The FXC7000 Series of standalone or rackmounted power systems provides true AC front-end capability to automatic test equipment, telecom, data communications, and other distributed power designs. The FXC systems may be paralleled up to 210 kW of output power and are intended for chassismounted installations with bolted connections. These power supplies provide excellent protection against input voltage transients. The FXC has its fan located at the front of the supply, and voltage adjust, indicator lights, output busbars, and connectors on the rear. Airflow is from the front through the rear. Alarm, monitoring, and control signals are floating from the main output and can be referenced to the positive or negative output or sense line of the power supply. The output is floating with respect to the chassis and may be used as a positive or negative polarity supply. Three-Phase AC Input Suitable for 3U or 5U Height Mounting Single-Wire Current Share or Droop Current Share Remote Voltage Adjust and Current Monitoring Overtemperature, Overload and Overvoltage Protection LED Supply Status Indicators Current-Share Control for up to 30 Units Front Panel Selectable-Input-Range RoHS Compliant The FXC7000 Series meets international safety requirements and is CE Marked to the Low Voltage Directive. This series operates on three-phase European voltages as well as (up to) 480 VAC, delta or wye. North America +1-866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00371_AB FXC7000 Series MODEL OUTPUT VOLTAGE FXC7000-48-SG2,3 48 V INPUT VOLTAGE RANGE 3-PHASE 180 to 264 VAC or 342 to 528 VAC ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT LINE REGULATION LOAD REGULATION1 INITIAL SETTING ACCURACY 45.6 V to 50.4 V 145 A 0.15% 0.2% 47.90 V to 48.10 V All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER Input Voltage-AC Input Current CONDITIONS / DESCRIPTION MIN 3-phase delta low input range, nominal 200 3-phase delta high input range, nominal Continuous deviation from the above nominals MAX UNITS 240 VAC 380 480 VAC -10 +10 % FXC7000 at 180 VAC 30 Arms Vin = 264 VAC (one cycle). 25C 30 Apk 15 Apk 63 Hz Per phase at full rated load Inrush Surge Current Internally limited Input Frequency AC input Hold-up Time After last AC line peak at full power Operating Frequency Switching frequency, fixed Vin = 528 VAC (one cycle). 25C 47 208 VAC 17 ms 400 VAC 13 ms 100 Power Factor CONDITIONS / DESCRIPTION An additional 1.0 Volt is provided to the output terminals to provide for load lead losses Continuous duty rating Output Current Continuous duty rating Efficiency Overshoot / Undershoot Full rated load (208 VAC) Load, Maximum deviation with 0 to 100% load change: With Remote Sense connected: With Remote Sense not connected: Utilizing Droop Current Share: Line, Under all specified operating conditions. Measured at mating connector w/ 0.01F + 10F Tant 20 MHz BW 100 MHz BW Output voltage overshoot/undershoot at turn-on Minimum Loads Minimum loading required to maintain regulation Transient Response Maximum recovery time, to within 1% of initial set point due to a 25% load change, 1A/S. Turn-On Delay Time required for initial output voltage stabilization after power-up Turn-on Rise Time Time required for output voltage to rise from 10% to 90% Ripple & Noise kHz 0.9 PARAMETER Output Voltage Adjustment Range Output Power Regulation NOM W/VA MIN NOM MAX UNITS 45.6 48 50.4 V 7000 W 145 88 91 A % 0.2 0.75 2.0 0.2 1 2 0 0 % % p-p % A Time 800 s Deviation 3.2 % 3 s 100 ms 1 With Remote Sense connected. User-selectable input voltage ranges 3 Please contact Bel Power Solutions for availability, if non-RoHS version FXC7000-48-S is needed 2 +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00371_AB FXC7000 Series PARAMETER4, 5 CONDITIONS / DESCRIPTION AC Power Fail Warning Warning provided prior to Vout dropping 5% after loss of AC input Output voltage - diode isolated. Inclusive of line, load, and initial tolerances. Output current: Auxiliary Power Current Monitor MIN Monitor output current over a compliance range of 0~10 V. Normal output: Total error current: 11.6 Maximum signal resistance in high input voltage range selection. Loss of Phase Warning Warning provided prior to protective reduction in current limit. UNITS 12.4 V 500 mA 0.5 mA/A mA 5 % 10 % 0.10 Active Input Range Select Status Passive 500 ms 6 Output Inhibit Voltage required to enable supply (0.5 mA sink) Output Interlock Voltage required to enable supply (6 mA sink) 5 Output Overload Protection Straight line current limit (above approx. 5V Vout). 149 Output Overload Warning 2.2 Output Voltage Fault Signal Signal level on overload. Occurs on overload when Vout is below approx. 5V. May operate in burst-mode. Deviation from adjusted Vout that is considered as a fault. Output Voltage Margin Overtemperature/ Fan Failure Warning Overvoltage Protection Output voltage swing available through Margin pin (analog). Time between fault warning and shutdown. Latching shutdown Latch style overvoltage protection Power Supply Present Signal Resistance to logic ground upon insertion of supply. Remote Sense Maximum load lead loss compensation (round trip). Agency Approvals 12.0 0.10 Static sharing deviation as a percent of full-load rating for loads >10%. PARAMETER MAX ms 0.5 Current Share Output Short Circuit Protection NOM 4 Iavg: 1.0 V 1.0 V 156 A V 25 90 A 3 4 5 % 4.8 5.0 5.2 % 100 55.2 ms 57.6 60.0 V 1000 CONDITIONS / DESCRIPTION Approved to the latest edition of the following standards: UL/CSA60950-1, IEC60950-1 and EN60950-1. CE marked for the Low Voltage Directive. FCC CFR title 47 Part 15 Sub-Part B - Conducted MIN NOM 1.0 V MAX UNITS A Class EN55022 / CISPR 22 Conducted A Class ESD Susceptibility Per EN61000-4-2, level 4 8 kV Radiated Susceptibility Per EN61000-4-3, level 3 10 V/M EFT/Burst Per EN61000-4-4, level 4 4 kV Input Transient Protection Per EN61000-4-5 Line-to-Line 4 kV Line-to-Ground 3 kV Voltage Sag Immunity Per SEMI F47-0200 FXC/FXP6000 Electromagnetic Interference Leakage Current Per UL60950 and EN60950 Pending FXC7000 at 240 VAC, 60 Hz FXC7000 at 400 VAC, 50 Hz FXC7000 at 480 VAC, 60 Hz 5 7 10 mA mA mA 4 All logic outputs listed below feature a standard active pull-down output with 0.4V max at 40 mA sink capability, and a 100k pull-up to 5V. In addition to those listed below, signals and front-panel LEDs are provided to indicate: overtemperature / fan fault, AC phase imbalance, output good, interlock open, and supply inhibited. The FXC also provides 4 LED's indicating output loading. 6 Both signals must be pulled to logic ground for the unit to operate. Enables are 100% redundant internally for applications where redundant inhibit is desirable. Contact factory for additional design details. 5 +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00371_AB FXC7000 Series PARAMETER CONDITIONS / DESCRIPTION MIN NOM Operating Altitude Non-Operating At 100% load: Operating Temperature 0 At 50% load: Storage Temperature -40 MAX UNITS 10k ASL Ft. 40k ASL Ft. 40 C 70 C 85 C Temperature Coefficient 0C to 70C (after 15-minute warm-up) .02 %/C Relative Humidity Non-Condensing 95 %RH Shock Operating: half-sine 10 ms, 3 axis +20 Non-operating: half-sine 10 ms, 3 axis +40 Operating: swept sine 5-2000-5 Hz, 5-32 Hz, 0.02iDA, 32-2000 Hz Vibration Non-operating: random 10-2000 Hz Airflow Airflow provided through the supply from front to rear. PARAMETER CONDITIONS / DESCRIPTION MIN Mechanical Size 15.17" x 8.00" x 5.00" (385.3 mm x 203.2 mm x 127.0 mm) Weight 27 lb (12 kg) Gpk 1 Gpk 6.15 Grms 155 cfm 4.4 m3/min 555 lfm 2.8 m/s NOM MAX UNITS Figure 1 - Rear and Front Views for FXC7000 FRONT VIEW REAR VIEW 9 18 26 5.00" (127mm) 1 10 19 AC INPUT PE L1 L2 0.06 (1.7) 2 PL M4 THREAD 13mm CENTER-TO-CENTER DC OUTPUT L3 PO S 10mm 8.00" (203.2mm) N EG VOLTAGE ADJUST POT 5 LED INDICATORS 26-PIN CONNECTOR AMP PN: 749030-1 PIN 1 SIGNAL AC DC T Vadj MATING CONNECTOR: CONNECTOR SHELL... AMP PN 748365-1 CONTACTS... AMP PN 748333-2 INPUT VOLTAGE RANGE SELECT MODULE ROTATE 180 DEGREES FOR 240 VAC 4 8 0 VAC INPUT VOLTAGE DISPLAY CUTOUT +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00371_AB FXC7000 Series Figure 2 - FXC7000 Overall Size MAINTAIN 25 SQ IN MIN FREE AREA (FRONT AND REAR) FOR AIR COOLING 7.705" (195.7mm) 3.510" (89.2mm) 0.955" (24.3mm) 1.10" (27.9mm) 15.17" (385.3mm) 10.260" (260.6mm) 0.85" (21.6mm) A A A A 6.850" (174mm) 5.42" (137.7mm) INSULATOR BLOCK <--AIRFLOW 4.24" (107.6mm) SIDE VIEW A A A A 1.100" (27.9mm) 0.53" (13.4mm) 2 PL 3.60" 4.480" (91.5mm) (113.8mm) 0.480" (12.2mm) A A A FOR MOUNTING, US E M4 X 0.7 S CRE WS, 8P L (MA RK E D A ) ON S IDE OR B OTTOM WITH MA X IMUM P E NE TRATION 3.8mm. 2 P L 1.22" (31.1mm) DIA 0.25" (6.4mm) RE COMME NDE D MOUNTING TORQUE 10.5 INCH LB S. (0.64N/M) BOTTOM VIEW A 0.955" A (24.3mm) 2 PL A A A 0.70" 2 PL (17.9mm) 1.10" 2 PL (28mm) 0.20" (5.1mm) 3.510" (89.2mm) 7.705" (195.7mm) 13.455" (341.8mm) NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. +1.866.513.2839 tech.support@psbel.com (c) 2015 Bel Power Solutions, Inc. BCD.00371_AB