68
5015 - AMPHENOL AIB/GT SERIES MIL-DTL-5015
For assistance in North America: +1 800.642.8750 for Pricing/Delivery or +1 800.523.0727 Tech Support • www.peigenesis.com • sales@peigenesis.com
SEALING RANGE
16 .064 - .130 1.62 - 3.30
12 .114 - .170 2.89 - 4.31
8 .164 - .255 4.16 - 6.47
4 .272 - .370 6.90 - 9.30
0 .415 - .550 10.50 - 13.97
CONTACT
SIZE
Wire Sealing Range The connector is designed for individual wire sealing. Sealing of an outer
cable jacket on multiconductor cables must be accomplished with an
appropriate endbell. Sealing is only guaranteed if wires used are
according to MIL-W-5086 or within the listed ranges.
INCHES MM
Insulation Strip Lengths See Contact Selection Chart on apages 94 and 97
Mating Life 2,000 cycles minimum (AIB/GT) 500 cycles minimum (AIBC/ACA-B)
Salt Spray Olive drab chromate over cadmium - 500 hours
Black alloy - 48 to 200 hours
Conductive black alloy - 48 to 200 hours
Black anodized - 500+ hours
Electroless nickel - 48 hours
Heat Neoprene low-smoke, zero-halogen (LSZH) 257˚F (+125˚C);
Viton 392˚F (+200˚C)
Chemical Resistance Diesel Fuel 48-hour intermittent spray for each
JP-4 chemical with no deterioration,
Hydraulic Fluid followed by Contact Retention (CR),
Gasoline Insulation Resistance (IR), Dielectric Withstanding
Voltage tests (DWV)
Corrosion Resistance Olive Drab Cadmium-Plated 48 hours per MIL-DTL-5015 (3.17/4.6.13)
Fluid Immersion Hydraulic Fluid 20 hours per MIL-DTL-5015 (3.19/4.6.15)
Lubrication Oil 20 hours per MIL-DTL-5015 (3.19/4.6.15)
Vibration Per MIL-STD-810C, method 516.2, procedure VIII
1.0 g peak from 5 to 25 Hz
.030” double amplitude from 25 to 57 Hz
5g peak from 57 to 500 Hz
Basic Shock Per MIL-STD-810C, method 516.2, procedure I pulse at half-sine
wave of 30g for 11 seconds
Gun fire Shock Per MIL-STD-810C, method 516.2, procedure IV pulse at half-sine
wave of 100g for 1.5 seconds
Ballistic Shock Per MIL-STD-810C, method 516.2, procedure IV pulse at half sine
wave of 200g for .5 seconds
Contact Type Solder, crimp, PC, coax, or thermocouple. Hard silver or gold plating.
Contact Insertion From rear with simple hand-tool. Removable, 5 cycles minimum.
Contact Retention Pin and socket contacts are designed to resist severe vibration and
repeated connection and disconnection. Contact retention and separation
is tested according to MIL-DTL-5015H (4.6.6.1)
CONTACT SIZE RETENTION FORCE MIN.
16 10
12 15
8 20
4 20
0 25
TECHNICAL
SPECIFICATIONS