IDC Sockets for Discrete Wires XG5 1
IDC Sockets for Discrete Wires
XG5
Trouble-free discrete-wire termination with IDC
Sockets that mate with XG4 and XG8 Plugs.
Two-row, IDC construction and insulation barrel offers high
reliability and large-current (3 A) discrete wiring capability.
Adaptable to a variety of covers for space-saving and
discrete wire termination.
By using the simple, unique top lock-lever system, these Con-
nectors can be locked to either the XG8B/XG8W Unshrouded
Plugs (with right-angle terminals) or XG4C Box-type Plugs.
Conforms to UL standards (file no. E 103202). (Except
XG5S models)
RoHS Compliant.
Construction
Cover (Semi-cover or Hood
Cover) Semi-cover shown here.
Socket (with polarizing guide)
Polarizing guide
IDC contacts
Lance
Wire can be connected without
stripping cable insulation.
Two-slot connection
Insulation barrel
Solderless Contact
Ratings and
Characteristics
Note: For standard 0.15-mm gold plating.
Rated current 1 A (AWG28)
2 A (AWG26)
3 A (AWG24)
Rated voltage 300 VAC
Contact resistance 20 mΩmax. (at 20 mV,
100 mA max.)
Insulation
resistance
1,000 MΩmin.
(at 500 VDC)
Dielectric strength 650 VAC for 1 min (leakage
current: 1 mA max.)
Connector insertion 1.96 N max. per contact
Contact removal 0.29 N min. (with test
gauge, 0.64 x 0.64 mm)
Insertion durability
(See note.)
50 times
Ambient
temperature
Operating: 55 to 85°C
(with no icing)
C
urrent and Temperature
C
haracteristics
Use the temperature data shown below as a reference for selecting current values and wires.
Rise in temperature (°C)
UL1061 AWG24 (XG5M-2032-N)
UL1007 AWG26 (XG5M-2035-N)
20 wires
20
wires
Temp. rise limit 10 wires
10 wires
2
wires
2 wires
Current flow (A)
Rise in temperature (°C)
Current flow (A)
UL1061 AWG24
UL1007 AWG26
Flow rate = (no. of contacts used) × 100%
(total no. of contacts)
Temp. rise limit
2IDC Sockets for Discrete Wires XG5
Materials and Finish
Note: For non-standard plating, contact your OMRON representative.
Applicable Wires and Contact Sizes
Note: The contact numbers are marked on the contact insulation barrels.
Assembled Configuration
Insulation Displacement (IDC) versus Crimp Termination
IDC termination provides the following advantages over crimp style termination, when using discrete wires;
Overall cost is lower, because less manhours are required. Wire
stripping is eliminated and inspection is easier.
IDC termination provides consistent quality, improving yield.
XG5 terminals are installed in the socket housing at the factory,
simplifying the Bill of Material and parts control.
Optional replacement IDC terminals facilitates re-configuration of wiring.
Assembly
Applicable Mating Plugs
Housing Fiber-glass reinforced PBT resin
(UL94V-0)/black
Contacts Mating end Phosphor-bronze/nickel base,
0.15-μm gold plating (See note.)
Terminals Phosphor-bronze/nickel base,
2.0-μm solder plating
Cover Fiber-glass reinforced polyamide
resin (UL94V-0)/black
Cable tie Polyamide resin (UL94V-0)/natural
Size #1 AWG24 (For UL-1061) Insulation outside diameter:
1.1 to 1.3 mm}
Core structure: 7 strands or
more
Size #2 AWG28 or AWG26 (For
UL-1007)
Socket Wire
Discrete wires
Connections
IDC Tool
Hood Cover
Cover
Semi-cover
Vertical
Horizontal
Assembled unit
Double-row
Assembled
Simple IDC Tool
(See the “XG@ - Assembly Tooling and Accessories”
datasheet for details.)
Double rows
with polarity
guide
(lockable)
Double rows
with polarity
guide
(lockable)
Double rows
with polarity
guide
(lockable)
XG4A
PCB Plugs with Long Locks
XG4A
PCB Plugs w/o Lock Lever
XG4A
PCB Double-row Plugs
(See Note 3)
XG4E
IDC Flat Cable Plugs
XG4C
PCB Box-type Plugs
XG8W/XG8B
Double-row Unshrouded Plugs
Note: 1. See XG4 and XG8 datasheets
for plug dimensions.
2. When using the XG4A or XG4C,
the number of XG4A or XG4C's
polarity slots must be the same
as the number of XG5M-N polar-
ity guides.
3. Mount external Lock Levers after
soldering.
IDC Sockets for Discrete Wires XG5 3
Double-row Sockets
XG5M-N
Dimensions
Ordering Information
Note: 1. The 10-contact XG5M-1031-N and XG5M-1034-N have no polarizing guides.
2. The distance between slots is 22.86 mm for the two guides on 50, 60, and 64-contact Connectors.
3. See the XG4 and XG8 datasheets for Mating Plug information.
4. Applicable discrete wire is AWG24 (UL1061) for size #1.
5. Applicable discrete wire is AWG28 to AWG26 (UL-1007) for size #2.
Size no.
Polarizing guide
Models with no polarizing guide
XG5M-1031-N (size #1)
XG5M-1034-N (size #2)
Models with polarizing guide
XG5M-@@32-N (size #1)
XG5M-@@33-N (size #1)
XG5M-@@35-N (size #2)
XG5M-@@36-N (size #2)
Dimensions
No. of
contacts
Dimensions (mm)
AB
10 17.3 10.16
14 22.3 15.24
16 24.9 17.78
20 30.0 22.86
26 37.6 30.48
30 42.7 35.56
34 47.7 40.64
40 55.4 48.26
50 68.1 60.96
60 80.8 73.66
64 85.8 78.74
Appearance
No. of contacts No. of
polarizing guide
Size #1 Size #2
10 0 XG5M-1031-N XG5M-1034-N
1XG5M-1032-N XG5M-1035-N
14 1 XG5M-1432-N XG5M-1435-N
16 1 XG5M-1632-N XG5M-1635-N
20 1 XG5M-2032-N XG5M-2035-N
26 1 XG5M-2632-N XG5M-2635-N
30 1 XG5M-3032-N XG5M-3035-N
34 1 XG5M-3432-N XG5M-3435-N
40 1 XG5M-4032-N XG5M-4035-N
50 1 XG5M-5032-N XG5M-5035-N
2XG5M-5033-N XG5M-5036-N
60 1 XG5M-6032-N XG5M-6035-N
2XG5M-6033-N XG5M-6036-N
64 1 XG5M-6432-N XG5M-6435-N
2XG5M-6433-N XG5M-6436-N
4IDC Sockets for Discrete Wires XG5
Semi-covers
XG5S
Semi-covers are used to cover the IDC termination area and insulation barrels, after wiring is completed. If the entire socket needs to covered, use
XG5S Hood Covers.
Dimensions
Ordering Information
Note: One Semi-cover is used per termination row. Each XG5M Connector requires two semi-covers. Semi-covers are not packaged in pairs.
Assembled Dimensions (Socket with Semi-cover)
XG5S-@@01
Di
mens
i
ons
No. of
contacts
Dimensions (mm)
A
5 17.3
7 22.3
8 24.9
10 30.0
13 37.6
15 42.7
17 47.7
20 55.4
25 68.1
30 80.8
32 85.8
No. of
contacts
Model Applicable Connector
5XG5S-0501 XG5M103@-N
7XG5S-0701 XG5M-143@-N
8XG5S-0801 XG5M-163@-N
10 XG5S-1001 XG5M-203@-N
13 XG5S-1301 XG5M-263@-N
15 XG5S-1501 XG5M-303@-N
17 XG5S-1701 XG5M-343@-N
20 XG5S-2001 XG5M-403@-N
25 XG5S-2501 XG5M-503@-N
30 XG5S-3001 XG5M-603@-N
32 XG5S-3201 XG5M-643@-N
Dimensions
No. of
contacts
Dimensions (mm)
AB
10 17.3 32.0
14 22.3 37.1
16 24.9 39.6
20 30.0 44.7
26 37.6 52.3
30 42.7 57.4
34 47.7 62.5
40 55.4 70.1
50 68.1 82.8
60 80.8 95.5
64 85.8 100.6
MIL Plug + Semi-cover
O
r
i
g
i
na
lPl
ug +
Semi-cover +
Lock Lever
IDC Sockets for Discrete Wires XG5 5
Hood Covers
XG5S
Dimensions
Ordering Information
Note: Hood Covers are packaged / shipped with left and right halves. Includes cable tie.
Vertical
XG5S-@@12
(Left and right halves)
Dimensions
No. of
contacts
Dimensions (mm)
ABC
20 30.0 23.8 8.8
26 37.6 31.4 11.4
30 42.7 36.5 15.1
Horizontal
XG5S-@@22
(Left and right halves)
Dimensions
No. of
contacts
Dimensions (mm)
ABCD
34 47.7 38.7 32.0 14.6
40 55.4 40.7 34.0 16.6
50 68.1 44.1 39.4 20.0
60 80.8 47.4 42.8 23.4
Appearance Vertical Horizontal
No. of contacts
(double rows)
Model (See note.) Model (See note.)
20 XG5S-2012
26 XG5S-2612
30 XG5S-3012
34 XG5S-3422
40 XG5S-4022
50 XG5S-5022
60 XG5S-6022
6IDC Sockets for Discrete Wires XG5
Assembled Dimensions (Socket and Hood Cover)
Applicable Plugs
XG4A, XG4C, XG4E and XG8 are recommended.
XG4C and XG8 Plugs do not have locks. To prevent accidental
removal, use a Lock Lever (XG4Z-0002, XG5Z-0002). (Lock Levers
cannot be used with XG8W Straight Terminal Connectors.)
When mounting the XG8 Original Plug (with right-angle terminals)
to a circuit board, be sure that the cover is positioned off the board
as shown below.
Vertical Hood Cover
Dimensions
No. of
contacts
Dimensions (mm)
AB
20 30.0 44.7
26 37.6 52.3
30 42.7 57.4
Assembled Unit
Plug + Vertical Hood Cover
Horizontal Hood Cover
Dimensions
No. of
contacts
Dimensions (mm)
ABCDEF
34 47.7 39.0 45.7 62.5 46.4 53.1
40 55.4 41.0 47.7 70.1 48.4 55.1
50 68.1 46.4 51.1 82.8 53.8 58.5
60 80.8 49.8 54.4 95.5 57.2 61.8
Assembled Unit
Plug + Horizontal Hood Cover
Original Plug Cover
Board
XG5
Edge7 mm max.
IDC Sockets for Discrete Wires XG5 7
XG5 Accessories
Top Lock Levers
Spare Contacts
Contact Removal Tool
XY2E-0001
Used to remove contacts, which need to be replaced or reconfigured,
from the housing.
Replacing Contacts
Use only this tool to remove incorrect IDC contacts.
1. Remove the cover.
2. Insert the tool into the housing lance holes and push the lance
into the housing.
3. Pull out the contact while holding the lance down.
4. Insert a new contact.
XG5 IDC Assembly Tools
See the “XG@- Assembly Tooling and Accessories” datasheet for details regarding manual and automated IDC Termination tools (part numbers
XY2B-7006 and XY2B-2104-N)
Material: Polyamide resin
(UL94V-2)/natural
Material: Polyamide resin
(UL94V-2)/natural
XG5Z-0002 - “Lock Lever”
Use to lock unshrouded, double-row, right-angle Plugs (XG8B
and XG8W) to XG5 or XG4 mating sockets.
XG4Z-0002 - “Lock Lever II”
Use to lock XG4C Box-type Plugs.
Mounting the Lock Lever
For Sockets with polarity guides, mount the
Lock Lever to the tab to lock the Socket to the
Unshrouded Plug as shown in the diagram on
the right.
Model
XG5Z-0002
XG4Z-0002
Size no.
XG5W-0031-N (Size #1)
XG5W-0034-N (Size #2)
Note: 1. These Contacts can be used as re-
placements if a wrong connection
is made.
2. The applicable wire for size No. 1 is
AWG24 (UL-1061). The applicable
wire for size No. 2 is AWG26 to
AWG28 (UL-1007).
Model
XG5W-0031-N
XG5W-0034-N
Lance Holding
Par t
XY2E-0001
Lance hole
Housing
8IDC Sockets for Discrete Wires XG5
Precautions
Correct Use
IDC Connectors
For best results, use only the XG5 IDC Tool. (See the “XG@-
Assembly Tooling and Accessories” datasheet.)
Contact your OMRON representative for details on the XG5 IDC Tool.
Check the Contact size (No. 1 or No 2) and wire size before connecting.
OMRON has a IDC Tool Reference Manual. Contact your OMRON
representative to request a copy.
Mounting the Cover
The cover is used to protect the connection position and prevent
shorting out.
Mounting the Semi-cover
See the above diagram.
1. Insert part A of the Semi-cover into part B of the Socket.
2. Push the claws on both sides of the Semi-cover onto the Socket.
3. Make sure the claws are firmly inserted in the slots.
4. To protect the wires, use cable ties to bind wires that may be sub-
ject to tension even when a Semi-cover is used.
Mounting the Hood Cover
Vertical Hood Cover
See the above diagram.
1. Insert the claws of part A of the Hood Cover into the slots.
2. Insert claws B on the Hood cover into part C on the other part of
the Hood Cover.
3. Wrap the wires with a cable tie.
Horizontal Hood Cover
Follow the mounting procedure for the vertical cover.
The left and right parts of the cover are different. Assemble care-
fully.
XG5M-N Double-row Socket Contact Numbers XG4M Terminal Numbers
The Contact numbers on the Double-row Assembled Socket match
the numbers on the XG4M Flat Cable MIL Socket. (See the above
diagrams.)
When making IDC connections on the Double-row Assembled Con-
nector, use the polarity guide to distinguish the front and back.
(Note: The 10-contact Connector does not have a guide.)
Slot
Claw
Semi-cover
Cable tie
Triangular mark Terminal
numbers Polarizing guide
Triangular mark Not marked on connector.
IDC Sockets for Discrete Wires XG5 9
MEMO
10 IDC Sockets for Discrete Wires XG5
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. G042-E-01 Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/14 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.