TS-1500 1500W True Sine Wave DC-AC Power Inverter series Features : True sine wave output (THD<3%) High surge power up to 3000W High efficiency up to 91% Power ON-OFF switch Standby saving mode can be selectable Front panel indicator for operation status Thermostatically controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. Optional monitoring software 3 years warranty SPECIFICATION MODEL TS-1500-112 RATED POWER (Typ.) TS-1500-124 TS-1500-148 TS-1500-212 E13 TS-1500-224 TS-1500-248 1500W MAXIMUM OUTPUT POWER (Typ.) 1725W for 180 sec. / 1875W for 10 sec. / surge power 3000W for 30 cycles OUTPUT AC VOLTAGE 100 / 110 / 115 / 120VAC selectable by setting button 200 / 220 / 230 / 240VAC selectable by setting button FREQUENCY 600.1Hz 500.1Hz WAVEFORM 50/60Hz selectable by setting button S.W AC REGULATION (Typ.) 3.0% SAVING MODE (Typ.) Default disabled. Load5W will be changed to standby mode FRONT PANEL INDICATOR Battery voltage level, output load level, saving mode, fault and operation status BAT. VOLTAGE 12V 24V 48V 12V 24V 48V 42 ~ 60VDC 37.5A 10.5 ~ 15VDC 150A 21 ~ 30VDC 42 ~ 60VDC 75A 37.5A 89% Open & sealed Lead Acid 89% 88% 90% 91% 40A*5 11.34% 30A*3 22.54% 30A*2 454% 40A*5 11.34% 30A*3 22.54% 30A*2 454% 10.54% 214% 424% 10.54% 214% 424% 82 5 96 5 68 5 68 5 68 5 VOLTAGE RANGE (Typ.)Note.3,6 10.5 ~ 15VDC DC CURRENT (Typ.) Note.5 150A INPUT 50/60Hz selectable by setting button S.W Note.2 True sine wave (THD<3%) 21 ~ 30VDC 75A 18W @ standby saving mode NO LOAD DISSIPATION OFF MODE CURRENT DRAW 1mA EFFICIENCY (Typ.) Note.2 87% BATTERY TYPES FUSE BATTERY BAT. LOW ALARM INPUT PROTECTION BAT. LOW SHUTDOWN REVERSE POLARITY By internal fuse open 82 5 OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power transistor OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 125% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover GFCI PROCTECTION ENVIRONMENT WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY VIBRATION SAFETY STANDARDS LVD SAFETY & WITHSTAND VOLTAGE EMC EMC EMISSION EMC IMMUNITY CONTROL WIRING OTHERS NOTE UL458 (only for "GFCI" receptacle-Type F ) DIMENSION PACKING None Note.1 0 ~ +40 @ 100% load ; 60 @ 50% load 20% ~ 90% RH non-condensing -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes UL458 (only for "GFCI" receptacle-Type F ) None None Bat I/P - AC O/P:3.0KVAC EN60950-1 AC O/P - FG:1.5KVAC Compliance to FCC class A None Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN61000-4-2,3,8 RJ11 -RS232 (Option) 420*220*88mm (L*W*H) 6.81Kg; 2pcs/14.6Kg/1.61CUFT 1.Output derating capacity referenced by curve 1. 2.THD and Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage. 3.Input derating capacity referenced by curve 2. 4.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting. 5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage. 6.The tolerance of each voltage value by models is:112/2120.5V;124/2241V;148/2482V File Name:TS-1500-SPEC 2015-05-27 TS-1500 1500W True Sine Wave DC-AC Power Inverter TS 1500 112 A A :TYPE A OUTLET B :TYPE B OUTLET C :TYPE C OUTLET D :TYPE D OUTLET E :TYPE E OUTLET F :TYPE F OUTLET 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC TS:True sine wave inverter Output: O/P Wattage:1500W series 1:110VAC 2:230VAC AC Output Receptacles (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F USA EUROPE AUSTRALIA U.K JAPAN GFCI Country E13 Certificate E13 E13 (Expect for 48V input) Derating Curve Mechanical Specification Unit:mm 100 LOAD (%) 11.05 80 Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) Inverter Inverter Chassis Ground Inverter 60 40 20 Inverter ENG DC INPUT POS WARNING: Reverse Polarity Will Damage The 0 10 20 30 40 50 60 70 AMBIENT TEMPERATURE () CURVE 1 48 12.1 Air flow direction 100 LOAD (%) 108.4 80 60 40 10 20 7 10.5VDC 21VDC 42VDC 11.5VDC 23VDC 46VDC 15VDC 30VDC 60VDC (HORIZONTAL) BATTERY INPUT VOLTAGE (V) CURVE 2 203.2 420 27.45 57.75 36.25 15.6 AC OUTPUT ON BATTERY Setting LOAD OFF 100 100 INVERTER On 0 0 Bat Low Saving Remote port Type-A AC OUTPUT ON BATTERY Setting LOAD OFF 100 100 INVERTER On 0 0 Bat Low Saving Remote port 207 220 Type-B File Name:TS-1500-SPEC 2015-05-27 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Mean Well: TS-1500-148F TS-1500-124F TS-1500-112F TS-1500-112A TS-1500-124A TS-1500-148A TS-1500-212B TS1500-224B TS-1500-248B