www.recom-power.com REV.: 9/2020 PA-4
AC/DC Converter
Specifications (measured @ Ta= 25°C, nominal input voltage (115/230VAC), full load and after warm-up)
RAC05-K
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Audio/Video, information and communication technology equipment - Safety
requirements E224736 UL62368-1, 2nd Edition: 2014
CSA C22.2 Nr. 62368-1-14, 2nd Edition: 2014
Information Technology Equipment, General Requirements for Safety (CB Scheme) E491408-A2-CB-1 IEC60950-1:2005, 2nd Edition: + A2:2013
Information Technology Equipment, General Requirements for Safety EN60950-1:2006 + A2:2013
Audio/Video, information and communication technology equipment - Safety
requirements (CB Scheme) OFF-4787889086-1
IEC62368-1:2014, 2nd Edition
Audio/Video, information and communication technology equipment - Safety
requirements EN62368-1: 2014 + A11:2017
EAC RU-AT.03.67361 TP TC 004/020, 2011
RoHS2+ RoHS 2011/65/EU + AM2015/863
EMC Compliance Conditions Standard / Criterion
Low-voltage power supplies DC output - Part 3: Electromagnetic compatibility EN61204-3: 2000, Class B
ESD Electrostatic discharge immunity test ±8kV Air; ±4kV Contact EN61000-4-2: 2009, Criteria B
Radiated, radio-frequency, electromagnetic field immunity test
10V/m, 80MHz-1GHz
3V/m, 1.5GHz-2GHz
1V/m, 2GHz-2.7GHz
EN61000-4-3: 2006 + A2, 2010, Criteria A
Fast Transient and Burst Immunity AC In Port: ±2.0kV EN61000-4-4: 2012, Criteria B
Surge Immunity AC In Port (L-N): ±1.0kV
DC Output Port: ±0.5kV EN61000-4-5: 2014, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields AC and DC Power Port: 10V EN61000-4-6: 2014, Criteria A
Power Magnetic Field Immunity 50Hz, 1A/m EN61000-4-8: 2010, Criteria A
Voltage Dips and Interruptions
Voltages Dips: >95%
Voltage Dips: 30%
Interruptions: >95%
EN61000-4-11: 2004, Criteria B
EN61000-4-11: 2004, Criteria C
EN61000-4-11: 2004, Criteria C
Voltage Fluctuations and Flicker in Public Low-Voltage Systems <=16A per phase EN61000-3-3: 2013
(5)
-25 -20 0 20 40 50 70
60 80 100
100
80
60
40
90
70
50
30
20
10
0
Ambient Temperature [°C]
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
80
60
40
90
70
50
30
20
10
0
Input Voltage [VAC]
85 90 110 135 160 185 210 235 264
Notes:
Note5: No derating required for the specified DC-input range
Notes:
Note6: If output is connected to GND, please contact RECOM tech support for advice
Line Derating