FRENCH CYLINDRICAL URB/URD/URL SEMICONDUCTOR PROTECTION FUSES PROTISTOR(R) FUSES 600V AC URD from 0.10 up to 0.80A** 500V AC URB/URD/URL from 1 up to 30A SIZE: 10 X 38 Features / Benefits Extremely high Interrupting rating Fuses: Protection of power Semiconductors according to IEC 269.1 and 4 500-600V AC Voltage Rating aR Class according to VDE 636-23 and IEC 269.4 Without blown fuse indication according to NF C 63210 and 63211 - 0.10 up to 0.80A** With built in Trip-Indicator (1 up to 30A) Ferraz Specialty* APPLICATIONS DATA Voltage rating UN( VAC ) 600 V without blown fuse indication Class URD ** URD 500 V with trip-indicator URB URL Current rating IN (A) 100 mA 125 mA 160 mA 200 mA 250 mA 315 mA 400 mA 500 mA 630 mA 800 mA 1A 1.25 A 1.6 A 2A 2.5 A 3.15 A 4A 5A 6A 8A 10 A 12 A 16 A 20 A 25 A 30 A Pre-arcing I2t @ 1 ms I2tp (A2s) Total clearing I2t @ UN I2tt (A2s) 1.2 10 -3 2.3 10 -3 5.2 10 -3 8 10 -3 18 10 -3 33 10 -3 56 10 -3 0.100 0.18 0.44 1.3 1.7 2.2 3.1 5.9 9 16 36 47 80 110 150 200 290 580 900 0.49 0.13 0.31 0.65 1.65 2.80 5.30 12.7 1.3 2.3 3.6 5.25 9.30 16 37 58 * minimum operating voltage for trip-indicator:20 V ** higher ratings 1 to 30 A see A070 gRB 30 T13 D 90 Watt losses 0.8 IN 0.23 0.25 0.28 0.34 0.35 0.42 0.46 0.46 0.52 0.58 0.4 0.52 0.58 0.63 0.63 0.86 1.1 1.1 0.73 0.83 1 1.3 1.7 1.7 2.9 3.5 IN 0.4 0.44 0.48 0.58 0.60 0.73 0.80 0.80 0.90 1 0.7 0.91 1 1.1 1.1 1.5 1.8 1.8 1.35 1.55 1.9 2.3 3.1 3.2 4.25 5.1 Tested interrupting rating 200 kA @ 600 V 50 kA @ 500 V 50 kA @ 500 V 50 kA @ 500 V FRENCH CYLINDRICAL URB/URD/URL SEMICONDUCTOR PROTECTION FUSES PART NUMBERS 10.3x38 - Without blown fuse indicator CURRENT RATING 38.2 38,2 10,3 10.3 REF # CATALOG NO. 100 mA A 060 URD 0.100 T13 H077632 125 mA A 060 URD 0.125 T13 J077633 160 mA A 060 URD 0.160 T13 K077634 200 mA A 060 URD 0.200 T13 L077635 250 mA A 060 URD 0.250 T13 M077636 315 mA A 060 URD 0.315 T13 N077637 400 mA A 060 URD 0.400 T13 P077638 500 mA A 060 URD 0.500 T13* Q077639 630 mA A 060 URD 0.630 T13* R077640 800 mA A 060 URD 0.800 T13* S077641 * UL Recognized 10.3x38 - With blown fuse trip-indicator CURRENT RATING 38.2 38,2 10,3 10.3 7 2,5 2.5 D 91 CATALOG NO. PART # 1A A 050 URD 001 T13 I P076925 1.25A A 050 URD 001.2 T13 I H076597 1.6A A 050 URD 001.6 T13 I G076596 2A A 050 URD 002 T13 I Q076926 2.5A A 050 URD 002.5 T13 I F076595 3.15A A 050 URD 003 T13 I R076927 4A A 050 URD 004 T13 I S076928 5A A 050 URD 005 T13 I T076929 6A A 050 URB 006 T13 I V076930 8A A 050 URB 008 T13 I W076931 10A A 050 URB 010 T13 I X076932 12A A 050 URB 012 T13 I Y076933 16A A 050 URB 016 T13 I Z076034 20A A 050 URB 020 T13 I A076935 25A A 050 URL 025 T13 I B076936 30A A 050 URL 030 T13 I C076937 D