SunPower Series
HLMP-WLxx HLMP-NL06
HLMP-WHxx HLMP-NH04
HLMP-WGxx HLMP-NG07
Features
• T-1 (3 mm) and T-1 3/4
(5 mm) General Purpose
LED Lamps
• AlInGaP SunPower Intensity
• High Light Output
• Clear and Tinted Diffused
Lens Options
• Narrow and Wide Viewing
Angles
• Amber, Red-Orange, and Red
• Available on Tape and Reel
Description
This family of 3 mm and 5 mm
LED lamps is specially designed
for applications requiring higher
levels of intensity than is
achieved with a standard lamp.
The 5 mm lamp is available with
15, 30, and 65 degree viewing
angle options. The 3 mm lamp is
available with a 60 degree
viewing angle.
Applications
• General Purpose
• Consumer Goods
• Indicator Lights
Device Selection Guides
T-1 3/4 (5 mm) Lamp Package Luminous Intensity Viewing Angle
Color Part Number Diff. Tint Min. mcd, If @ 20 mA 2θ 1/2 (Degrees)
Amber HLMP-WL12 450 15
Amber HLMP-WL27 205 30
Amber HLMP-WL02 X X 35 65
Red Orange HLMP-WH12 270 15
Red Orange HLMP-WH27 155 30
Red Orange HLMP-WH02 X X 35 65
Red HLMP-WG12 270 15
Red HLMP-WG27 155 30
Red HLMP-WG02 X X 26 65
T-1 (3 mm) Lamp Package Luminous Intensity Viewing Angle
Color Part Number Diff. Tint Min. mcd, If @ 20 mA 2θ 1/2 (Degrees)
Amber HLMP-NL06 96.2 60
Red Orange HLMP-NH04 90.2 60
Red HLMP-NG07 90.2 60
High Intensity AlInGaP
LED Lamps
Technical Data
22
Technical Data
Amber Red-Orange Red
(λd = 590 nm)[1] (λd = 615 nm)[1] (λd = 626 nm)[1]
Minimum Minimum Minimum
Typical Luminous Luminous Luminous Package
Viewing Part Intensity Part Intensity Part Intensity Drawing/
Angle, 2θ1/2 No. Iv (mcd)[3,4], No. Iv (mcd)[3,4], No. Iv (mcd)[3,4], Nominal
(Deg.)[2] HLMP- @ 20 mA HLMP- @ 20 mA HLMP- @ 20 mA Epoxy Diameter
15 WL12 450 WH12 270 WG12 270 clear A/5 mm
30 WL27 205 WH27 155 WG27 155 clear A/5 mm
65 WL02 35 WH02 35 WG02 26 tinted A/5 mm
diffused[5]
60 NL06 96.2 NH04 90.2 NG07 90.2 clear B/3 mm
Notes:
1. Dominant Wavelength, λd, is derived from the CIE Chromaticity Diagram, and represents the color of the lamp.
2. Θ1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity.
3. The luminous intensity is measured on the mechanical axis of the lamp package.
4. The optical axis is closely aligned with the package mechanical axis.
5. Tinting of amber lamps is yellow, red-orange lamps are tinted a reddish orange, and red lamps are tinted red.
Package Dimensions
2.35 (0.093)
MAX.
5.00 ± 0.20
(0.197 ± 0.008)
31.60
(1.244) MIN. 0.70 (0.028)
MAX.
1.00
(0.039)MIN. 0.50 ± 0.10
(0.020 ± 0.004)SQ. TYP.
CATHODE
LEAD
8.71 ± 0.20
(0.343 ± 0.008
1.14 ± 0.20
(0.045 ± 0.008)
5.80 ± 0.20
(0.228 ± 0.008)
CATHODE
FLAT 2.54 ± 0.38
(0.100 ± 0.015)
3.60
0.65 MAX.
0.44 ± 0.2
+ 0.1
– 0
0.4
2.54 ± 0.3
1.0 MIN.
23.0 MIN.
0.8 MAX.
(MENISCUS)
2.00
5.70 ± 0.5
3.10 ± 0.20
3.80 ± 0.30
3.35 ± 0.30
AB
3
Electrical/Optical Characteristics at TA = 25°C
Parameter Symbol Min. Typ. Max. Units Test Conditions
Forward Voltage IF = 20 mA
Amber (λd = 590 nm) 2.02
Red-Orange (λd = 615 nm) VF1.94 2.4 V
Red (λd = 626 nm) 1.90
Reverse Voltage VR520 VI
R
= 100 µA
Peak Wavelength Peak of Wavelength of
Amber 592 Spectral Distribution
Red-Orange λPEAK 621 nm at IF = 20 mA
Red 635
Spectral Halfwidth ∆λ1/2 17 nm Wavelength Width at
Spectral Distribution
1/2 Power point at
IF = 20 mA
Speed of Response τs20 ns Exponential Time
Constant, e-t/τs
Capacitance C 40 pF VF = 0, f = 1 MHz
Thermal Resistance RΘJ-PIN 240 °C/W LED Junction-to-Cathode
Lead
Luminous Efficacy[5] Emitted Luminous
Amber 500 Power/Emitted Radiant
Red-Orange ηv235 lm/W Power
Red 155
Note:
1. The radiant intensity, Ie, in watts per steridian, may be found from the equation Ie = Iv/ηv, where Iv is the luminous intensity in
candelas and ηv is the luminous efficacy in lumens/watt.
Absolute Maximum Ratings at TA = 25°C
Parameter 5 mm 3 mm
DC Forward Current 50 mA[1,3,4] 30 mA[2,3,4]
Peak Pulsed Forward Current [3,4] 70 mA 50 mA
Average Forward Current 30 mA 30 mA
Reverse Voltage (IR = 100 µA) 5 V 5 V
LED Junction Temperature 130°C 110°C
Operating Temperature -40°C to +100°C -40°C to +80°C
Storage Temperature -40°C to +120°C -40°C to +85°C
Dip/Drag Solder Temperature 260°C for 5 seconds
Wave Solder Temperature 245°C for 3 seconds
[1.59 mm (0.060 in.) below seating plane]
Notes:
1. Derate linearly as shown in Figure 4.
2. Derate linearly as shown in Figure 5.
3. For long term performance with minimal light output degradation, drive currents between 10 and 30 mA are recommended.
4. Please contact your Agilent sales representative about operating currents below 10 mA.
44
Figure 2. Forward Current vs.
Forward Voltage.
Figure 3. Relative Luminous Intensity
vs. Forward Current. Figure 4. Maximum Forward Current
vs. Ambient Temperature for 5 mm
Lamps. Derating Based on T JMAX =
130°C.
Figure 5. Maximum Forward Current
vs. Ambient Temperature for 3 mm
Lamps. Derating Based on T JMAX =
110°C.
Figure 1. Relative Intensity vs. Peak Wavelength.
WAVELENGTH – nm
RELATIVE INTENSITY
550 600 650 700
1.0
0.5
0
AMBER RED-ORANGE
RED
CURRENT – mA
1.0
0
V
F
– FORWARD VOLTAGE – V
2.5
40
30
1.5 2.0
60
3.0
10
20
50 AMBER
70
RED
RELATIVE LUMINOUS INTENSITY
(NORMALIZED AT 20 mA)
0
0
IF – DC FORWARD CURRENT – mA
40
2.5
2.0
1.0
0.5
20 60
3.0
1.5
I
F
– FORWARD CURRENT – mA
0
0
T
A
– AMBIENT TEMPERATURE – °C
40 80
50
40
30
20
10
20 60 100
Rθ
JA
= 585° C/W
Rθ
JA
= 780° C/W
I
F
– FORWARD CURRENT – mA
0
0
T
A
– AMBIENT TEMPERATURE – °C
30 80
30
20
10
20 50 90
Rθ
JA
= 500° C/W
Rθ
JA
= 660° C/W
10 40 60 70
5
Figure 7. Representative Spatial Radiation Pattern for 30°
Viewing Angle T-1 3/4 (5 mm) Lamps (HLMP-WX27).
Figure 8. Representative Spatial Radiation
Pattern for 65° Viewing Angle Tinted/Diffused
T-1 3/4 (5 mm) Lamps (HLMP-WX02).
Figure 6. Representative Spatial Radiation Pattern for 15°
Viewing Angle T-1 3/4 (5 mm) Lamps (HLMP-WX12).
NORMALIZED INTENSITY – %
1.0
0
ANGULAR DISPLACEMENT – DEGREES
0.8
0.6
0.5
0.7
0.2
-80 -60
0.1
0.3
0.4
-40 0 20 40 60 80 100
0.9
-100 -20
RELATIVE INTENSITY – %
1.0
0
ANGULAR DISPLACEMENT – DEGREES
0.8
0.6
0.5
0.7
0.2
-20 -15
0.1
0.3
0.4
-10 0 5 10 15 20 25
0.9
-25 -5
RELATIVE INTENSITY – %
1.0
0
ANGULAR DISPLACEMENT – DEGREES
0.8
0.6
0.5
0.7
0.2
-20 -15
0.1
0.3
0.4
-10 0 5 10 15 20 25
0.9
-25 -5
Figure 9. Representative Spatial Radiation
Pattern for 60° Viewing Angle T-1 (3 mm) Lamps
(HLMP-NL06/NH04/NG07).
NORMALIZED INTENSITY – %
100
0
ANGULAR DISPLACEMENT – DEGREES
80
60
50
70
20
-70 -50
10
30
40
-40 0 20 40 60 80 90
90
-90 -20 -10-30-60-80 10 30 50 70
6
www.semiconductor.agilent.com
Data subject to change.
Copyright © 1999 Agilent Technologies, Inc.
Obsoletes 5965-9780E (7/97)