DRA4 MCX Series
• 54mm Four Channel DIN Rail Mount SSR Assembly
• AC Ratings up to 280 VAC and 5 Amps
• 3-15 and 15-32VDC control
• Cage style screw terminals for easy connection
• Fits standard 35mm DIN rail
• Includes LED Status indicator
PRODUCT SELECTION
Description 5 A
3-15 VDC Control DRA4-MCX240D5
15-32 VDC Control DRA4-MCXE240D5
OUTPUT SPECIFICATIONS (1)
Description DRA4-MCX(E)240x5
Operating Voltage [VAC] 12-280
Transient Overvoltage [Vpk] 600
Maximum Load Current [Arms] (2) 5
Minimum Load Current [Arms] 0.06
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1
Minimum off-state dv/dt @ maxi mum rated voltage [V/µsec] (3) 500
Maximum 1 Cycle Surge Current (50/60 Hz) [Apk] 239/250
Maximum I²t for fusing (50/60 Hz, 1/2 cycle) [A² sec] 285/260
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.4
INPUT SPECIFICATIONS (1)
Description DRA4-MCX DRA4-MCXE
Control Voltage Range 3-15 VDC 15-32 VDC
Must Turn On Voltage 3.0 VDC 15.0 VDC
Must Turn Off Voltage 1 .0 VDC 1 .0 VDC
Typycal Input Current 15 mAdc 15 mAdc
Nominal Input Impedance 300 Ohm 1500 Ohm
Maximum Turn-On Time [msec] 1/2 Cycle 1/2 Cycle
Maximum Turn-Off Time [µsec] 1/2 Cycle 1/2 Cycle
GENERAL SPECIFICATIONS
Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 VRMS
Minimum Insulation Resistance (@ 500 VDC) 109 Ohms
Maximum Capacitance, Input/Output 10 pF
Ambient Operating Temperature Range -40 to 80°C
Ambient Storage Temperature Range -40 to 125 °C
Weight (typical) 0.32 lb (145.5g)
Encapsulation Themall y Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) See derating chart on page 3
3) Off-Stat e dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
E116949 (relay only)
Rv. 110811
ANNEX - ENVIROMENTAL INFORMATION