DS26008 Rev. 4 - 2
1 of 3
www.diodes.com
PR1001 - PR1005
© Diodes Incorporated
PR1001 - PR1005
1.0A FAST RECOVERY RECTIFIER
Features
• Diffused Junction
• Fast Switching for High Efficiency
• High Current Capability and Low Forward Voltage Drop
• Surge Overload Rating to 30A Peak
• Low Reverse Leakage Current
• Lead Free Finish, RoHS compliant (Note 4)
Mechanical Data
• Case: DO-41
• Case Material: Molded Plastic. UL Flammability Classification
Rating 94V-0
• Moisture Sensitivity: Level 1 per J-STD-020D
• Terminals: Finish - Tin. Plated Leads Solderable per MIL-STD-202,
Method 208
• Polarity: Cathode Band
• Marking: Type Number
• Ordering Information: See Page 3
• Weight: 0.35 grams (approximate)
Dim DO-41 Plastic
Min Max
A 25.40 ⎯
B 4.06 5.21
C 0.71 0.864
D 2.00 2.72
All Dimensions in mm
Maximum Ratings and Electrical Characteristics @TA = 25°C unless otherwise specified
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Characteristic Symbol PR1001 PR1002 PR1003 PR1004 PR1005 Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage (Note 5)
VRRM
VRWM
VR 50 100 200 400 600 V
RMS Reverse Voltage VR(RMS) 35 70 140 280 420 V
Average Rectified Output Current (Note 1) @ TA = 75°C IO 1.0 A
Non-Repetitive Peak Forward Surge Current 8.3ms
Single Half Sine-Wave Superimposed on Rated Load IFSM 30 A
Forward Voltage Drop @ IF = 1.0A VFM 1.2 V
Peak Reverse Current @ TA = 25°C
at Rated DC Blocking Voltage (Note 5) @ TA = 100°C IRM 5.0
100 μA
Reverse Recovery Time (Note 3) trr 150 250 ns
Typical Total Capacitance (Note 2) CT 15 8.0 pF
Typical Thermal Resistance Junction to Ambient RθJA 75 °C/W
Operating and Storage Temperature Range TJ, TSTG -65 to +150 °C
Notes: 1. Valid provided that leads are maintained at ambient temperature at a distance of 9.5mm from the case.
2. Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
3. Measured with IF = 0.5A, IR = 1A, Irr = 0.25A. See figure 5.
4. EU Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied, see EU Directive 2002/95/EC Annex Notes.
5. Short duration pulse test used to minimize self-heating effect.