SURFACE MOUNT BRIDGE RECTIFIERS DF15005S - DF1510S PRV : 50 - 1000 Volts Io : 1.5 Ampere DFS 0.205(5.2) 0.195(5.0) FEATURES : * * * * * * * High current capability High surge current capability High reliability Low reverse current Low forward voltage drop Ideal for printed circuit board Pb / RoHS Free ~ ~ 0.404(10.3) 0.386(9.80) 0.047(1.20) 0.040(1.02) 0.335(8.51) 0.320(8.13) MECHANICAL DATA : 0.255(6.5) 0.245(6.2) 0.122(3.1) 0.102(2.6) * Case : Molded plastic * Epoxy : UL94V-O rate flame retardant * Terminals : Plated Lead solderable per MIL-STD-750, Method 2026 * Polarity : Polarity symbols marked on body * Mounting position : Any * Weight : 0.4 gram 0.060(1.524) 0.040(1.016) 0.013(0.330) 0.009(0.241) Dimensions in inches and ( millimeters ) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating at 25C ambient temperature unless otherwise specified. 60 Hz, resistive or inductive load. RATING SYMBOL DF DF DF DF DF DF DF 15005S 1501S 1502S 1504S 1506S 1508S 1510S UNIT Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 V Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 V Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 V Maximum Average Forward Output Rectified Current at Ta = 40C Maximum Peak Forward Surge Current Single half sine wave Superimposed on rated load (JEDEC Method) IF(AV) 1.5 A IFSM 50 A Current Squared Time at t < 8.3 ms. I2t 10 A 2S Maximum Instantaneous Forward Voltage per element at IF = 1.5 A VF 1.1 V Maximum DC Reverse Current Ta = 25C IR 5.0 A at Rated DC Blocking Voltage Ta = 125C IR(H) 500 A Cj 25 pF RJA 40 C/W TJ, TSTG - 55 to + 150 C Typical Junction Capacitance per element (Note 1) Typical Thermal Resistance (Note 2) Junction and Storage Temperature Range Notes : (1) Measured at 1.0 MHz and applied reverse voltage of 4.0VDC (2) Units mounted on P.C.B. with 0.51 x 0.51" (13 x 13mm) copper pads Page 1 of 2 Rev. 03: September 26, 2005 RATING AND CHARACTERISTIC CURVES ( DF15005S - DF1510S ) FIG.2 - MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT PER BRIDGE ELEMENT 1.5 50 PEAK FORWARD SURGE CURRENT, AMPERES AVERAGE FORWARD OUTPUT CURRENT, AMPERES FIG.1 - DERATING CURVE FOR OUTPUT RECTIFIED CURRENT 1.2 0.9 0.6 60Hz RESISTIVE OR INDUCTIVE LOAD 0.3 0 0 25 50 75 100 125 150 40 30 TJ = 150C 20 SINGLE SINE-WAVE (JEDEC METHOD) 10 0 175 1 2 4 6 10 20 40 60 100 NUMBER OF CYCLES AT 60Hz AMBIENT TEMPERATURE, ( C) FIG.3 - TYPICAL FORWARD CHARACTERISTICS FIG.4 - TYPICAL REVERSE CHARACTERISTICS PER BRIDGE ELEMENT 100 1 Pulse Width = 300 s 2% Duty Cycle 0.1 TJ = 25C 0.01 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 REVERSE CURRENT, MICROAMPERES FORWARD CURRENT, AMPERES 10 TJ = 125 C 10 1.0 TJ = 25 C 0.1 FORWARD VOLTAGE, VOLTS 0.01 0 20 40 60 80 100 120 140 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) Page 2 of 2 Rev. 03 : September 26, 2005