Relays & Sockets Switches & Pilot Lights RV8H and RV8S 6mm and 14mm Slim Interface Relay Key features: Electromechanical Screw Terminal Solid State Spring Clamp Terminal * Class I, Division 2 and Class I, Zone 2 Hazardous Location options (electromechanical relays only) * Solid State relay versions available (6mm only) Signaling Lights * Only 70mm in height from DIN rail * Gold-plated contacts (electrical mechanical relays only) * Pre-assembled relay and DIN mount socket * Universal screw terminals (flat and phillips) or spring clamp terminals * Universal AC/DC socket with built-in surge suppression and green LED * 6A-16A contact rating (electromechanical relays only) Relays & Sockets * Lever for easy locking and removal of relay * Operating temperature of -40C ~ +70C (-20C ~ +60C for SSR) 6mm wide * RoHS compliant 6mm wide * General Specifications Contactors Timers Electromechanical Standard/ Hazardous Location C1D2 Ratings Class I, Division 2, Groups A, B, C, D, T4A Class I, Zone 2 AEx nA nC IIC T4 Class I, Zone 2 Ex nA nC IIC T4 X Gc UL/c-UL Listed UL/c-UL Listed, Number of Poles 1 Pole 1 Pole Contact Configuration 1C (SPDT) 1A (SPST) Contact Material AgNi (Au plating) MOSFET, Transistor or Triac Degree of Protection Dielectric Strength Terminal Blocks Vibration Resistance Circuit Breakers Solid State Shock Resistance IP20 IP20 Between Contact and Coil 4,000V AC for 1 minute 2,500V AC for 1 minute Between Pole 1,000V AC for 1 minute - Operating Extremes Frequency 10 to 55Hz, Amplitude 0.5mm (NO contact), 0.2mm (NC contact) Frequency 10 to 55Hz, Amplitude 1.0mm Damage Limits Operating Extremes NO: 49m/s NC: 29.4m/s Damage Limits 980m/s 980m/s2 Mechanical Life (no load) Over 10,000,000 operations (operation frequency 18,000 operations per hour) - Operating Temperature -40 to +70C no freezing (-40 to +55C for AD110 and AD220 coil voltages) -20 to +60C Operating Humidity 5 to 85% (no condensation) 5 to 85% (no condensation) Weight (approx.) Screw Terminal: 30g, Spring Clamp Terminal: 26g Screw Terminal: 30g, Spring Clamp Terminal: 26g 840 www.IDEC.com 1705151135 Relays & Sockets RV8H and RV8S Switches & Pilot Lights RV8 Series 14mm Width Key features: Top View with Marking Plate * Class I, Division 2 and Class I, Zone 2 Hazardous Location options Screw Terminal Spring Clamp Terminal * Space-saving 14mm width. * Universal AC/DC socket with surge suppression and green LED Indicator * Gold plated contacts (2-pole model only) * Pre-assembled relay and DIN mount socket Signaling Lights * Universal screw terminals (flat and Philips) or spring clamp terminals * Only 70 mm in height from DIN rail * Release lever for easy locking and removal of relay * Wide input voltage range: 6 to 240V * High dielectric strength and impulse withstand voltages. * Reverse polarity protected * RoHS compliant Relays & Sockets Specifications Number of Poles 1 Pole 2 Pole Class I, Division 2, Groups A, B, C, D, T4 Class I, Zone 2 AEx nA nC IIC T4 Class I, Zone 2 Ex nA nC IIC T4 X Gc UL/c-UL Listed Contact Configuration 1C (SPDT) 2C (DPDT) Contact Material AgNi AgNi (Au-plated) Degree of Protection IP20 5,000V AC for 1 minute IP20 Dielectric strength Between contact and coil Between contacts of the same pole Timers Ratings 1,000V AC for 1 minute Between contact sets - 2,500V AC for 1 minute Vibration Resistance Operating extremes Damage limits Frequency 10 to 55Hz, Amplitude 0.75mm (NO contact), 0.175mm (NC contact) Frequency 10 to 55Hz, Amplitude 0.75mm (NO contact), 0.1mm (NC contact) Shock Resistance Operating extremes NO: 98m/s Damage limits 980m/s NC: 24.5m/s AC load:30,000 operations minimum (250V AC, 12A resistive load, operation frequency 360 operation per hour) Mechanical Life (no load) Over 10,000,000 operations (Operation frequency 18,000 operations per hour) RV8H-1L1-D6, D9, D12, D18, D24, AD12, AD18, AD24, AD48, AD60, AD110 : -40 to +70C (Contact current 12A max, 6A per terminal) no freezing : -40 to +55C (Contact current 16A max, 8A per terminal) no freezing Operating Temperature RV8H-1L1- AD220 : -40 to +55C (Contact current 16A max, 8A per terminal) no freezing RV8H-1S1-D6, D9, D12, D18, D24, AD12, AD18, AD24, AD48, AD60, AD110 : -40 to +70C (Contact current 12A max, 6A per terminal) no freezing Operating Humidity Weight (approx.) 1705151135 800-262-IDEC (4332) * USA & Canada Circuit Breakers Screw Terminal: 52g Spring Clamp Terminal: 49g Electrical Life - Spring Clamp terminal Terminal Blocks 5 to 85% (no condensation) Screw Terminal: 52g Spring Clamp Terminal: 49g Electrical Life - Screw terminal Contactors RV8H-1S1- AD220 : -40 to +55C (Contact current 12A max, 6A per terminal) no freezing 980m/s AC load:100,000 operations minimum (250V AC, 8A resistive load, ozperation frequency 360 operation per hour) AC load:100,000 operations minimum (250V AC, 6A resistive load, operation frequency 360 operation per hour) Over 10,000,000 operations (Operation frequency 18,000 operations per hour) RV8H-2L-D6, D9, D12, D18, D24, AD12, AD18, AD24, AD48, AD60, AD110 : -40 to +70C (Contact current 6A max) no freezing : -40 to +55C (Contact current 8A max) no freezing RV8H-2L- AD220 : -40 to +55C (Contact current 8A max) no freezing RV8H-2S-D6, D9, D12, D18, D24, AD12, AD18, AD24, AD48, AD60, AD110 : -40 to +70C (Contact current 6A max) no freezing RV8H-2S- AD220 : -40 to +55C (Contact current 6A max) no freezing AC load:30,000 operations minimum (250V AC, 16A resistive load, operation frequency 360 operation per hour) 841 Relays & Sockets Screw Terminal Input Voltage Contactors Timers Relays & Sockets DC AC/ DC General Purpose Spring Clamp Terminal Hazardous Location (C1D2) Hazardous Location (C1D2) General Purpose 6V RV8H-L-D6 RV8H-L-D6-C1D2 RV8H-S-D6z RV8H-S-D6-C1D2 9V RV8H-L-D9 RV8H-L-D9-C1D2 RV8H-S-D9 RV8H-S-D9-C1D2 12V RV8H-L-D12 RV8H-L-D12-C1D2 RV8H-S-D12 RV8H-S-D12-C1D2 18V RV8H-L-D18 RV8H-L-D18-C1D2 RV8H-S-D18 RV8H-S-D18-C1D2 24V RV8H-L-D24 RV8H-L-D24-C1D2 RV8H-S-D24 RV8H-S-D24-C1D2 12V RV8H-L-AD12 RV8H-L-AD12-C1D2 RV8H-S-AD12 RV8H-S-AD12-C1D2 18V RV8H-L-AD18 RV8H-L-AD18-C1D2 RV8H-S-AD18 RV8H-S-AD18-C1D2 24V RV8H-L-AD24 RV8H-L-AD24-C1D2 RV8H-S-AD24 RV8H-S-AD24-C1D2 48V RV8H-L-AD48 RV8H-L-AD48-C1D2 RV8H-S-AD48 RV8H-S-AD48-C1D2 60V RV8H-L-AD60 RV8H-L-AD60-C1D2 RV8H-S-AD60 RV8H-S-AD60-C1D2 110V - 125V RV8H-L-AD110 RV8H-L-AD110-C1D2 RV8H-S-AD110 RV8H-S-AD110-C1D2 220V - 240V RV8H-L-AD220 RV8H-L-AD220-C1D2 RV8H-S-AD220 RV8H-S-AD220-C1D2 6mm Solid State Relay Input Voltage 6V Terminal Blocks DC 24V 120V Circuit Breakers Part Numbers 6mm Electromechanical Relay Signaling Lights Switches & Pilot Lights RV8H and RV8S AC 240V 842 Screw Terminal Spring Clamp Terminal Part Number Part Number Output Voltage 24V DC, 3.5A RV8S-L-D24-D6 RV8S-S-D24-D6 48V DC, 0.1A RV8S-L-D48-D6 RV8S-S-D48-D6 240V AC, 2A zero cross RV8S-L-A240Z-D6 RV8S-S-A240Z-D6 240V AC, 2A random RV8S-L-A240-D6 RV8S-S-A240-D6 24V DC, 3.5A RV8S-L-D24-D24 RV8S-S-D24-D24 48V DC, 0.1A RV8S-L-D48-D24 RV8S-S-D48-D24 240V AC, 2A zero cross RV8S-L-A240Z-D24 RV8S-S-A240Z-D24 240V AC, 2A random RV8S-L-A240-D24 RV8S-S-A240-D24 24V DC, 3.5A RV8S-L-D24-A120 RV8S-S-D24-A120 48V DC, 0.1A RV8S-L-D48-A120 RV8S-S-D48-A120 240V AC, 2A zero cross RV8S-L-A240Z-A120 RV8S-S-A240Z-A120 240V AC, 2A random RV8S-L-A240-A120 RV8S-S-A240-A120 24V DC, 3.5A RV8S-L-D24-A240 RV8S-S-D24-A240 48V DC, 0.1A RV8S-L-D48-A240 RV8S-S-D48-A240 240V AC, 2A zero cross RV8S-L-A240Z-A240 RV8S-S-A240Z-A240 240V AC, 2A random RV8S-L-A240-A240 RV8S-S-A240-A240 www.IDEC.com 1705151135 Relays & Sockets RV8H and RV8S Screw Terminal General Purpose 2 Pole 1 Pole 2 Pole General Purpose 1 Pole 2 Pole Hazardous Location (C1D2) 1 Pole 2 Pole 6V RV8H-1L1-D6 RV8H-2L-D6 RV8H-1L1-D6-C1D2 RV8H-2L-D6C1D2 RV8H-1S1-D6 RV8H-2S-D6 RV8H-1S1-D6-C1D2 RV8H-2S-D6C1D2 9V RV8H-1L1-D9 RV8H-2L-D9 RV8H-1L1-D9-C1D2 RV8H-2L-D9C1D2 RV8H-1S1-D9 RV8H-2S-D9 RV8H-1S1-D9-C1D2 RV8H-2S-D9C1D2 12V RV8H-1L1-D12 RV8H-2L-D12 RV8H-1L1-D12-C1D2 RV8H-2L-D12C1D2 RV8H-1S1-D12 RV8H-2S-D12 RV8H-1S1-D12-C1D2 RV8H-2S-D12C1D2 18V RV8H-1L1-D18 RV8H-2L-D18 RV8H-1L1-D18-C1D2 RV8H-2L-D18C1D2 RV8H-1S1-D18 RV8H-2S-D18 RV8H-1S1-D18-C1D2 RV8H-2S-D18C1D2 24V RV8H-1L1-D24 RV8H-2L-D24 RV8H-1L1-D24-C1D2 RV8H-2L-D24C1D2 RV8H-1S1-D24 RV8H-2S-D24 RV8H-1S1-D24-C1D2 RV8H-2S-D24C1D2 12V RV8H-1L1-AD12 RV8H-2L-AD12 RV8H-1L1-AD12-C1D2 RV8H-2L-AD12C1D2 RV8H-1S1-AD12 RV8H-2S-AD12 RV8H-1S1-AD12C1D2 RV8H-2S-AD12C1D2 18V RV8H-1L1-AD18 RV8H-2L-AD18 RV8H-1L1-AD18-C1D2 RV8H-2L-AD18C1D2 RV8H-1S1-AD18 RV8H-2S-AD18 RV8H-1S1-AD18C1D2 RV8H-2S-AD18C1D2 24V RV8H-1L1-AD24 RV8H-2L-AD24 RV8H-1L1-AD24C1D2 RV8H-2L-AD24C1D2 RV8H-1S1-AD24 RV8H-2S-AD24 RV8H-1S1-AD24C1D2 RV8H-2S-AD24C1D2 48V RV8H-1L1-AD48 RV8H-2L-AD48 RV8H-1L1-AD48C1D2 RV8H-2L-AD48C1D2 RV8H-1S1-AD48 RV8H-2S-AD48 RV8H-1S1-AD48C1D2 RV8H-2S-AD48C1D2 60V RV8H-1L1-AD60 RV8H-2L-AD60 RV8H-1L1-AD60C1D2 RV8H-2L-AD60C1D2 RV8H-1S1-AD60 RV8H-2S-AD60 RV8H-1S1-AD60C1D2 RV8H-2S-AD60C1D2 110V - 125V RV8H-1L1-AD110 RV8H-2L-AD110 RV8H-1L1-AD110C1D2 RV8H-2L-AD110C1D2 RV8H-1S1-AD110 RV8H-2S-AD110 RV8H-1S1-AD110C1D2 RV8H-2S-AD110C1D2 220V - 240V RV8H-1L1-AD220 RV8H-2LAD220 RV8H-1L1-AD220C1D2 RV8H-2L-AD220C1D2 RV8H-1S1AD220 RV8H-2S-AD220 RV8H-1S1-AD220C1D2 RV8H-2S-AD220C1D2 Timers AC/ DC Hazardous Location (C1D2) Relays & Sockets DC 1 Pole Spring Clamp Terminal Signaling Lights Input voltage Switches & Pilot Lights 14 mm Electromechanical Relay Contactors Terminal Blocks Circuit Breakers 1705151135 800-262-IDEC (4332) * USA & Canada 843 Relays & Sockets Signaling Lights Switches & Pilot Lights RV8H and RV8S Ratings 6mm Electromechanical Coil Ratings DC Timers Relays & Sockets AC/ DC Circuit AC Resistance 15% ()1 (at 23C) Operating Characteristics Circuit DC Resistance 15% ()1 (at 23C) Rated Voltage Rated Current 15% (mA)1 (at 23C) 6V 35 - 170 9V 18.6 - 485 12V 14.6 - 820 18V 11.6 - 1550 0.2 24V 10.6 - 2270 0.25 12V 15.5 755 800 0.2 18V 13.3 1365 1345 0.25 24V 13.7 1730 1790 48V 4 11880 12230 60V 3.4 17600 17910 0.2 110V - 125V 3.4 - 3.9 31790 - 31890 32450 - 32900 0.5 220V - 240V 3.3 - 3.6 65670 - 66070 65940 - 68570 0.85 Dropout Voltage (at 23C) Pickup Voltage (at 23C) Maximum Allowable Voltage (at 23C) Power Consumption (W) 0.21 0.2 90% max 7% min 110% 0.2 0.33 90% max 7% min 110% 0.2 Note 1 10% for 6V, 9V and 12V 6mm Electromechanical Contact Ratings Allowable Contact Power Resistive Load 1500VA, 180W DC Rated Load Resistive Load 250V AC 6A, 30V DC 6A Allowable Switching Current 6A Allowable Switching Voltage 400V AC, 125V DC Allowable Switching Power 1500VA, 180W DC Minimum Applicable Load 6V DC/10mA 6mm Solid State Input Ratings Circuit Breakers Terminal Blocks Contactors Type Zero Crossing Random Crossing Control Voltage Range Output / Input Voltage Pickup Voltage Dropout Voltage Input Current Maximum Operation Time Maximum Release Time 4.5-12V DC 24V DC / 6V DC 4.5V DC 1.5V DC 10mA10%(6VDC) 120s 200s 19.6-30V DC 24V DC / 24V DC 19.6V DC 5V DC 9mA10%(24VDC) 350s 200s 96-132V AC 24V DC / 120V AC 96V AC 12V AC 10mA10%(120VAC) 11ms 14ms 192-264V AC 24V DC / 240V AC 192V AC 24V AC 10mA10%(240VAC) 11ms 14ms 4.5-12V DC 48V DC / 6V DC 4.5V DC 1.5V DC 6mA10%(6VDC) 40s 300s 19.6-30V DC 48V DC / 24V DC 19.6V DC 5V DC 7mA10%(24VDC) 40s 300s 96-132V AC 48V DC / 120V AC 96V AC 12V AC 10mA10%(120VAC) 8ms 14ms 192-264V AC 48V DC / 240V AC 192V AC 24V AC 10mA10%(240VAC) 8ms 14ms 4.5-12V DC 240V AC / 6V DC 4.5V DC 2V DC 15mA10%(6VDC) 10ms 10ms 19.6-30V DC 240V AC / 24V DC 19.6V DC 5V DC 7mA10%(24VDC) 10ms 10ms 96-132V AC 240V AC / 120V AC 96V AC 12V AC 10mA10%(120VAC) 16ms 20ms 192-264V AC 240V AC / 240V AC 192V AC 24V AC 10mA10%(240VAC) 16ms 20ms 4.5-12V DC 240V AC / 6V DC 4.5V DC 2V DC 15mA10%(6VDC) 300s 10ms 19.6-30V DC 240V AC / 24V DC 19.6V DC 5V DC 7mA10%(24VDC) 300s 10ms 96-132V AC 240V AC / 120V AC 96V AC 12V AC 10mA10%(120VAC) 8ms 20ms 192-264V AC 240V AC / 240V AC 192V AC 24V AC 10mA10%(240VAC) 8ms 20ms 844 www.IDEC.com 1705151135 Relays & Sockets RV8H and RV8S 24V DC 48V DC 240V AC Output Device MOSFET Photo-transistor Triac Operating Voltage Range 0-24V DC 0-48V DC 24-280V AC (47-63Hz) Maximum Load Current 3.5A 100mA 2A Minimum Load Current 1mA 1mA 70mA Maximum Blocking Voltage 30V DC 60V DC 600V AC Maximum Surge Current 9A (10ms) 300mA (10ms) 120A pk (16.6ms) Maximum l2t for Fusing - - 60A sec Typical On-State Leakage Current 0.4V 1V 1.1V (peak) Maximum Off-State Leakage Current 0.001mA 0.001mA 4mA Switching Configuration Normally Open Normally Open Normally Open Signaling Lights Typical Input Voltage Switches & Pilot Lights 6mm Solid State Output Ratings Relays & Sockets 14mm Electromechanical Coil Ratings Rated Current 15% (mA)1 (at 23C) Rated Voltage DC DC AC 50Hz AC 60Hz Pickup Voltage (at 23C) Dropout Voltage (at 23C) Maximum Allowable Voltage (at 23C) Maximum Allowable Voltage2 Operation and release time Power Consumption (W) AC (50Hz) DC AC (60Hz) 0.45 - - 0.40 - - 0.38 - - 0.43 - - 0.48 - - 0.38 0.35 0.35 0.43 0.43 0.43 0.48 0.50 0.50 0.36 0.43 0.43 0.46 0.54 0.54 21552 0.64 0.73 0.73 43636 1.10 1.25 1.32 6V 75.0 80 9V 44.0 205 12V 32.0 375 18V 24.0 750 24V 20.0 12V 32.0 29.0 29.0 375 414 414 18V 24.0 24.0 24.0 750 750 750 24V 20.0 21.0 21.0 1200 1143 1143 48V 7.6 9.0 9.0 6316 5333 5333 60V 7.6 9.0 9.0 7895 6667 6667 110V 125V 4.4~5.1 5.3-5.8 5.3-5.8 24510 21552 220V 240V 4~4.6 4.5-5.2 4.8-5.5 52174 46154 120% 1200 80% max 7% min 110% 110% 2 15ms max Contactors AC/ DC AC 60Hz Operating Characteristics (Against Rated Voltage) Timers DC AC 50Hz Circuit AC Resistance 15% ()1 (at 23C) Note 1: Input voltages lower than 24V: 10% Note 2: At rated operating temperature Terminal Blocks Circuit Breakers 1705151135 800-262-IDEC (4332) * USA & Canada 845 Relays & Sockets Switches & Pilot Lights RV8H and RV8S 14mm Contact Ratings Screw Terminal Allowable contact power Relays & Sockets 1 Pole 3,000VA 2 Pole 2,000VA 2 Pole 1,500VA B300 (pilot duty) B300 (pilot duty) Resitive load 1 Pole 250V AC, 16A (8A per terminal) at 55C, 12A (6A per terminal) at 70C 1 Pole 250V AC, 12A (6A per terminal) at 70C 2 Pole 250V AC, 8A at 55C, 6A at 70C 2 Pole 250V AC, 6A at 70C B300 (pilot duty) B300 (pilot duty) Allowable Switching Current 1 Pole 16A (8A per terminal) at 55C, 12A (6A per terminal) at 70C 1 Pole 12A (6A per terminal) at 70C 2 Pole 8A at 55C, 6A at 70C 2 Pole 6A at 70C Allowable Switching Power 1 Pole 4,000VA 1 Pole 3,000VA 2 Pole 2,000VA 2 Pole 1,500VA 1 Pole 6VDC 100mA 1 Pole 6VDC 100mA 2 Pole 5VDC 10mA 2 Pole 5VDC 10mA Inductive load Minimum Applicable Load (reference value) Timers 1 Pole 4,000VA Inductive load Rated Load Signaling Lights Resistive load Spring Clamp Terminal Accessories Jumper, Spacer, and Screwdriver Spacer (circuit separator) 5, 6 6mm Color Part Number Jumper for 6mm Relay (20 combs) 1, 2, 6 Black SV9Z-J20B Gray SV9Z-J20W Blue SV9Z-J20S SV9Z-SA2W Screwdriver 14mm Contactors Jumper for 14mm Relay (32 combs, with 2 combs per relay, or 16 discrete relays.) 3, 4, 6 Black SV9Z-J232B Gray SV9Z-J232W SV9Z-J232S 1. Jumper combs come with 20 points for 6mm relays. If shorter lengths are needed, simply cut off the excess points. 2.Ensure that the total current to the jumper does not exceed the overall rated current (Rated current: 6A). 3.Jumper combs come with 16 pairs of combs for 14mm relays. If shorter lengths are needed, simply cut off the excess points. 4.Ensure that the total current to the jumper does not exceed the overall rated current (Rated current: 6A for spring-clamp terminals and 8A for screw type terminations). 5.Width of spacer: 2mm 6.When using a cut jumper, please use a spacer on the cut side. For additional information see instruction sheet. Circuit Breakers Terminal Blocks Blue BC1S-SD0 846 www.IDEC.com 1705151135 Relays & Sockets 14mm Part Number Engraving blank SV9Z-PW10-1-10 1-10 SV9Z-PW10-11-20 11-20 SV9Z-PW10-21-30 21-30 SV9Z-PW10-31-40 31-40 SV9Z-PW10-41-50 41-50 SV9Z-PW10-51-60 51-60 SV9Z-PW10-61-70 61-70 SV9Z-PW10-71-80 71-80 SV9Z-PW10-81-90 81-90 SV9Z-PW10-91-100 91-100 SV9Z-PW10-A-J A-J SV9Z-PW10-K-T K-T SV9Z-PW10-U-Z U-Z Marking Plate Locking Lever Insert Relays & Sockets SV9Z-PW10 Signaling Lights Vertical Orientation Horizontal Orientation 6mm Marking Plate Placement Switches & Pilot Lights Marking Plate Part Numbers RV8H and RV8S SV9Z-PW10-GROUND SV9Z-PW10-AC 1. In place of insert orientation code: V=Vertical, H=Horizontal 2. Each unit has 10 pieces (marking plates). Timers Contactors Terminal Blocks Circuit Breakers 1705151135 800-262-IDEC (4332) * USA & Canada 847 Relays & Sockets Dimensions (mm) 6mm Electromechanical and Solid State Relay 35.0 88.0 69.6 74.2 35.0 93.4 6.1 14mm Electromechanical Relay 6.1 Timers 74.2 69.6 14mm Spring Clamp Terminal 69.6 14mm Screw Terminal 74.2 Relays & Sockets 6mm Spring Clamp Terminal 69.6 6mm Screw Terminal 74.2 Signaling Lights Switches & Pilot Lights RV8H and RV8S 35.0 93.4 14.0 14.0 Circuit Breakers Terminal Blocks Contactors 35.0 88.0 848 www.IDEC.com 1705151135 Relays & Sockets RV8H and RV8S Switches & Pilot Lights Internal Connections 6mm Electromechanical Relay DC AC/DC PROTECTION AND INDICATION CIRCUIT A1 A2 14 11(13+) 12 PROTECTION AND INDICATION CIRCUIT A1+ A2- 14 11(13+) 12 INPUT : AC120V,AC240V OUTPUT : DC24V A1 A2 INPUT : DC6V,DC24V OUTPUT : DC24V PROTECTION AND INDICATION CIRCUIT 14 13(13+) PROTECTION AND INDICATION CIRCUIT 14 13(13+) A2 14 13(13+) A1+ PROTECTION AND INDICATION CIRCUIT 14 13(13+) A2- PROTECTION AND INDICATION CIRCUIT 14 13(13+) INPUT : DC6V,DC24V OUTPUT : AC240V PROTECTION AND INDICATION CIRCUIT 14 13(13+) A1+ A2- Timers INPUT : AC120V,AC240V OUTPUT : AC240V A1 A2- PROTECTION AND INDICATION CIRCUIT Relays & Sockets A2 A1+ INPUT : DC6V,DC24V OUTPUT : DC48V INPUT : AC120V,AC240V OUTPUT : DC48V A1 Signaling Lights 6mm Solid State Relay 14mm Electromechanical Relay 1 Pole AC/DC A2 PROTECTION AND INDICATION CIRCUIT 14/24 11/21 12/22 A1+ A2- PROTECTION AND INDICATION CIRCUIT Contactors A1 DC 14/24 11/21 12/22 14mm Electromechanical Relay 2 Pole AC/DC A2 PROTECTION AND INDICATION CIRCUIT 1705151135 A1+ A2- PROTECTION AND INDICATION CIRCUIT 14 11 12 800-262-IDEC (4332) * USA & Canada 24 21 22 Circuit Breakers 14 11 12 24 21 22 Terminal Blocks A1 DC 849 Relays & Sockets Accessories Dimensions SV9Z-PW10* Marking Plate SV9Z-J20* Jumper for 6mm Relay 115.9 Cut 10.5 6.0 6.1 1.0 2.8 120.0 6.0 12.3 3.0 16.5 Switches & Pilot Lights RV8H and RV8S Signaling Lights 86.5 *Available blank or pre-marked. *Available in Black, Gray and Blue SV9Z-SA2W Spacer for 6 and 14mm Relay SV9Z-J232* Jumper for 14mm Relay 217.6 6.0 12.2 66.8 71.4 Relays & Sockets 222.2 12.3 15-P 14.0 2.8 *Available in black, gray and blue. 35.0 2.0 96.7 Timers Characteristics 6mm Electromechanical Relay Maximum Switching Power AC Maximum Switching Power DC AC Inductive load (p. f=0.35) Contact Current (A) Contact Current (A) Contactors AC Resistive load DC Resistive load DC Inductive load (L/R = 56ms) Contact Voltage (V) Circuit Breakers Terminal Blocks Contact Voltage (V) 850 www.IDEC.com 1705151135 Relays & Sockets 48V DC48V DC 24V DC24V DC 0.12 1.8 3.5 3.5 1.8 1.2 3.0 3.0 1.2 0.6 2.4 2.4 0.6 0.0 1.8 1.8 0.0 1.2 0 0.6 0.0 1.2 No air gapNo air gap Air gap 6.2 Air mm gap 6.2 mm No air gapNo air gap Air gap Air 6.2 gap mm 6.2 mm 0 10 1020 2030 0.6 0.0 0 3040 4050 5060 60 Ambient Ambient Temperature (C) Temperature (C) 0 10 10 20 20 30 30 40 40 50 Temperature AmbientAmbient Temperature (C) (C) 50 60 2.0 2.0 Load Current (Amperes) Load Current (Amperes) 1.3 2.3 2.3 1.3 1.0 2.0 2.0 1.0 0.7 1.7 1.7 0.7 0.3 1.3 1.3 0.3 0.0 1.0 0.7 0 0.3 0.0 Air gap 6.2 Air mm gap 6.2 mm No air gapNo air gap 1.0 0.0 Air gap Air 6.2 gap mm 6.2 mm 0 10 1020 2030 0.7 0.0 0 3040 4050 5060 60 Ambient Ambient Temperature (C) Temperature (C) Legend 0 10 10 20 0.02 0.02 0.00 0 3040 4050 5060 60 Ambient Ambient Temperature (C) Temperature (C) 0 10 10 20 20 30 30 40 40 50 50 60 60 2030 3040 4050 5060 60 50 60 60 Temperature AmbientAmbient Temperature (C) (C) 2.3 2.3 2.0 2.0 240V AC Random 240V AC Random Cross Cross No air gapNo air gap 0.3 0.04 20 30 30 40 40 50 50 60 60 1.7 1.7 1.3 2.3 2.3 1.3 1.0 2.0 2.0 1.0 0.7 1.7 1.7 0.7 0.3 1.3 1.3 0.3 0.0 1.0 0.7 0 0.3 0.0 1.0 0.0 0.7 No spacing required between Ambient units. Temperature (C) Spacing of 6.2mm minimum required between units Ambient Temperature (C) 1020 Ambient Ambient Temperature (C) Temperature (C) 0.3 0.0 0 0 10 Timers Load Current (Amperes) Load Current (Amperes) 1.7 0.06 0.00 240V AC Random Cross 240V ACCross Zero Cross 240V AC Zero 1.7 0.08 0.02 Relays & Sockets 2.3 0.10 0.04 0.08 0.12 0.06 No minimum No minimum air gap required air gap required 0.10 0.04 0.08 0.02 0.06 No minimum No minimum air gap required 0.00 air gap required 0 0.04 0 10 1020 2030 240V AC Random Cross Cross 240V AC Random 240V AC Zero Cross 2.3 0.12 0.06 0.00 60 240V AC Zero 240V ACCross Zero Cross 0.08 Load Current (Amperes) Load Current (Amperes) Load Current (Amperes) Load Current (Amperes) 4.0 2.4 48V DC Signaling Lights Load Current (Amperes) Load Current (Amperes) 3.024V DC3.0 Load Current (Amperes) Load Current (Amperes) 0.10 0.10 48V DC48V DC 24V DC24V DC 2.4 4.0 0.12 6mm Solid State Continuous Load Current vs. Ambient Temperature Curves Load Current (Amperes) Load Current (Amperes) 3.5 Load Current (Amperes) Load Current (Amperes) 4.0 3.5 Switches & Pilot Lights 4.0 RV8H and RV8S 0 10 10 20 20 30 30 40 40 50 Not Recommended Ambient Temperature (C) Ambient Temperature (C) Contactors Terminal Blocks Circuit Breakers 1705151135 800-262-IDEC (4332) * USA & Canada 851 Relays & Sockets 14mm Electromechanical Relays 14 mm Electrical Life Curve AC Load 1000 Operations (x10,000 operations) Signaling Lights Switches & Pilot Lights RV8H and RV8S 100 1 Pole 10 2 Pole Relays & Sockets 1 0 1 2 3 4 5 8 16 10 Contact Current (A) 14mm Contact Ratings AC DC 1 Pole 2 Pole 1 10 20 30 40 50 100 200 300 400 500 16 10 8 1 0.1 2 Pole 10 20 30 40 50 Contact Voltage (V) 100 200 300 400 500 Contact Voltage (V) Circuit Breakers Terminal Blocks Contactors 0.1 Contact Current (A) Contact Current (A) Timers 1 Pole 16 10 8 852 www.IDEC.com 1705151135