OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747 FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A 09/08
Page 7 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 KΩ.
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
tr
Output Rise Time
OPL530, OPL531, OPL535, OPL536
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
OPL550, OPL551
OPL550-OC, OPL551-OC
OPL560, OPL561
OPL560-OC, OPL561-OC
-
-
-
-
-
-
1.5
50
25
25
-
-
-
-
70
70
70
100
µs
ns
ns
ns
ns
µs
EE = 0 or 1 mW/cm2, CL = 50 pF
EE = 0 or 1 mW/cm2, RL = 300 Ω to
5 V, CL = 50 Pf
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, f = 10 kHz, DC = 50%
RL = 8 TTL loads
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, f = 10 kHz, DC = 50%,
RL = 360 Ω
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz, DC = 50%,
RL = 360 Ω
tr
Output Rise Time
OPL530, OPL531, OPL535, OPL536
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
OPL550-OC, OPL551-OC
OPL560-OC, OPL561-OC
OPL560, OPL561
OPL560-OC, OPL561-OC
-
-
-
-
-
-
-
-
25
-
-
-
-
-
70
70
70
100
µs
ns
ns
ns
ns
ns
EE = 0 or 1 mW/cm2, CL = 50 pF
EE = 0 or 1 mW/cm2, RL = 300 Ω to
5 V, CL = 50 pF
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 8 TTL loads,
f = 10 kHz, DC = 50%
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 8 TTL loads,
f = 10 kHz, DC = 50%
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
tf
Output Fall Time
OPL530, OPL531, OPL535, OPL536
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
OPL550-OC, OPL551-OC
OPL560, OPL561
OPL560-OC, OPL561-OC
-
-
-
-
-
20
20
25
-
-
-
-
70
70
100
ns
ns
ns
ns
ns
EE = 0 or 1 mW/cm2, CL = 50 Pf
EE = 0 or 1 mW/cm2, RL = 300 Ω to
5 V, CL = 50 pF
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 360 Ω, f = 10 kHz,
DC = 50%
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz