OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A 09/08
Page 1 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Description:
All components in this series include a photodiode, amplifier, voltage regulator, Schmitt trigger and NPN output
transistor on a single silicon chip. OPL560 chips also include a voltage regulator on the chip. All devices in the
series have a Photologic® chip that is encapsulated in a molded plastic side-looking package with an integral lens
(recessed integral lens for OPL535 and OPL536). This packaging provides enhanced optical coupling, combined
with mechanical protection. The hysteresis characteristics of the Schmitt trigger on each device offers high
immunity to noise on input and VCC.
OPL530, OPL531, OPL535 and OPL536 include a 10 K pull-up resistor (RL) from output to VCC. These
components exhibit very stable performance over supply voltages ranging from 4.5 V to 16 V and a wide range of
irradiance levels. OPL550 and OPL551 devices feature TTL/LSTTL compatible logic level output which can drive
up to 8 TTL loads without additional circuitry and medium-speed data rates to 250 kBaud, with typical rise and fall
times of 25 nanoseconds. OPL560, OPL561, OPL562 and OPL563 devices feature TTL/LSTTL compatible logic
level output which can drive up to 10 TTL loads over supply voltages ranging from 4.5 V to 16 V.
OPL530, OPL531, OPL550, OPL551, OPL560, OPL561, OPL562 and OPL563 are mechanically and spectrally
matched to OP140 and OP240 LEDs. OPL535 and OPL536 are mechanically and spectrally matched to OP145
and OP245 series LEDs.
Features:
Choice of four output options in low-cost side-looking package
Choice of two sensitivity options (OPL560/561/562/563)
High noise immunity
Direct TTL/LSTTL CMOS interface
Data rates to 250 kBaud for all except OPL560 series (200 kBaud)
Low power consumption
Product Photo Here
Applications:
Non-contact reflective
object sensor
Assembly line automation
Machine automation
Machine safety
End of travel sensor
Door sensor
Base Part Number
Package
Output Type - with Light
Input Power Range
(mW/cm2) [Min/Max]
- A B
OPL530
Recessed
Lens
Internal 10K - High
0.08/.40 0.08/.25
0.20/0.40
OPL531 Internal 10K - Low
OPL535 Internal 10K - High
OPL536 Internal 10K - Low
OPL550 Totem Pole - High 0.25/2.4 0.25/1.4
OPL551 Totem Pole - Low 0.25/2.5 0.25/1.5
OPL560 Totem Pole - High
0.09/.55 0.09/.36
OPL561 Totem Pole - Low
OPL562 Totem Pole - High
0.025/.23 0.025/.14
OPL563 Totem Pole - Low
OC = Open Collector Output
RoHS
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A 09/08
Page 2 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPL530, OPL550, OPL560 Series
OPL535, OPL536 Series
Pin # Sensor
1 Ground
2 Output
3 VCC
Pin # Sensor
1 Ground
2 Output
3 VCC
DIMENSIONS ARE IN: [ MILLIMETERS]
INCHES
DIMENSIONS ARE IN: [ MILLIMETERS]
INCHES
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A 09/08
Page 3 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551, OPL56 0, OPL561, OPL562, OPL563 (-OC, -OCA, -OCB)
OPL550, OPL550A, OPL551, OPL551A,
OPL560, OPL560A, OPL561, OPL561A, OPL562, OPL562A, OPL563, OPL563A
VCC
OUT
GND
VCC
OUT
GND
VCC
OUT
GND
VCC
OUT
GND
OPL550/550A/560/560A/562/562A Totem-Pole
OPL 551/551A/561/561A/563/563A/ Inverted Totem-Pole OPL 531/536/551/561/563 (-OC, -OCA, -OCB) Inverted Open-Collector
OPL530/535/550/560/562 (-OC, -OCA, -OCB) Open-Collector
OPL530, OPL530A, OPL530B, OPL531, OPL531A, OPL531B
OPL535, OPL535A, OPL535B, OPL536, OPL536A, OPL536B
VCC
OUT
GND
VCC
OUT
GND
VCC
OUT
GND
VCC
OUT
GND
OPL530/530A/530B, OPL535/535A/535B 10K Pull-Up OPL531/531A/531B, OPL536/536 A/536B Inverted 10K Pull-Up
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A 09/08
Page 4 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 K.
Absolute Maximum Ratings (TA=25°C unless otherwise noted)
Input Diode
Supply Voltage (VCC)
OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536, OPL536-OC,
OPL550, OPL551
OPL560, OPL561, OPL562, OPL563
18 V
10 V
18 V
Operating Temperature Range -40° C to + 85° C
Storage Temperature Range -40° C to + 100° C
Lead Soldering Temperature [1/16 inch (1.6mm) from the case for 5 sec. with soldering iron] 260°C
Power Dissipation
OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536, OPL536-OC
OPL550, OPL551, OPL560, OPL561, OPL562, OPL563
90 mW
200 mW(2)
Sinking Current
OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536, OPL536-OC
OPL550, OPL551
OPL560, OPL561, OPL562, OPL563
50 mA
-
50 mA
Voltage at Output Lead (4)
OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536, OPL536-OC
OPL550-OC, OPL551-OC
OPL560-OC, OPL561-OC, OPL562-OC, OPL563-OC
35 V
35 V
35 V
Duration of Output Short to VCC or Ground
OP550, OP551
1 second
Duration of Output Short to VCC
OPL550-OC, OPL551-OC
OPL560, OPL561, OPL562, OPL563, OPL560-OC, OPL561-OC, OPL562-OC, OPL563-OC
1 second
1 second
Low Level Output Current
OPL550, OPL551 Series
16 mA
High Level Output Current
OPL550, OPL551 Series 1 mA
Irradiance
OPL550, OPL551 Series
OPL560, OPL560-OC, OPL561, OPL561-OC
OPL562, OPL562-OC, OPL563, OPL563-OC
10 mW/cm2
9 mW/cm
3 mW/cm2
Sourcing Current
OPL560, OPL561, OPL562, OPL563
10 mA
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A 09/08
Page 5 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 K.
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
VCC
Operating Supply Voltage
OPL530, OPL530-OC, OPL531, OPL531-OC
OPL535, OPL535-OC, OPL536, OPL536-OC,
OPL560, OPL561 Series
OPL550, OPL551 Series
4.5
4.5
-
-
16
5.5
V
V
-
-
Peak-to-Peak VCC Ripple Necessary to Cause
False Triggering of Output
OPL530, OPL530-OC, OPL531, OPL531-OC
OPL535, OPL535-OC, OPL536, OPL536-OC
OPL560, OPL561 Series
OPL550, OPL551 Series
-
-
-
2
2
-
V
V
f = DC to 50 MHz
VCC = 5 V DC, f = DC to 50 MHz
ICC
Supply Current(4)
OPL530, OPL530-OC, OPL531, OPL531-OC
OPL535, OPL535-OC, OPL536, OPL536-OC
OPL550, OPL551 Series
OPL560, OPL561 Series
-
-
-
2.7
8
8
5
15
12
mA
mA
mA
EE = 0 or 1 mW/cm2
EE = 0 or 3 mW/cm2, VCC = 5.5 V
EE = 0 or 1 mW/cm2
EeT(+)
Positive-Going Threshold Irradiance(3)
OPL530, OPL530-OC, OPL531, OPL531-OC
OPL535, OPL535-OC, OPL536, OPL536-OC
OPL530A, OPL530-OCA, OPL531A, OPL531-OCA
OPL535A, OPL535-OCA, OPL536A, OPL536-OCA
OPL530B, OPL530-OCB, OPL531B, OPL531-OCB
OPL535B, OPL535-OCB, OPL536B, OPL536-OCB
OPL550, OPL550-OC, OPL551, OPL551-OC
OPL550A, OPL550-OCA, OPL551, OPL551-OCA
0.08
0.08
0.12
.25
.25
-
-
-
-
-
0.40
0.25
0.40
2.4
1.4
mW/cm2
mW/cm2
mW/cm2
mW/cm2
mW/cm2
TA = 25° C
TA = 25° C
TA = 25° C
VCC = 5 V, TA = 25° C
VCC = 5 V, TA = 25° C
EeT(+)/EeT(-)
Hysteresis Ratio
OP530, OP531 Series
OP535, OP536 Series
OPL550, OPL551 Series
OPL560, OPL561 Series
1.05
1.05
1.50
1.20
1.3
1.2
2
1.55
1.6
1.5
2.5
2
-
-
-
-
-
-
-
-
Eet(+)
(T)
Temperature Co-efficient
OPL530, OPL530-OC, OPL531, OPL531-OC
OPL535, OPL535-OC, OPL536, OPL536-OC
-
-
-0.6
-1.6
-
-
%/°C
%/°C
>0°C
<0°C
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A 09/08
Page 6 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 K.
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
VOH
Operating Supply Voltage
OPL550
OPL551
OPL560
OPL561
2.4
2.4
VCC -2.1
VCC -2.1
3.3
3.3
-
-
-
-
-
-
V
V
V
V
VCC = 4.5 V, IOH = -800 µa,
EE = 3 mW/cm2
VCC = 4.5 V, IOH = -800 µa,
EE = 0
IOH = -1 µA, EE = 1 mW/cm2
IOH = -1 µA, EE = 0
VOL
Low Level Output Voltage
OPL530, OPL530-OC, OPL535, OPL535-OC
OPL531, OPL531-OC, OPL536, OPL536-OC
OPL550
OPL551
OPL560, OPL560-OC
OPL561, OPL561-OC
-
-
-
-
-
-
0.2
0.2
0.25
0.25
-
-
0.4
0.4
0.4
0.4
.4
.4
V
V
V
V
V
V
IOL = 16 mA, EE = 0
IOL = 16 mA, EE = 1 mW/cm2
VCC = 4.5 V, IOL = 12.8 mA,
EE = 0
VCC = 4.5 V, IOL = 12.8 mA,
EE = 3 mW/cm2
IOL = 16 mA, EE = 0
IOL = 16 mA, EE = 1 mW/cm2
IOS
Short Circuit Output Current
OPL550
OPL551
-20
-20
-55
-55
-100
-100
mA
mA
VCC = 5.5 V, Output = GND,
EE = 3 mW/cm2
VCC = 5.5 V, Output = GND,
EE = 0
IOH
High Level Output Current(4)
OPL531, OPL531-OC, OPL536, OPL536-OC
OPL535, OPL535-OC, OPL530, OPL530-OC
OPL550-OC
OPL551-OC
OPL560-OC
OPL561-OC
-
-
-
-
-
-
0.1
0.1
1
1
-
-
10
10
100
100
100
100
µA
µA
µA
µA
µA
µA
VOH = 30 V, EE = 0
VOH = 30 V, EE = 1 mW/cm2
VCC = 4.5 V, VOH = 30 V,
EE = 3 mW/cm2
VCC = 4.5 V, VOH = 30 V,
EE = 0
VOH = 30 V, EE = 1 mW/cm2
VOH = 30 V, EE = 0
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A 09/08
Page 7 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 K.
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
tr
Output Rise Time
OPL530, OPL531, OPL535, OPL536
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
OPL550, OPL551
OPL550-OC, OPL551-OC
OPL560, OPL561
OPL560-OC, OPL561-OC
-
-
-
-
-
-
1.5
50
25
25
-
-
-
-
70
70
70
100
µs
ns
ns
ns
ns
µs
EE = 0 or 1 mW/cm2, CL = 50 pF
EE = 0 or 1 mW/cm2, RL = 300 to
5 V, CL = 50 Pf
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, f = 10 kHz, DC = 50%
RL = 8 TTL loads
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, f = 10 kHz, DC = 50%,
RL = 360
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz, DC = 50%,
RL = 360
tr
Output Rise Time
OPL530, OPL531, OPL535, OPL536
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
OPL550-OC, OPL551-OC
OPL560-OC, OPL561-OC
OPL560, OPL561
OPL560-OC, OPL561-OC
-
-
-
-
-
-
-
-
25
-
-
-
-
-
70
70
70
100
µs
ns
ns
ns
ns
ns
EE = 0 or 1 mW/cm2, CL = 50 pF
EE = 0 or 1 mW/cm2, RL = 300 to
5 V, CL = 50 pF
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 8 TTL loads,
f = 10 kHz, DC = 50%
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 8 TTL loads,
f = 10 kHz, DC = 50%
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
tf
Output Fall Time
OPL530, OPL531, OPL535, OPL536
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
OPL550-OC, OPL551-OC
OPL560, OPL561
OPL560-OC, OPL561-OC
-
-
-
-
-
20
20
25
-
-
-
-
70
70
100
ns
ns
ns
ns
ns
EE = 0 or 1 mW/cm2, CL = 50 Pf
EE = 0 or 1 mW/cm2, RL = 300 to
5 V, CL = 50 pF
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 360 , f = 10 kHz,
DC = 50%
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A 09/08
Page 8 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
tPLH, TPHL
Propagation Delay (Low-High/High-Low)
OPL560, OPL561
OP560-OC, OPL561-OC
-
-
5
5
-
-
µs
µs
DC = 50%, RL = 10 TTL Loads
DC = 50%, RL = 300
tpEeT(-)
Propagation Delay
OPL530, OPL531, OPL535, OPL536,
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
OPL550-OC, OPL551-OC
-
-
3.0
2.5
-
5
µs
µs
EE= 0 or 1 mW/cm2, RL = 300 to
5V, CL = 50 pF
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 360 , f = 10 kHz,
DC = 50%
tpEeT(+)
Propagation Delay
OPL530, OPL531, OPL535, OPL536
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
OPL550-OC, OPL551-OC
-
-
-
1.0
1.0
2.5
-
-
5
µs
µs
µs
EE = 0 or 1 mW/cm2, RL = 300 to
5 V, CL = 50 pF
EE = 0 or 1 mW/cm2, RL = 300 to
5 V, CL = 50 pF
VCC = 5 V, TA = 25° C,
EE = 0 or 3 mW/cm2, RL = 8 TTL
loads, f = 10 kHz, DC = 50%
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 K.