LE CT MODULE ROTA TE 180 DEGREE S FOR 240 VAC I NPUT VOLTA GE DI SPLAY CUTOUT 2. 437" (61. 90m m ) 0. 521" (13. 24m m ) CE NTE R -TOCE NTE R 0. 090" (2. 29m m ) 2P L 48 0 VAC 4. 552" (115. 62m m ) 3. 901" (99. 09m m ) 0. 222" (5. 64m m ) MATING CONNECTOR INFORMATION Tyco PN Elcon PN Description 1648601-1 296-22-01100 CONN HSING FEM 52P TOP DRAWER 1648420-1 712-12-01107 CONTACT SOCKET #0 DOUBLE CROWN 1648318-1 702-32-01107 CONN SOCKET #12 BLIND MATE 1648325-1 702-92-01109 CONN SOCKET #20 BLIND MATE CL 0. 226" (5. 74m m ) CL +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00275_AB FXP7000 Series Figure 2 - FXC7000 Overall Size 16.09" (408.7mm) 14.259" (362.18mm) 11.704" (297.28mm) 7.509" (190.73mm) MAIN TAIN 25 SQ IN MIN F REE AREA (F RONT AND REAR ) F OR AIR COOLING A A A 4.954" (125.83mm) 0.87" (22.1mm) A LOC K H AND LE L ED H AN D L E <--AIRFLOW 5.750" (146.05mm) 8.00" (203.2mm) SIDE VIEW A A A 1.100" (27.94mm) A 0.341" (8.66mm) 0.649" (16.48mm) 0.590" (14.99mm) LOC K H OOK 0.480" (12.19mm) NOTE: TOTAL BOTTOM STAC KU P OF R AC K MUST BE N O GR EATER TH AN 0.20 4 ". 16.96" (430.8mm) A A 0.204" (5.18mm) A A 4.000" (101.6mm) BOTTOM VIEW A A A A 1.759" (44.68mm) 15.462" (392.73mm) FOR OPTION AL H AR D MOU N TING, U SE M4 X 0.7 SC R EWS, 8 PL (MAR KED A) ON SID E OR BOTTOM WITH MAXIMU M PEN ETR ATION 3.8mm. R EC OMMEN D ED MOU N TING TORQU E 10.5 IN C H L BS. (0.64 N/M) +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00275_AB FXP7000 Series NOTE: FXP7000 POWER SUPPLIES ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY AND ARE NOT INCLUDED AS PART OF POWER SHELF ASSEMBLY. . 19.000" (482.6mm) 18.312" (465.12mm) 0.129" 4PL (3.28mm) 2.250"2PL (57.15mm) 5.215" (132.46mm) 1.484" 2PL (37.69mm) FXP7000 2PL NOTE: The FRH7000G Power Shelf is designed for alternative vertical mounting with the right side down. +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00275_AB FXP7000 Series (Used with FRH7000G Power Shelf) This kit is used to cover an unused right-side slot of the FRH7000G Power Shelf (as viewed from the front of the FRH7000G). The kit can be installed before, or after installation of the power shelf into the rack. BRACKET, 2 PLACES FILLER PANEL (FILLER PANEL KIT AS SEEN FROM INSIDE OF POWER SHELF) +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00275_AB FXP7000 Series NOTE: FXP7000 POWER SUPPLIES ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY AND ARE NOT INCLUDED AS PART OF POWER SHELF ASSEMBLY. 8.70" (221.0mm) 7.184" 2PL (182.47mm) I NPUT VOLTA GE DI SPLAY CUTOUT R 0.129" 4PL (3.28mm) INP UT V OLTAGE RANGE S E LE CTMODULE 1.434" 2PL (36.42mm) 480 VAC 480 VAC 480VAC 0.000 +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00275_AB FXP7000 Series (Used with FRV7000G Power Shelf) This kit is used to cover an unused left or center slot of the FRV7000G Power Shelf (as viewed from the front of the FRV7000G). One kit is required per slot. Kits can be installed before, or after installation of the power shelf into the rack. UPPER BRACKET FILLER PANEL LOWER BRACKET (FILLER PANEL KIT AS SEEN FROM INSIDE OF POWER SHELF) NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00275_AB