TYPES YBA-A
BREAK-AWAY™ HYLUG™
Copper and Aluminum
Compression Terminals
UL Listed 90° C,
600 Volts to 35 kV
The Break-Away line of Copper and
Aluminum HYLUG™
terminals are
designed to provide maximum eld exibility
by allowing the installer (using the break-
away feature) to easily convert a two-hole
terminal into a one-hole terminal to suit the
application.
The Break-Away HYLUG™ line of terminals
encompasses a wide range of features that
offers the installer the exibility to meet the
requirements of challenging projects.
BURNDY®
Canada: 1-800-387-6487 www.burndy.com US: 1-800-346-4175
Features & Benets
• Break-Away feature allows for eld
modication of the terminal from a
two-hole design to a one-hole design
while retaining UL Listing and CSA
Certication
• Field modication of the terminal does
not require specialized tooling or
training
• Stud size is 1/2″ on the rst stud as well
as the slotted second stud
• Slotted second stud provides built in
exibility for the terminal to conform to
various bus bar dimensions. With the
slotted second stud the terminal can be
used on two-hole spacing ranging from
1.75″ down to 1.00″ for 1/2″ stud size
• Narrow tongue design allows for the
terminal to t into tight spaces
• Accommodates a wide range of
conductor combinations (AWG,
Compact, DLO, Flex and Metric)
• Break-Away HYLUG™ line of terminals
Catalog
Number
Conductor
Size
(Concentric
and
Compact)
Dimensions Installation Tooling (# of crimps)
Stud
Hole
Spacing
Stud
Hole
Size
Tongue
Width B T L Dieless
MD6, MD7,
MD7-34R
platforms
OUR840**
Y500CTHS,
PAT60018V,
PATMD6
platform
Y35, Y39,
Y750, *Y46,
PAT750,
*PAT46
platforms
Color
Code
Die
Index
YBA25A 1/0
1”
to
1.75”
1/2″
1.03″
1.05″0.17″4.59″MY29 (MY29
platform tools can
only be used on
Code Conductor),
PAT644 & Y644
platforms (1),
4-POINT®
Y81K, PAT81K,
Y4PC, PAT4PC
platforms (2)
W241 (2)
X241 (4) W241 (2) U25ART (1) Tan 296
YBA26A 2/0 1.17″0.20″4.78″— — U26ART (2) Olive 297
YBA27A 3/0 1.04″1.31″0.26″5.02″— — U27ART (2) Ruby 467
YBA28A 4/0 1.17″1.39″0.30″5.19″W660 (4)
X660 (8) W660 (4) U28ART (2) White 298
YBA29A 250 kcmil 1.26″1.45″0.33″5.28″PAT644 & Y644
platforms (1),
4-POINT® Y81K,
PAT81K, Y4PC,
PAT4PC
platforms (2)
— — U29ART (2) Red 324
YBA30A 300 kcmil 1.38″1.53″0.36″5.64″— — U30ART (2) Blue 470
YBA31A 350 kcmil 1.52″1.85″0.39″6.07″PAT644 & Y644
platforms (1),
4-POINT® Y81K,
PAT81K, Y4PC,
PAT4PC
platforms (4)
— — U31ART (2) Brown 299
YBA32A 400 kcmil 1.62″2.26″0.43″6.15″— — U32ART (4) Green 472
YBA34A 500 kcmil 2.34″0.46″6.80″— — U34ART (4) Pink 300
YBA36A 600 kcmil 1.31″2.47″0.52″7.09″— — U36ART (4) Black 473
YBA39A 700 & 750 kcmil 1.62″2.46″0.43″7.07″— — U39ART-2 (2) Yellow 936
YBA42A 900 kcmil AL
600 kcmil CU 1.62″ 2.46″ 0.43″ 7.07″
Y644MBH (2)
Y644HSXT (2)
PAT644XT -18V (2)
— — U42ART (4)
^
Gray 303
YBA44A 1000 kcmil 1.65″2.74″0.55″7.76″Y644MBH (1) — — P44ART† (4) Brown 302
can be installed with standard BURNDY®
tooling such as PAT750XT-18V and
U-Dies
• Terminals are range taking when
installed with Y644 or PAT644 tooling
platforms
† Can only be crimped with PAT46 or Y46 platform tools
using the P44ART die.
* Y46 and PAT46 platforms require PUADP-1 adaptor to
use U dies
** OUR840 can use X-style dies only.
^ U die for 900 AL only
Aluminum Conductor
Compression Connections
AL9CU