DF-S
Current
1.0 Amp. at 40ºC
Voltage
600 V to 1000 V
MECHANICAL DATA
DFS

Ideal for automated placement
TYPICAL APPLICATIONS
Used in ac-to-dc bridge full wave rectification for SMPS,
lighting ballaster, adapter, battery charger, home appliances, office
equipment, and telecommunication applications..
FEATURES
High forward surge current capability
Solder dip 260ºC, 10s
Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
Meets MSL level 1, per J-STD-020, LF maximum
peak of 250º C
Maximun Ratings and Electrical Characteristics at 25°C
1.0 Amp. Miniature Glass Passivated Single-Phase Surface Mount Bridge Rectifier
VF
Max. forward voltage drop per element at I
F
= 1 A
IR
Max. reverse current per
element V
RRM
d.c.
Rthj-a
(*) NOTE: Thermal Resistance from junction to ambient PCB mounted P.C. Board with 12 mm. sq. Copper
and Ta = 125 °C
and Ta = 25 °C
Peak recurrent reverse voltage (V)
Maximum RMS voltage (V)
Forward current at Tamb = 40 °C
VRRM
VRMS
IF (AV)
Tj
Tstg
Operating temperature range
Storage temperature range  55 to + 150 °C
IFSM 8.3 ms. peak forward surge current
(Jedec Method)
1.0 A
50 A
 55 to + 150 °C
800
560
DF08S
1.1 V
10 µA
500 µA
65 °C/W
Marking code DF08S
Maximum thermal resistance junction to ambient (*)
DF06S DF10S
600
420
DF06S
1000
700
DF10S
R Load
C Load 0.8 A
I2t
I
2
t value for fusing (t = 8.3 ms)
10 A2sec
Electrical Characteristics at Tamb = 25 °C
www.fagorelectronica.com
Document Name: dfs Version: Mar-12
Page Number: 1/4

Case: DFS

Polarity: As marked on body.

Terminals:
Matte tin plated leads, solderable per
MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102.
Consumer grade, meets JESD 201 class 1A whisker test.
Epoxy meets UL 94V-0 flammability rating.
Package Outline Dimensions
:
(mm)
DF-S
1.0 Amp. Miniature Glass Passivated Single-Phase Surface Mount Bridge Rectifier
Ordering information
TR 13" diameter tape and reel 1,500 0.399
DFS
DF06S TR
www.fagorelectronica.com
Document Name: dfs Version: Mar-12
Page Number: 2/4
PREFERRED P/N PACKAGE CODE DELIVERY MODE BASE QUANTITY UNIT WEIGHT (g)
Mounting Pad Layout
Marking code
0.33
0.22
10.3
9.8
6.5
6.2
0.33
0.076
1.53
1.02
8.51
8.13
45°
3.3
3.05
5.2
5
1.2
1.02
MC
Week code
Year code
WWY
1.2
5.1
8.7
1.52
DF-S
Ratings and Characteristics (Ta 25 ºC unless otherwise noted)
1.0 Amp. Miniature Glass Passivated Single-Phase Surface Mount Bridge Rectifier
VF, instantaneous forward voltage (V)
IF, instantaneous forward current (A)
0 0.6 0.8
0 25 50 75 100 125 175150
TL, lead temperature (ºC)
10 100
IFSM, peak forward surge current (A)
MAXIMUM NON-REPETITIVE
PEAK FORWARD SURGE CURRENT
Number of cycles at 60 Hz.
TYPICAL FORWARD CHARACTERISTIC FORWARD CURRENT DERATING CURVE
IF(AV), average forward rectified current (A)
101
1.2
0.6
0.2
0
21
0.2 0.4
100
10
1.0 1.6
20
1.2 1.4
100
10-1
10-2
1
0.8
0.4
50
4 6 20 40
R or L Load
C - Load
www.fagorelectronica.com
Document Name: dfs Version: Mar-12
Page Number: 3/4
DF-S
Disclaimer
1.0 Amp. Miniature Glass Passivated Single-Phase Surface Mount Bridge Rectifier
www.fagorelectronica.com
Document Name: dfs Version: Mar-12
Page Number: 4/4
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.