Characteristics
Standard Relays
Item 1
pole
2 pole
Contact resistance
30 m
Ω
max.
50 m
Ω
max.
Operate (set) time 15 ms max.
Release (reset) time
AC: 10 ms max.; DC: 5 ms max.
Max. operating frequency
Mechanical:
18,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
Ω
min. (at 500 VDC)
Dielectric withstand
voltage
5,000 V
AC, 50/60 Hz for 1 min between coil and
contacts;
1,000 V
AC, 50/60 Hz for 1 min between contacts
of same polarity
5,000 V
AC, 50/60 Hz for 1 min between coil and
contacts;
3,000 V
AC, 50/60 Hz for 1 min between
contacts of dif
ferent polarity
1,000 V
AC, 50/60 Hz for 1 min between
contacts of same polarity
V
ibration resistance
Destruction:
10 to 55 Hz, 1.5-mm double amplitude
Malfunction:
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction:
1,000 m/s
2
(approx. 100G)
Malfunction:
200 m/s
2
when energized (approx. 20G); 100m/s
2
when not energized (approx. 10G)
Life expectancy
Mechanical:
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature
Operating: –40_
C to 70
_
C (with no icing)
Storage: –40
_
C to 70
_
C (with no icing)
Ambient humidity
Operating: 35% to 85%
Weight
Approx. 17 g
Double-winding Latching Relays
Item 1
pole
2 poles
Contact resistance
30 m
Ω
max.
50 m
Ω
max.
Set time
20 ms max.
Reset time
20 ms max.
Min. set/reset signal width
30 ms max.
Max. operating frequency
Mechanical:
18,000 operations/hr Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
Ω
min. (at 500 VDC)
Dielectric withstand
voltage
5,000 V
AC, 50/60 Hz for 1 min between coil and
contacts;
1,000 V
AC, 50/60 Hz for 1 min between contacts
of same pole;
1,000 V
AC, 50/60 Hz for 1 min between set and
reset coil
5,000 V
AC, 50/60 Hz for 1 min between coil and
contacts;
3,000 V
AC, 50/60 Hz for 1 min between contacts
of dif
ferent poles
1,000 V
AC, 50/60 Hz for 1 min between contacts
of same pole
1,000 V
AC, 50/60 Hz for 1 min between set and
reset coil
V
ibration resistance
Destruction:
10 to 55 Hz, 1.5 mm double amplitude
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance
Destruction:
1,000 m/s
2
(approx. 100G)
Malfunction: Set:
500 m/s
2
(approx. 50G); 200m/s
2
(approx. 20G)
Reset: 100 m/s
2
(approx. 10G)
Life expectancy
Mechanical:
10,000,000 operations min (at 18,000 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr under rated load)
Weight
Approx. 17 g