- 228 -
BY396 THRU BY399
3.0 AMPS. Fast Recovery Rectifiers
Voltage Range
100 to 800 Volts
Current
3.0 Amperes
Features
a Low forward voltage drop
a High current capability
a High reliability
a
High surge current capability
Mechanical Data
a Cases: Molded plastic
a Epoxy: UL 94V-0 rate flame retardant
a Lead: Axial leads, solderable per MIL-
a Lead: STD-202, Method 208 guaranteed
a Polarity: Color band denotes cathode end
a High temperature soldering guaranteed:
250°C/10 seconds/.375”,(9.5mm) lead
lengths at 5 lbs.,(2.3kg) tension
a
Weight: 1.2 grams
DO-201AD
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25°C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Type Number BY396 BY397 BY398 BY399 Units
Maximum Recurrent Peak Reverse Voltage 100 200 400 800 V
Maximum RMS Voltage 70 140 280 560 V
Maximum DC Blocking Voltage 100 200 400 800 V
Maximum Average Forward Rectified Current
.375”(9.5mm) Lead Length @TA = 55°C 3.0 A
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated Load
(JEDEC method ) 150 A
Maximum Instantaneous Forward Voltage
@ 3.0A 1.2 V
Maximum DC Reverse Current @ TA=25°C
at Rated DC Blocking Voltage @ TA=100°C 10
150 uA
uA
Maximum Reverse Recovery Time ( Note 1 ) 250 nS
Typical Junction Capacitance ( Note 2 ) 60 pF
Operating Temperature Range TJ -65 to +150 °C
Storage Temperature Range TSTG -65 to +150 °C
Notes:1. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A, IRR=0.25A
Notes:2. Measured at 1 MHz and Applied Reverse Voltage of 4..0 Volts D.C.